Kinesin swivels to permit microtubule movement in any direction.
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Kinesin is a motor protein that uses the energy derived from ATP hydrolysis to transport organelles along microtubules. By analyzing the thermal fluctuation of microtubules tethered to glass surfaces by single molecules of kinesin, we have measured the torsional flexibility of the motor protein. The torsional stiffness of kinesin, (117 +/- 19) x 10(-24) N.m.rad-1 (mean +/- SEM), is so low that one kT of energy (approximately 4.1 x 10(-21) J at room temperature) is sufficient to twist a kinesin molecule through more than 360 degrees from its resting orientation. Consistent with this flexibility, motility assays show that one or more kinesin molecules can move a microtubule equally well in any direction. These results explain how a motor on the surface of an organelle can rapidly bind to and capture a microtubule irrespective of the organelle's orientation. Furthermore, the flexibility ensures that several motors can efficiently work together even though they are randomly oriented on the surface of an organelle rather than being in precise arrays like the motors of muscle and cilia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of a novel force-generating protein, kinesin, involved in microtubule-based motility
VALE, R., REESE, T., & SHEETZ, M. (1985) · Cell · doi:10.1016/s0092-8674(85)80099-4 · Cited by 1,993
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Movement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885
Self-citationHirokawa, N., Pfister, K. K., Yorifuji, H., Wagner, M. C., Brady, S. T., & Bloom, G. S. (1989) · Cell · doi:10.1016/0092-8674(89)90691-0 · Cited by 477
Kuznetsov, S. A., Vaisberg, Y. A., Rothwell, S. W., Murphy, D. B., & Gelfand, V. I. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)31301-7 · Cited by 95
Cited by
Force and velocity measured for single kinesin molecules
Svoboda, K., & Block, S. M. (1994) · Cell · doi:10.1016/0092-8674(94)90060-4 · Cited by 909
“It has also been suggested that the slowing of sperm heads moving in the centrifugal microscope may be due to something besides an inertial effect, and that the force thereby obtained is artifactually low (Hunt and Howard, 1993).”
BackgroundThe design plan of kinesin motors
Vale, R. D., & Fletterick, R. J. (1997) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.13.1.745 · Cited by 474
Microtubules and microtubule-associated proteins
Mandelkow, E., & Mandelkow, E.-M. (1995) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(95)80047-6 · Cited by 458
The Crystal Structure of Dimeric Kinesin and Implications for Microtubule-Dependent Motility
Kozielski, F., Sack, S., Marx, A., Thormählen, M., Schönbrunn, E., Biou, V, Thompson, A., Mandelkow, E.-M., & Mandelkow, E. (1997) · Cell · doi:10.1016/s0092-8674(00)80489-4 · Cited by 408
Hunter, A. W., Caplow, M., Coy, D. L., Hancock, W. O., Diez, S., Wordeman, L., & Howard, J. (2003) · Molecular Cell · doi:10.1016/s1097-2765(03)00049-2 · Cited by 386
Self-citation
Metadata
- Authors
- Hunt, A. J., & Howard, J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1993-12-15
- Volume
- 90
- Issue
- 24
- Pages
- 11653-11657
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2045319630
- Cited by
- 105
- References
- 5
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.