Mechanogenetics for the remote and noninvasive control of cancer immunotherapy
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Significance: There is a lack of a general method to noninvasively and remotely manipulate cells with high spatiotemporal precisions. We developed an ultrasound-based mechanogenetics system to achieve this goal. Cells were engineered with the mechanosensor Piezo1 and genetic transducing modules to perceive the mechanical perturbation generated by the ultrasound wave and transduce it into genetic activities. Mechanosensitive and ultrasound-controllable T cells were further engineered to target and eradicate tumor cells with inducible chimeric antigen receptors. This mechanogenetics approach can be extended to remotely control, in principle, any gene activity in live cells for the reprogramming of cellular functions. This method should also provide a general approach to remotely control molecular functions for biological studies and clinical applications, particularly cell-based cancer immunotherapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chimeric Antigen Receptor–Modified T Cells for Acute Lymphoid Leukemia
Grupp, S. A., Kalos, M., Barrett, D., Aplenc, R., Porter, D. L., Rheingold, S. R., Teachey, D. T., Chew, A., Hauck, B., Wright, J. F., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1215134 · Cited by 3,509 · cited 2×
“W the use of central memory T cells capable of suppressing cancer relapse for several years (1), chimeric antigen receptor (CAR) T-cell immunotherapy is transforming cancer therapy (2).”
BackgroundMethodPiezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 1×
“1A), which has been identified as a component of mechanically activated (MA) cation channels (16) and is inherently mechanosensitive (17).”
BackgroundMorgan, R. A., Yang, J. C., Kitano, M., Dudley, M. E., Laurencot, C. M., & Rosenberg, S. A. (2010) · Molecular Therapy · doi:10.1038/mt.2010.24 · Cited by 2,533
Highly efficient Cas9-mediated transcriptional programming
Chavez, A., Scheiman, J., Vora, S., Pruitt, B. W., Tuttle, M., P R Iyer, E., Lin, S., Kiani, S., Guzman, C. D., Wiegand, D. J., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3312 · Cited by 1,622
Engineered T cells: the promise and challenges of cancer immunotherapy
Fesnak, A. D., June, C. H., & Levine, B. L. (2016) · Nature Reviews Cancer · doi:10.1038/nrc.2016.97 · Cited by 1,074
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Zhao, Z., Condomines, M., van der Stegen, S. J. C., Perna, F., Kloss, C. C., Gunset, G., Plotkin, J., & Sadelain, M. (2015) · Cancer Cell · doi:10.1016/j.ccell.2015.09.004 · Cited by 843
Self-citationVisualizing the mechanical activation of Src
Wang, Y., Botvinick, E. L., Zhao, Y., Berns, M. W., Usami, S., Tsien, R. Y., & Chien, S. (2005) · Nature · doi:10.1038/nature03469 · Cited by 680
Self-citation
Cited by
Delivery technologies for cancer immunotherapy
Riley, R. S., June, C. H., Langer, R., & Mitchell, M. J. (2019) · Nature Reviews Drug Discovery · doi:10.1038/s41573-018-0006-z · Cited by 2,607
Ionizable Lipid Nanoparticle-Mediated mRNA Delivery for Human CAR T Cell Engineering
Billingsley, M. M., Singh, N., Ravikumar, P., Zhang, R., June, C. H., & Mitchell, M. J. (2020) · Nano Letters · doi:10.1021/acs.nanolett.9b04246 · Cited by 636
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Overcoming on-target, off-tumour toxicity of CAR T cell therapy for solid tumours
Flugel, C. L., Majzner, R. G., Krenciute, G., Dotti, G., Riddell, S. R., Wagner, D. L., & Abou-el-Enein, M. (2023) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00704-3 · Cited by 554
Engineering living therapeutics with synthetic biology
Cubillos-Ruiz, A., Guo, T., Sokolovska, A., Miller, P. F., Collins, J. J., Lu, T. K., & Lora, J. M. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-021-00285-3 · Cited by 356
Molecular and nanoengineering approaches towards activatable cancer immunotherapy
Zhang, C., & Pu, K. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00773c · Cited by 302
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Cancer-cell stiffening via cholesterol depletion enhances adoptive T-cell immunotherapy
Lei, K., Kurum, A., Kaynak, M., Bonati, L., Han, Y., Cencen, V., Gao, M., Xie, Y.-Q., Guo, Y., Hannebelle, M. T. M., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00826-6 · Cited by 276
Self-citationQiu, Z., Guo, J., Kala, S., Zhu, J., Xian, Q., Qiu, W., Li, G., Zhu, T., Meng, L., Zhang, R., et al. (2019) · iScience · doi:10.1016/j.isci.2019.10.037 · Cited by 266
Ultrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
“Since then, several other established or putative MSCs, including MscL (Ye et al., 2018), Piezo1 (Pan et al., 2018; Prieto et al., 2018), MEC-4, DEG/ENaC/ASIC (Kubanek et al., 2018), Prestin (Huang et al., 2020), TREK-1/2, TRAAK (Kubanek et al., 2016), TRPP1/2 and TRPC1 (Yoo et al., 2020) have been reported to sensiti…”
Ultrasound activates mechanosensitive TRAAK K + channels through the lipid membrane
Sorum, B., Rietmeijer, R. A., Gopakumar, K., Adesnik, H., & Brohawn, S. G. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006980118 · Cited by 187
“Similarly, the Mus musculus mechanosensitive channel Piezo1 is activated by ultrasound stimulation in the presence of microbubbles or in their absence using higher-frequency and -power stimulation (22, 42).”
Applications of focused ultrasound-mediated blood-brain barrier opening
Gorick, C. M., Breza, V. R., Nowak, K. M., Cheng, V. W. T., Fisher, D. G., Debski, A. C., Hoch, M. R., Demir, Z. E. F., Tran, N. M., Schwartz, M. R., et al. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114583 · Cited by 144
A Plug-and-Latch Mechanism for Gating the Mechanosensitive Piezo Channel
Geng, J., Liu, W., Zhou, H., Zhang, T., Wang, L., Zhang, M., Li, Y., Shen, B., Li, X., & Xiao, B. (2020) · Neuron · doi:10.1016/j.neuron.2020.02.010 · Cited by 113
Mittelheisser, V., Gensbittel, V., Bonati, L., Li, W., Tang, L., & Goetz, J. G. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01535-8 · Cited by 109
“A sonic stimulus of integrin-bound microbubbles was used to induce calcium influx 210 through PIEZO1 channels in T cells in vitro.”
Engineering approaches for studying immune-tumor cell interactions and immunotherapy
Shelton, S. E., Nguyen, H. T., Barbie, D. A., & Kamm, R. D. (2021) · iScience · doi:10.1016/j.isci.2020.101985 · Cited by 93
Cellular mechanoactivation of antigen-presenting cells and T cells for cancer immunotherapy
Ghazanfari, D., Ren, L., Cantú, M. S., & King, M. R. (2025) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2025.100619 · Cited by 3
Metadata
- Authors
- Pan, Y., Yoon, S., Sun, J., Huang, Z., Lee, C., Allen, M., Wu, Y., Chang, Y.-J., Sadelain, M., Shung, K. K., Chien, S., & Wang, Y.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-01-17
- Volume
- 115
- Issue
- 5
- Pages
- 992-997
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2783252349
- Cited by
- 267
- References
- 31
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.