Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 165

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Isolation of aminoacyl-tRNA and its labeling with stable-isotope tracers: Use in studies of human tissue protein synthesis.

Open access
Watt, P W, Lindsay, Y, Scrimgeour, C M, Chien, P A, Gibson, J N, Taylor, D J, Rennie, M J · 1991 · Proceedings of the National Academy of Sciences

Abstract

We isolated aminoacyl-tRNA (60-70% yield) from human and rat tissues and measured, by GC/MS, its labeling in vivo by [15N]- and [13C]leucine. Tracer dilution artifacts seemed unlikely since, after infusion of L-[1-13C,15N]leucine into rats, (i) muscle leucyl-tRNA labeling exceeded tissue free leucine labeling, (ii) values were largely unaffected by storing over 5 min at 22 degrees C, and (iii) L-[2,4,5-methyl-13C]leucine was not incorporated into leucyl-tRNA during homogenization. Leucyl-tRNA labeling in liver and muscle suggested charging from extra- and intracellular pools: e.g., after infusing L-[1-13C,15N]leucine, rat muscle tissue free leucine 13C labeling (8.97 +/- 0.30 atom % excess) exceeded that by 15N (3.37 +/- 0.33 atom % excess), and both were significantly lower (P less than 0.02) than venous plasma (13C, 12.1 +/- 1.8; 15N, 5.54 +/- 0.6 atom % excess) indicating tracer dilution by transamination and by proteolysis; however, leucyl-tRNA labeling by either isotope (13C, 10.26 +/- 0.50; 15N, 4.72 +/- 0.72 atom % excess) was significantly above mixed tissue free leucine (P less than 0.05). Labeling of leucyl-tRNA in human erector spinae muscle (obtained after preoperative L-[1-13C]leucine infusion) was, at 4.98 +/- 0.43 atom % excess, lower (27%) than venous plasma leucine (P less than 0.05) and intermediate between muscle free leucine (9% lower; P less than 0.01) and venous alpha-ketoisocaproate (11% higher; P less than 0.02). Human placental leucyl-tRNA labeling (after predelivery tracer infusion) was 37% lower (P less than 0.05) than maternal uterine vein labeling but not significantly different from placental free leucine or umbilical arterial leucine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.88.13.5892

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 165

Metadata

Authors
Watt, P. W., Lindsay, Y., Scrimgeour, C. M., Chien, P. A., Gibson, J. N., Taylor, D. J., & Rennie, M. J.
Venue
Proceedings of the National Academy of Sciences
Published
1991-07
Volume
88
Issue
13
Pages
5892-5896
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2053721786
Cited by
165
References
2
FWCI
2.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isolation of aminoacyl-tRNA and its labeling with stable-isotope tracers: Use in studies of human tissue protein synthesis. https://app.cochat.ai/papers/10.1073/pnas.88.13.5892
The paper
Watt, P. W., Lindsay, Y., Scrimgeour, C. M., Chien, P. A., Gibson, J. N., Taylor, D. J., & Rennie, M. J. (1991). Isolation of aminoacyl-tRNA and its labeling with stable-isotope tracers: Use in studies of human tissue protein synthesis. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.88.13.5892

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.