The DOI matches its Crossref record.
Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier Transforms
Open accessAbstract
A new technique is proposed for the mathematical process of reconstruction of a three-dimensional object from its transmission shadowgraphs; it uses convolutions with functions defined in the real space of the object, without using Fourier transforms. The object is rotated about an axis at right angles to the direction of a parallel beam of radiation, and sections of it normal to the axis are reconstructed from data obtained by scanning the corresponding linear strips in the shadowgraphs at different angular settings. Since the formulae in the convolution method involve only summations over one variable at a time, while a two-dimensional reconstruction with the Fourier transform technique requires double summations, the convolution method is much faster (typically by a factor of 30); the relative increase in speed is larger where greater resolution is required. Tests of the convolution method with computer-simulated shadowgraphs show that it is also more accurate than the Fourier transform method. It has good potentialities for application in electron microscopy and x-radiography. A new method of reconstructing helical structures by this technique is also suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ketcham, R. A., & Carlson, W. D. (2001) · Computers & Geosciences · doi:10.1016/s0098-3004(00)00116-3 · Cited by 1,518
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Metadata
- Authors
- Ramachandran, G. N., & Lakshminarayanan, A. V.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1971-09
- Volume
- 68
- Issue
- 9
- Pages
- 2236-2240
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2020510568
- Cited by
- 984
- References
- 0
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier Transforms. https://app.cochat.ai/papers/10.1073/pnas.68.9.2236
- The paper
- Ramachandran, G. N., & Lakshminarayanan, A. V. (1971). Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier Transforms. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.68.9.2236
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.