The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cellular and nerve regeneration within a biosynthetic extracellular matrix for corneal transplantation
Open accessAbstract
Our objective was to determine whether key properties of extracellular matrix (ECM) macromolecules can be replicated within tissue-engineered biosynthetic matrices to influence cellular properties and behavior. To achieve this, hydrated collagen and N -isopropylacrylamide copolymer-based ECMs were fabricated and tested on a corneal model. The structural and immunological simplicity of the cornea and importance of its extensive innervation for optimal functioning makes it an ideal test model. In addition, corneal failure is a clinically significant problem. Matrices were therefore designed to have the optical clarity and the proper dimensions, curvature, and biomechanical properties for use as corneal tissue replacements in transplantation. In vitro studies demonstrated that grafting of the laminin adhesion pentapeptide motif, YIGSR, to the hydrogels promoted epithelial stratification and neurite in-growth. Implants into pigs' corneas demonstrated successful in vivo regeneration of host corneal epithelium, stroma, and nerves. In particular, functional nerves were observed to rapidly regenerate in implants. By comparison, nerve regeneration in allograft controls was too slow to be observed during the experimental period, consistent with the behavior of human cornea transplants. Other corneal substitutes have been produced and tested, but here we report an implantable matrix that performs as a physiologically functional tissue substitute and not simply as a prosthetic device. These biosynthetic ECM replacements should have applicability to many areas of tissue engineering and regenerative medicine, especially where nerve function is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human cornea and sclera studied by atomic force microscopy
Meller, D., Meller, K., & Peters, K. (1997) · Cell and Tissue Research · doi:10.1007/s004410050798 · Cited by 88
Cited by
Advantages of RGD peptides for directing cell association with biomaterials
Bellis, S. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.029 · Cited by 745
Fagerholm, P., Lagali, N. S., Merrett, K., Jackson, W. B., Munger, R., Liu, Y., Polarek, J. W., Söderqvist, M., & Griffith, M. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001022 · Cited by 420
Self-citation3D bioprinting of a corneal stroma equivalent
Isaacson, A., Swioklo, S., & Connon, C. J. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.05.010 · Cited by 419
Duan, X., & Sheardown, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.022 · Cited by 306
Self-citationFujimoto, K. L., Ma, Z., Nelson, D. M., Hashizume, R., Guan, J., Tobita, K., & Wagner, W. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.055 · Cited by 269
Metadata
- Authors
- Li, F., Carlsson, D., Lohmann, C., Suuronen, E., Vascotto, S., Kobuch, K., Sheardown, H., Munger, R., Nakamura, M., & Griffith, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-12-05
- Volume
- 100
- Issue
- 26
- Pages
- 15346-15351
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2089858022
- Cited by
- 244
- References
- 1
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cellular and nerve regeneration within a biosynthetic extracellular matrix for corneal transplantation. https://app.cochat.ai/papers/10.1073/pnas.2536767100
- The paper
- Li, F., Carlsson, D., Lohmann, C., Suuronen, E., Vascotto, S., Kobuch, K., Sheardown, H., Munger, R., Nakamura, M., & Griffith, M. (2003). Cellular and nerve regeneration within a biosynthetic extracellular matrix for corneal transplantation. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2536767100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.