High-resolution microPET imaging of carcinoembryonic antigen-positive xenografts by using a copper-64-labeled engineered antibody fragment
Open accessThe DOI matches its Crossref record.
Abstract
Rapid imaging by antitumor antibodies has been limited by the prolonged targeting kinetics and clearance of labeled whole antibodies. Genetically engineered fragments with rapid access and high retention in tumor tissue combined with rapid blood clearance are suitable for labeling with short-lived radionuclides, including positron-emitting isotopes for positron-emission tomography (PET). An engineered fragment was developed from the high-affinity anticarcinoembryonic antigen (CEA) monoclonal antibody T84.66. This single-chain variable fragment (Fv)-C H 3, or minibody, was produced as a bivalent 80 kDa dimer. The macrocyclic chelating agent 1,4,7,10-tetraazacyclododecane- N,N′,N′′, N′′′ -tetraacetic acid (DOTA) was conjugated to the anti-CEA minibody for labeling with copper-64, a positron-emitting radionuclide ( t 1/2 = 12.7 h). In vivo distribution was evaluated in athymic mice bearing paired LS174T human colon carcinoma (CEA positive) and C6 rat glioma (CEA negative) xenografts. Five hours after injection with 64 Cu-DOTA-minibody, microPET imaging showed high uptake in CEA-positive tumor (17.9% injected dose per gram ± 3.79) compared with control tumor (6.0% injected dose per gram ± 1.0). In addition, significant uptake was seen in liver, with low uptake in other tissues. Average target/background ratios relative to neighboring tissue were 3–4:1. Engineered antibody fragments labeled with positron-emitting isotopes such as copper-64 provide a new class of agents for PET imaging of tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216
Self-citationMolecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656
Self-citationFass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Bartlett, D. W., Su, H., Hildebrandt, I. J., Weber, W. A., & Davis, M. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707461104 · Cited by 803
Overcoming the Blood–Brain Barrier: The Role of Nanomaterials in Treating Neurological Diseases
Furtado, D., Björnmalm, M., Ayton, S., Bush, A. I., Kempe, K., & Caruso, F. (2018) · Advanced Materials · doi:10.1002/adma.201801362 · Cited by 708
ImmunoPET: Concept, Design, and Applications
Wei, W., Rosenkrans, Z. T., Liu, J., Huang, G., Luo, Q.-Y., & Cai, W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00738 · Cited by 484
Radiometals for Combined Imaging and Therapy
Cutler, C. S., Hennkens, H. M., Sisay, N., Huclier-Markai, S., & Jurisson, S. S. (2013) · Chemical Reviews · doi:10.1021/cr3003104 · Cited by 395
Antibody-targeted radiation cancer therapy
Milenic, D. E., Brady, E. D., & Brechbiel, M. W. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1413 · Cited by 380
“Production and availability questions currently compromise 67 Cu, and so 64 Cu might eventually be judged to be more viabl”
BackgroundOdyssey of a cancer nanoparticle: From injection site to site of action
Nichols, J. W., & Bae, Y. H. (2012) · Nano Today · doi:10.1016/j.nantod.2012.10.010 · Cited by 364
Borsi, L., Balza, E., Bestagno, M., Castellani, P., Carnemolla, B., Biro, A., Leprini, A., Sepulveda, J., Burrone, O., Neri, D., et al. (2002) · International Journal of Cancer · doi:10.1002/ijc.10662 · Cited by 355
Does a targeting ligand influence nanoparticle tumor localization or uptake?
Pirollo, K. F., & Chang, E. H. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.06.007 · Cited by 347
Immuno-PET: A Navigator in Monoclonal Antibody Development and Applications
van Dongen, G. A. M. S., Visser, G. W. M., Lub-de Hooge, M. N., de Vries, E. G., & Perk, L. R. (2007) · The Oncologist · doi:10.1634/theoncologist.12-12-1379 · Cited by 330
Performance evaluation of the microPET P4: a PET system dedicated to animal imaging
Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/308 · Cited by 308
Nanotechnology applied to overcome tumor drug resistance
Gao, Z., Zhang, L., & Sun, Y. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.05.051 · Cited by 303
Use of Positron Emission Tomography in Animal Research
Cherry, S. R., & Gambhir, S. S. (2001) · ILAR Journal · doi:10.1093/ilar.42.3.219 · Cited by 284
Self-citationTai, Y.-C., Chatziioannou, A. F., Yang, Y., Silverman, R. W., Meadors, K., Siegel, S., Newport, D. F., Stickel, J. R., & Cherry, S. R. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/303 · Cited by 273
Molecular imaging of small animals with dedicated PET tomographs
Chatziioannou, A. F. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0683-3 · Cited by 265
Development of radioimmunotherapeutic and diagnostic antibodies: an inside-out view
Boswell, C. A., & Brechbiel, M. W. (2007) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2007.04.001 · Cited by 241
Stasiuk, G. J., & Long, N. J. (2013) · Chemical Communications · doi:10.1039/c3cc38507h · Cited by 223
Cooper, M. S., Ma, M. T., Sunassee, K., Shaw, K. P., Williams, J. D., Paul, R. L., Donnelly, P. S., & Blower, P. J. (2012) · Bioconjugate Chemistry · doi:10.1021/bc300037w · Cited by 217
A critical review of lipid-based nanoparticles for taxane delivery
Feng, L., & Mumper, R. J. (2013) · Cancer Letters · doi:10.1016/j.canlet.2012.07.006 · Cited by 191
Multivalent antibodies: when design surpasses evolution
Cuesta, Á. M., Sainz-Pastor, N., Bonet, J., Oliva, B., & Álvarez-Vallina, L. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.03.007 · Cited by 186
Dimeric and trimeric antibodies: high avidity scFvs for cancer targeting
Kortt, A. A., Dolezal, O., Power, B. E., & Hudson, P. J. (2001) · Biomolecular Engineering · doi:10.1016/s1389-0344(01)00090-9 · Cited by 173
Robinson, M. K., Doss, M., Shaller, C., Narayanan, D., Marks, J. D., Adler, L. P., González Trotter, D. E., & Adams, G. P. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-2008 · Cited by 169
“(10) validated these predictions in preclinical imaging studies done on a dedicated small animal imager (microPET) with an antiCEA minibody labeled with (64)Cu ((64)Cu-DOTA-T84.”
BackgroundViola-Villegas, N., & Doyle, R. P. (2009) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2009.03.013 · Cited by 167
Engineered antibody fragments for immuno-PET imaging of endogenous CD8 + T cells in vivo
Tavaré, R., McCracken, M. N., Zettlitz, K. A., Knowles, S. M., Salazar, F. B., Olafsen, T., Witte, O. N., & Wu, A. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316922111 · Cited by 166
Self-citationSprague, J. E., Peng, Y., Sun, X., Weisman, G. R., Wong, E. H., Achilefu, S., & Anderson, C. J. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1084 · Cited by 158
Metadata
- Authors
- Wu, A. M., Yazaki, P. J., Tsai, S.-W., Nguyen, K., Anderson, A.-L., McCarthy, D. W., Welch, M. J., Shively, J. E., Williams, L. E., Raubitschek, A. A., Wong, J. Y. C., Toyokuni, T., Phelps, M. E., & Gambhir, S. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-07-04
- Volume
- 97
- Issue
- 15
- Pages
- 8495-8500
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2161362011
- Cited by
- 214
- References
- 0
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.