The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Simultaneous electrical and optical measurements show that membrane fusion precedes secretory granule swelling during exocytosis of beige mouse mast cells.
Open accessAbstract
Mast cells show dramatic morphological changes when undergoing exocytosis. We have investigated whether the first of those morphological changes, swelling of the secretory granule, precedes--and therefore possibly initiates--secretion or whether it occurs after fusion of the granule and plasma membranes. We used cell membrane capacitance to detect the moment when granule and plasma membrane become continuous. We measured large capacitance increases, often preceded by transients in capacitance. The rise-times of the capacitance increases were half-maximal at 2-59 msec. We observed cells with high-resolution video microscopy while these measurements were done. The capacitance increase always preceded the granular swelling that leads to exocytosis. To rule out the possibility that fusion was induced by a mechanical stress imparted by the internal pressure of a taut granule, we performed control experiments using cells in which vesicles were shrunken with hyperosmotic solutions. With these flaccid granules, again, the capacitance rise always preceded the swelling of the granules. We conclude that swelling cannot be the driving force for membrane fusion in this system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Cited by
Südhof, T. C. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.26.041002.131412 · Cited by 2,547
Creutz, C. E. (1992) · Science · doi:10.1126/science.1439804 · Cited by 548
Lighting the fuse at fertilization
Whitaker, M., & Swann, K. (1993) · Development · doi:10.1242/dev.117.1.1 · Cited by 323
Selective nucleotide-release from dense-core granules in insulin-secreting cells
Obermüller, S., Lindqvist, A., Karanauskaite, J., Galvanovskis, J., Rorsman, P., & Barg, S. (2005) · Journal of Cell Science · doi:10.1242/jcs.02549 · Cited by 138
Metadata
- Authors
- Zimmerberg, J., Curran, M., Cohen, F. S., & Brodwick, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1987-03
- Volume
- 84
- Issue
- 6
- Pages
- 1585-1589
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2000364427
- Cited by
- 283
- References
- 1
- FWCI
- 10.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous electrical and optical measurements show that membrane fusion precedes secretory granule swelling during exocytosis of beige mouse mast cells. https://app.cochat.ai/papers/10.1073/pnas.84.6.1585
- The paper
- Zimmerberg, J., Curran, M., Cohen, F. S., & Brodwick, M. (1987). Simultaneous electrical and optical measurements show that membrane fusion precedes secretory granule swelling during exocytosis of beige mouse mast cells. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.84.6.1585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.