Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 311

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A large region (approximately equal to 95 kDa) of human factor VIII is dispensable for in vitro procoagulant activity.

Open access
Toole, J J, Pittman, D D, Orr, E C, Murtha, P, Wasley, L C, Kaufman, R J·1986·Proceedings of the National Academy of Sciences

Abstract

Factor VIII (antihemophilic factor) is a high molecular weight plasma glycoprotein that participates in the blood clotting cascade. The recent cloning and sequence analysis of the cDNA encoding human factor VIII revealed an obvious domain structure for the protein, which can be represented as A1-A2-B-A3-C1-C2. We now report the DNA sequence analysis of porcine exons encoding the entire B domain and part of the A2 and A3 domains. We found an unusually high degree of porcine-human amino acid sequence divergence in the B region compared with the limited sequence available for other regions of the porcine factor VIII molecule. In addition to sequence divergence, there are numerous gaps in the porcine B domain totalling over 200 amino acids. Recombinant DNA techniques were used to effect the removal of large segments of DNA encoding the B domain from the full-length human factor VIII cDNA. These constructs directed the synthesis of biologically active factor VIII when introduced into mammalian cells despite the deletion of up to 38% of the factor VIII molecule.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.83.16.5939

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 311

Metadata

Authors
Toole, J. J., Pittman, D. D., Orr, E. C., Murtha, P., Wasley, L. C., & Kaufman, R. J.
Venue
Proceedings of the National Academy of Sciences
Published
1986-08
Volume
83
Issue
16
Pages
5939-5942
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2073305192
Cited by
311
References
13
FWCI
6.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A large region (approximately equal to 95 kDa) of human factor VIII is dispensable for in vitro procoagulant activity. https://app.cochat.ai/papers/10.1073/pnas.83.16.5939
The paper
Toole, J. J., Pittman, D. D., Orr, E. C., Murtha, P., Wasley, L. C., & Kaufman, R. J. (1986). A large region (approximately equal to 95 kDa) of human factor VIII is dispensable for in vitro procoagulant activity. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.83.16.5939

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.