The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nucleotide sequence of the gene coding for human factor VII, a vitamin K-dependent protein participating in blood coagulation.
Open accessAbstract
Activated factor VII (factor VIIa) is a vitamin K-dependent plasma serine protease that participates in a cascade of reactions leading to the coagulation of blood. Two overlapping genomic clones containing sequences encoding human factor VII were isolated and characterized. The complete sequence of the gene was determined and found to span about 12.8 kilobases. The mRNA for factor VII as demonstrated by cDNA cloning is polyadenylylated at multiple sites but contains only one AAUAAA poly(A) signal sequence. The mRNA can undergo alternative splicing, forming one transcript containing eight segments as exons and another with an additional exon that encodes a larger prepro leader sequence. The latter transcript has no known counterpart in the other vitamin K-dependent proteins. The positions of the introns with respect to the amino acid sequence encoded by the eight essential exons of factor VII are the same as those present in factor IX, factor X, protein C, and the first three exons of prothrombin. These exons code for domains generally conserved among members of this gene family. The comparable introns in these genes, however, are dissimilar with respect to size and sequence, with the exception of intron C in factor VII and protein C. The gene for factor VII also contains five regions made up of tandem repeats of oligonucleotide monomer elements. More than a quarter of the intron sequences and more than a third of the 3' untranslated portion of the mRNA transcript consist of these minisatellite tandem repeats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gilbert, W. (1978) · Nature · doi:10.1038/271501a0 · Cited by 2,300
Cited by
The molecular basis of blood coagulation
Furie, B., & Furie, B. C. (1988) · Cell · doi:10.1016/0092-8674(88)90567-3 · Cited by 1,247
Biomaterials and Advanced Technologies for Hemostatic Management of Bleeding
Hickman, D. A., Pawlowski, C. L., Sekhon, U. D. S., Marks, J., & Gupta, A. S. (2018) · Advanced Materials · doi:10.1002/adma.201700859 · Cited by 583
Long-Range Correlation and Partial 1/ f α Spectrum in a Noncoding DNA Sequence
Li, W., & Kaneko, K. (1992) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/17/7/014 · Cited by 414
Nucleotide sequence of the gene for human prothrombin
Degen, S. J. F., & Davie, E. W. (1987) · Biochemistry · doi:10.1021/bi00393a033 · Cited by 258
Freeman, M. S., Mansfield, M. W., Barrett, J. H., & Grant, P. J. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/hq0302.104906 · Cited by 82
Metadata
- Authors
- O'Hara, P. J., Grant, F. J., Haldeman, B. A., Gray, C. L., Insley, M. Y., Hagen, F. S., & Murray, M. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1987-08
- Volume
- 84
- Issue
- 15
- Pages
- 5158-5162
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2149221304
- Cited by
- 296
- References
- 1
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nucleotide sequence of the gene coding for human factor VII, a vitamin K-dependent protein participating in blood coagulation. https://app.cochat.ai/papers/10.1073/pnas.84.15.5158
- The paper
- O'Hara, P. J., Grant, F. J., Haldeman, B. A., Gray, C. L., Insley, M. Y., Hagen, F. S., & Murray, M. J. (1987). Nucleotide sequence of the gene coding for human factor VII, a vitamin K-dependent protein participating in blood coagulation. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.84.15.5158
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.