Electrochemical detection of a single cytomegalovirus at an ultramicroelectrode and its antibody anchoring
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Significance: The need for rapid, dependable, and sensitive detection of biological threats is ever increasing. Relatively arduous techniques, with varying degrees of sensitivity, exist for the detection of pathogens, including ELISA, electrogenerated chemiluminescence methods, sensitive PCR techniques, culturing, and microscopy. Here, we extend the observation of particle collisions on ultramicroelectrodes to murine cytomegalovirus. We further present an electrochemical technique for the specific detection of low concentrations of a virus by observing the effect of virus and antibody-specific polystyrene bead binding. This work, in principle, provides a framework for the detection of any biologically relevant antigen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In the following years, this method has been widely extended to the detection of various micro-and nano-objects, with a specific interest in single collisions of bio-entities such as proteins, viruses, and bacteria [19,25,29,35].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Einstein, A. (1905) · Annalen der Physik · doi:10.1002/andp.19053220806 · Cited by 8,265
A DNA-based method for rationally assembling nanoparticles into macroscopic materials
Mirkin, C. A., Letsinger, R. L., Mucic, R. C., & Storhoff, J. J. (1996) · Nature · doi:10.1038/382607a0 · Cited by 6,683 · cited 1×
“Letsinger and coworkers, who observed the color change of a gold colloidal system when the gold NPs were functionalized with cDNA oligomers, have used this anchoring approach as an ensemble technique (33, 34).”
MethodDollard, S. C., Grosse, S. D., & Ross, D. S. (2007) · Reviews in Medical Virology · doi:10.1002/rmv.544 · Cited by 1,257 · cited 1×
“Moreover, HCMV congenital infection is a leading cause of birth defects and developmental disabilities including hearing and vision loss, microcephaly, and cognitive disabilities (25).”
BackgroundObserving Single Nanoparticle Collisions at an Ultramicroelectrode by Electrocatalytic Amplification
Xiao, X., & Bard, A. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja072344w · Cited by 704 · cited 3×
“The interested reader can consult the references for a discussion on each of the techniques used to observe stochastic events electrochemically: blocking (9, 13), electrocatalytic amplification (1), open circuit potential (16), droplet blocking/reactor (13, 14), and ECL (15, 17,18).”
BackgroundMethodSelf-citationElectrogenerated Chemiluminescence
(2004) · CRC Press eBooks · doi:10.1201/9780203027011 · Cited by 702
DNA-Directed Synthesis of Binary Nanoparticle Network Materials
Mucic, R. C., Storhoff, J. J., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982721s · Cited by 678 · cited 2×
“Letsinger and coworkers, who observed the color change of a gold colloidal system when the gold NPs were functionalized with cDNA oligomers, have used this anchoring approach as an ensemble technique (33, 34).”
MethodResultThe pathogenesis of human cytomegalovirus
Griffiths, P., Baraniak, I., & Reeves, M. (2015) · The Journal of Pathology · doi:10.1002/path.4437 · Cited by 592 · cited 1×
“However, immunocompromised individuals infected with human cytomegalovirus (HCMV) are at a significantly greater risk of morbidity and mortality (24), including patients receiving chemotherapeutics, AIDS patients, and organ transplant recipients.”
BackgroundThe Electrochemical Detection and Characterization of Silver Nanoparticles in Aqueous Solution
Zhou, Y., Rees, N. V., & Compton, R. G. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201100885 · Cited by 536
Entry of herpesviruses into mammalian cells
Heldwein, E. E., & Krummenacher, C. (2008) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-008-7570-z · Cited by 355 · cited 1×
“Glycoprotein B (gB), one of the major envelope glycoproteins in herpesviruses, functions to facilitate attachment to host cell receptors and mediate fusion of the viral envelope with the host cell membrane (30).”
BackgroundA Nanoengineering Approach for Investigation and Regulation of Protein Immobilization
Tan, Y. H., Liu, M., Nolting, B., Go, J. G., Gervay-Hague, J., & Liu, G.-Y. (2008) · ACS Nano · doi:10.1021/nn800508f · Cited by 312
Cited by
Electrode–particle impacts: a users guide
Sokolov, S. V., Eloul, S., Kätelhön, E., Batchelor-McAuley, C., & Compton, R. G. (2017) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp07788a · Cited by 224
Observation of Single-Protein and DNA Macromolecule Collisions on Ultramicroelectrodes
Dick, J. E., Renault, C., & Bard, A. J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04545 · Cited by 215
Self-citationElectrochemistry under confinement
Jaugstetter, M., Blanc, N., Kratz, M., & Tschulik, K. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00789k · Cited by 159
Electrochemical Detection of Single Phospholipid Vesicle Collisions at a Pt Ultramicroelectrode
Lebègue, E., Anderson, C. M., Dick, J. E., Webb, L. J., & Bard, A. J. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b03123 · Cited by 137
Self-citationEmerging tools for studying single entity electrochemistry
Wang, Y., Shan, X., & Tao, N. J. (2016) · Faraday Discussions · doi:10.1039/c6fd00180g · Cited by 137
Metadata
- Authors
- Dick, J. E., Hilterbrand, A. T., Boika, A., Upton, J. W., & Bard, A. J.
- Affiliations
- The University of Texas at Austin (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2015-04-13
- Volume
- 112
- Issue
- 17
- Pages
- 5303-5308
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC4418878
- OpenAlex
- W1990065445
- Cited by
- 166
- References
- 44
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 10 · 2023: 21 · 2022: 13 · 2021: 17 · 2020: 10 · 2019: 22 · 2018: 16 · 2017: 16 · 2016: 24 · 2015: 5
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- cytomegalovirus, ultramicroelectrodes, virus detection, viral glycoproteins, collision frequency, electrochemical biosensor
- MeSH terms
- Animals, Antibodies, Viral, Cytomegalovirus, Humans, Microelectrodes, NIH 3T3 Cells, Mice, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.