CoChat
Cited by 1,194

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Direct measurement of free radical generation following reperfusion of ischemic myocardium.

Open access
Zweier, J L, Flaherty, J T, Weisfeldt, M L · 1987 · Proceedings of the National Academy of Sciences

Abstract

Electron paramagnetic resonance spectroscopy was used to directly measure free radical generation in perfused rabbit hearts. Hearts were freeze-clamped at 77 degrees K during control perfusion, after 10 min of normothermic global ischemia (no coronary flow), or following post-ischemic reperfusion with oxygenated perfusate. The spectra of these hearts exhibited three different signals with different power saturation and temperature stability: signal A was isotropic with g = 2.004; signal B was anisotropic with axial symmetry with g parallel = 2.033 and g perpendicular = 2.005; signal C was an isotropic triplet with g = 2.000 and hyperfine splitting an = 24 G (1 G = 0.1 mT). The g values, linewidth, power saturation, and temperature stability of signal A are identical to those of a carbon-centered semiquinone, whereas those of signal B are similar to alkyl peroxyl or superoxide oxygen-centered free radicals; signal C is most likely a nitrogen-centered free radical. In the control heart samples signal A predominated, whereas in ischemic hearts signal A decreased in intensity, and signals B and C became more intense; with reperfusion all three signals markedly increased. Free radical concentrations derived from the intensities of the B and C signals peaked 10 sec after initiation of reflow. At this time the oxygen-centered free radical concentration derived from the intensity of signal B was increased over six times the concentration measured in control hearts and over two times the concentration measured in ischemic hearts. Hypoxic reperfusion did not increase any of the free radical signals over the levels observed during ischemia. These experiments directly demonstrate that reactive oxygen-centered free radicals are generated in hearts during ischemia and that a burst of oxygen radical generation occurs within moments of reperfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.84.5.1404

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1,194

Metadata

Authors
Zweier, J. L., Flaherty, J. T., & Weisfeldt, M. L.
Venue
Proceedings of the National Academy of Sciences
Published
1987-03
Volume
84
Issue
5
Pages
1404-1407
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2037121432
Cited by
1,194
References
11
FWCI
39.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.