Contractility of single cardiomyocytes differentiated from pluripotent stem cells depends on physiological shape and substrate stiffness
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Significance: Human cardiomyocytes differentiated from pluripotent stem cells (hPSC-CMs) have potential as in vitro models of cardiac health and disease but differ from mature cardiomyocytes. In single live engineered hPSC-CMs with physiological shapes, we assayed the mechanical output and activity of sarcomeres and myofibrils in a nondestructive, noninvasive manner. Substrates with physiological stiffness improved contractile activity of patterned hPSC-CMs, as well as calcium flow, mitochondrial organization, electrophysiology, and transverse-tubule formation. The mechanical output and activity of sarcomeres and myofibrils varied as a function of mechanical cues and disrupted cell tension. This study establishes a high-throughput platform for modeling single-cell cardiac contractile activity and yields insight into environmental factors that drive maturation and sarcomere function in hPSC-CMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell locomotion and focal adhesions are regulated by substrate flexibility
Pelham, R. J., & Wang, Y.-L. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13661 · Cited by 3,027
Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325
Lifeact: a versatile marker to visualize F-actin
Riedl, J., Crevenna, A. H., Kessenbrock, K., Yu, J. H., Neukirchen, D., Bista, M., Bradke, F., Jenne, D., Holak, T. A., Werb, Z., et al. (2008) · Nature Methods · doi:10.1038/nmeth.1220 · Cited by 2,189
Matrigel: A complex protein mixture required for optimal growth of cell culture
Hughes, C. S., Postovit, L. M., & Lajoie, G. A. (2010) · PROTEOMICS · doi:10.1002/pmic.200900758 · Cited by 1,534 · cited 1×
“Matrigel is an extracellular matrix mixture (14), and CMs assume the shape of micropatterns of extracellular proteins printed on surfaces (11, 15, 16).”
BackgroundEngineering Adolescence: Maturation of Human Pluripotent Stem Cell–Derived Cardiomyocytes
Yang, X., Pabon, L., & Murry, C. E. (2014) · Circulation Research · doi:10.1161/circresaha.114.300558 · Cited by 939 · cited 6×
“High myofibril alignment along the major axis is a hallmark of CM maturity (6), and the myofibril alignment index (AI) also increased with the aspect ratio (Fig.”
BackgroundInfluentialCaveolae as plasma membrane sensors, protectors and organizers
Parton, R. G., & del Pozo, M. A. (2013) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3512 · Cited by 924
Actin stress fibers – assembly, dynamics and biological roles
Tojkander, S., Gateva, G., & Lappalainen, P. (2012) · Journal of Cell Science · doi:10.1242/jcs.098087 · Cited by 900 · cited 2×
“Nonmuscle actin stress fibers have several homologies with their myofibril isoforms in contractility, organization, and composition (49, 52, 53).”
BackgroundEngler, A. J., Carag-Krieger, C., Johnson, C. P., Raab, M., Tang, H.-Y., Speicher, D. W., Sanger, J. W., Sanger, J. M., & Discher, D. E. (2008) · Journal of Cell Science · doi:10.1242/jcs.029678 · Cited by 865
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Granzier, H. L., & Irving, T. C. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80278-x · Cited by 640
Cited by
Cardiomyocyte maturation: advances in knowledge and implications for regenerative medicine
Karbassi, E., Fenix, A., Marchiano, S., Muraoka, N., Nakamura, K., Yang, X., & Murry, C. E. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0331-x · Cited by 755
Bioengineering strategies to accelerate stem cell therapeutics
Madl, C. M., Heilshorn, S. C., & Blau, H. M. (2018) · Nature · doi:10.1038/s41586-018-0089-z · Cited by 425
Sala, L., van Meer, B. J., Tertoolen, L. G. J., Bakkers, J., Bellin, M., Davis, R. P., Denning, C., Dieben, M. A. E., Eschenhagen, T., Giacomelli, E., et al. (2018) · Circulation Research · doi:10.1161/circresaha.117.312067 · Cited by 416
“Please refer to the Installation section for more information on how to download and install ImageJ.”
InfluentialMa, X., Liu, J., Zhu, W., Tang, M., Lawrence, N., Yu, C., Gou, M., & Chen, S. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.011 · Cited by 401
Parikh, S. S., Blackwell, D. J., Gomez-Hurtado, N., Frisk, M., Wang, L., Kim, K., Dahl, C. P., Fiane, A., Tønnessen, T., Kryshtal, D. O., et al. (2017) · Circulation Research · doi:10.1161/circresaha.117.311920 · Cited by 376
Tuning the Range of Polyacrylamide Gel Stiffness for Mechanobiology Applications
Denisin, A. K., & Pruitt, B. L. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b09344 · Cited by 313
Self-citationDenning, C., Borgdorff, V., Crutchley, J., Firth, K. S. A., George, V., Kalra, S., Kondrashov, A., Hoang, M. D., Mosqueira, D., Patel, A., et al. (2016) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2015.10.014 · Cited by 293
Mechanosensing by the Lamina Protects against Nuclear Rupture, DNA Damage, and Cell-Cycle Arrest
Cho, S., Vashisth, M., Abbas, A., Majkut, S., Vogel, K., Xia, Y., Ivanovska, I. L., Irianto, J., Tewari, M., Zhu, K., et al. (2019) · Developmental Cell · doi:10.1016/j.devcel.2019.04.020 · Cited by 297
Multi-lineage human iPSC-derived platforms for disease modeling and drug discovery
Sharma, A., Sances, S., Workman, M. J., & Svendsen, C. N. (2020) · Cell Stem Cell · doi:10.1016/j.stem.2020.02.011 · Cited by 296
“Scaffolded platforms can also incorporate micropatterning to force cells such as hiPSC-derived cardiomyocytes to adopt more physiologically relevant shapes in hopes of enhancing cell maturity (Ribeiro et al., 2015; Serpooshan et al., 2017).”
BackgroundDisease Model of GATA4 Mutation Reveals Transcription Factor Cooperativity in Human Cardiogenesis
Ang, Y.-S., Rivas, R. N., Ribeiro, A. J. S., Srivas, R., Rivera, J., Stone, N. R., Pratt, K., Mohamed, T. M. A., Fu, J.-D., Spencer, C. I., et al. (2016) · Cell · doi:10.1016/j.cell.2016.11.033 · Cited by 294
“Micro-patterning and Image Analyses CM contractile function was analyzed after seeding cells on polyacrylamide hydrogel devices containing matrigel micropatterns that were fabricated as previously detailed (Ribeiro et al., 2015).”
MethodInfluentialSelf-citationStem Cell Differentiation is Regulated by Extracellular Matrix Mechanics
Smith, L. R., Cho, S., & Discher, D. E. (2018) · Physiology · doi:10.1152/physiol.00026.2017 · Cited by 280
Herron, T. J., Rocha, A. M. D., Campbell, K. F., Ponce-Balbuena, D., Willis, B. C., Guerrero-Serna, G., Liu, Q., Klos, M., Musa, H., Zarzoso, M., et al. (2016) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.003638 · Cited by 257
“Mounting evidence has made it apparent that combining matrigel with softer synthetic biomaterials is a way to produce more mature hPSC and ESC-derived human cardiomyocytes that will be more useful for disease modeling, drug testing, and cardiac regeneration applications.(42,43) This study is unique in that we have stu…”
BackgroundMechanical control of cardiac myofibroblasts
van Putten, S., Shafieyan, Y., & Hinz, B. (2016) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2015.11.025 · Cited by 234
“diomyocyte differentiation from progenitors, their maturation, and contractile behavior [100,102–105].”
BackgroundMusunuru, K., Sheikh, F., Gupta, R. M., Houser, S. R., Maher, K. O., Milan, D. J., Terzic, A., & Wu, J. C. (2018) · Circulation: Genomic and Precision Medicine · doi:10.1161/hcg.0000000000000043 · Cited by 229
Paik, D. T., Chandy, M., & Wu, J. C. (2020) · Pharmacological Reviews · doi:10.1124/pr.116.013003 · Cited by 216
“…generated using standard protocols display round or polygonal cellular morphology with sarcomeric disorganization, whereasmature adult CMs are rod-shaped and elongated with an aspect ratio of 5:1 to 9:1 and an anisotropic distribution of myofilaments (Gerdes et al., 1992; Ribeiro et al., 2015a).”
BackgroundChallenges and opportunities for the next generation of cardiovascular tissue engineering
Cho, S., Discher, D. E., Leong, K. W., Vunjak-Novakovic, G., & Wu, J. C. (2022) · Nature Methods · doi:10.1038/s41592-022-01591-3 · Cited by 176
Chopra, A., Kutys, M. L., Zhang, K., Polacheck, W. J., Sheng, C. C., Luu, R. J., Eyckmans, J., Hinson, J. T., Seidman, J. G., Seidman, C. E., et al. (2018) · Developmental Cell · doi:10.1016/j.devcel.2017.12.012 · Cited by 169
Complex Tissue and Disease Modeling using hiPSCs
Passier, R., Orlova, V., & Mummery, C. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2016.02.011 · Cited by 142
Cardiac Tissues From Stem Cells: New Routes to Maturation and Cardiac Regeneration
Campostrini, G., Windt, L. M., van Meer, B. J., Bellin, M., & Mummery, C. L. (2021) · Circulation Research · doi:10.1161/circresaha.121.318183 · Cited by 96
Bioengineering approaches to treat the failing heart: from cell biology to 3D printing
Yadid, M., Oved, H., Silberman, E., & Dvir, T. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00603-7 · Cited by 83
Dunn, K. K., & Palecek, S. P. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2018.00110 · Cited by 41
Fang, Y., Sun, W., Zhang, T., & Xiong, Z. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2021.121298 · Cited by 40
Engineering the cardiac tissue microenvironment
Ronan, G., Bahcecioglu, G., Aliyev, N., & Zorlutuna, P. (2024) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0ea7 · Cited by 4
Metadata
- Authors
- Ribeiro, A. J. S., Ang, Y.-S., Fu, J.-D., Rivas, R. N., Mohamed, T. M. A., Higgs, G. C., Srivastava, D., & Pruitt, B. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2015-09-28
- Volume
- 112
- Issue
- 41
- Pages
- 12705-12710
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2200325631
- Cited by
- 479
- References
- 65
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.