The DOI matches its Crossref record.
Generation of protein-reactive antibodies by short peptides is an event of high frequency: implications for the structural basis of immune recognition.
Open accessAbstract
Recent studies have shown that chemically synthesized small peptides can induce antibodies that often react with intact proteins regardless of their position in the folded molecule. These findings are difficult to explain in view of the experimental and theoretical data which suggest that in the absence of forces provided by the folded protein, small peptides in aqueous solution do not readily adopt stable structures. In order to rationalize the two findings, there has been general acceptance of a stochastic model which suggests that the multiple conformers of a peptide in solution induce sets of antibodies with a small percentage reactive with conformations shared by the folded protein. This stochastic model has become less tenable as the success rate for the generation of protein-reactive anti-peptide antibodies has grown. To test the stochastic model, we have used monoclonal anti-peptide antibodies as a way of estimating the frequency with which small peptides induce antibodies that react with folded proteins. We have made monoclonal antibodies to six chemically synthesized peptides from three proteins. The frequency with which the peptides induce protein-reactive antibodies is at least 4 orders of magnitude greater than expected from previous experimental work and vastly different from what would be predicted by calculating the possible number of peptide conformers in solution. These findings make the stochastic model less likely and lead to consideration of other models. Aside from their practical significance for generation of highly specific reagents, these findings may have important implications for the protein folding problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Houghten, R. A. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.15.5131 · Cited by 1,643
Self-citationReverse Transcriptase Encoded by a Human Transposable Element
Mathias, S. L., Scott, A. F., Kazazian, H. H., Boeke, J. D., & Gabriel, A. (1991) · Science · doi:10.1126/science.1722352 · Cited by 773
A nuclear localization domain in the hnRNP A1 protein.
Siomi, H., & Dreyfuss, G. (1995) · The Journal of cell biology · doi:10.1083/jcb.129.3.551 · Cited by 503
Eide, F. F., Vining, E. R., Eide, B. L., Zang, K., Wang, X.-Y., & Reichardt, L. F. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-10-03123.1996 · Cited by 474
BIN1 is a novel MYC–interacting protein with features of a tumour suppressor
Sakamuro, D., Elliott, K. J., Wechsler-Reya, R., & Prendergast, G. C. (1996) · Nature Genetics · doi:10.1038/ng0996-69 · Cited by 387
Metadata
- Authors
- Niman, H. L., Houghten, R. A., Walker, L. E., Reisfeld, R. A., Wilson, I. A., Hogle, J. M., & Lerner, R. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1983-08
- Volume
- 80
- Issue
- 16
- Pages
- 4949-4953
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2021595960
- Cited by
- 377
- References
- 0
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generation of protein-reactive antibodies by short peptides is an event of high frequency: implications for the structural basis of immune recognition. https://app.cochat.ai/papers/10.1073/pnas.80.16.4949
- The paper
- Niman, H. L., Houghten, R. A., Walker, L. E., Reisfeld, R. A., Wilson, I. A., Hogle, J. M., & Lerner, R. A. (1983). Generation of protein-reactive antibodies by short peptides is an event of high frequency: implications for the structural basis of immune recognition. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.80.16.4949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.