Fluorescence quantum yield of visual pigments: evidence for subpicosecond isomerization rates.
Open accessThe DOI matches its Crossref record.
Abstract
The fluorescence quantum yields (phi f) for bovine and squid rhodopsins are determined. Both pigments yield similar results, with an average value for phi f of 1.2 (+/- 0.5) X 10(-5). Since the estimated radiative lifetime of rhodopsin is 5 nsec, the rate constant of the process that competes with fluorescence must be on the order of 0.1 psec. Given the large quantum yield for isomerization of rhodopsin's retinal chromophore, this process is likely to correspond to the motion along retinal's C11-C12 torsional coordinate that leads to cis-trans isomerization. An empirical excited-state potential energy curve along this coordinate is derived. It is shown that subpicosecond torsional motion to highly twisted nonfluorescing regions of the potential is possible and, in fact, likely. Our results require the existence of a barrier-less excited-state potential energy curve and suggest that cis-trans isomerization occurs in less than 1 psec.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Rettig, W. (1986) · Angewandte Chemie International Edition in English · doi:10.1002/anie.198609711 · Cited by 1,324
Microbial and Animal Rhodopsins: Structures, Functions, and Molecular Mechanisms
Ernst, O. P., Lodowski, D. T., Elstner, M., Hegemann, P., Brown, L. S., & Kandori, H. (2014) · Chemical Reviews · doi:10.1021/cr4003769 · Cited by 1,153
The First Step in Vision: Femtosecond Isomerization of Rhodopsin
Schoenlein, R. W., Peteanu, L. A., Mathies, R. A., & Shank, C. V. (1991) · Science · doi:10.1126/science.1925597 · Cited by 892
Direct Observation of the Femtosecond Excited-State cis - trans Isomerization in Bacteriorhodopsin
Mathies, R. A., Brito Cruz, C. H., Pollard, W. T., & Shank, C. V. (1988) · Science · doi:10.1126/science.3363359 · Cited by 558
Metadata
- Authors
- Doukas, A. G., Junnarkar, M. R., Alfano, R. R., Callender, R. H., Kakitani, T., & Honig, B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1984-08
- Volume
- 81
- Issue
- 15
- Pages
- 4790-4794
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1964037600
- Cited by
- 85
- References
- 0
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence quantum yield of visual pigments: evidence for subpicosecond isomerization rates. https://app.cochat.ai/papers/10.1073/pnas.81.15.4790
- The paper
- Doukas, A. G., Junnarkar, M. R., Alfano, R. R., Callender, R. H., Kakitani, T., & Honig, B. (1984). Fluorescence quantum yield of visual pigments: evidence for subpicosecond isomerization rates. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.81.15.4790
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.