The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water.
Open accessAbstract
We report our experience using a noninvasive magnetic resonance technique for quantitative imaging of human brain perfusion at 1.5 T. This technique uses magnetically inverted arterial water as a freely diffusible blood flow tracer. A perfusion image is calculated from magnetic resonance images acquired with and without arterial blood inversion and from an image of the apparent spin-lattice relaxation time. Single-slice perfusion maps were obtained from nine volunteers with approximately 1 x 2 x 5-mm resolution in an acquisition time of 15 min. Analysis yielded average perfusion rates of 93 +/- 16 ml.100 g-1.min-1 for gray matter, 38 +/- 10 ml.100 g-1.min-1 for white matter, and 52 +/- 8 ml.100 g-1.min-1 for whole brain. Significant changes in perfusion were observed during hyperventilation and breath holding. This technique may be used for quantitative measurement of perfusion in human brain without the risks and expense of methods which use exogenous tracers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Cited by
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationJohnson, N. A., Jahng, G.-H., Weiner, M. W., Miller, B. L., Chui, H. C., Jagust, W. J., Gorno-Tempini, M. L., & Schuff, N. (2005) · Radiology · doi:10.1148/radiol.2343040197 · Cited by 587
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Arterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications
Haller, S., Zaharchuk, G., Thomas, D. L., Lovblad, K.-O., Barkhof, F., & Golay, X. (2016) · Radiology · doi:10.1148/radiol.2016150789 · Cited by 514
Metadata
- Authors
- Roberts, D. A., Detre, J. A., Bolinger, L., Insko, E. K., & Leigh, J. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1994-01-04
- Volume
- 91
- Issue
- 1
- Pages
- 33-37
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2147939139
- Cited by
- 177
- References
- 2
- FWCI
- 10.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water. https://app.cochat.ai/papers/10.1073/pnas.91.1.33
- The paper
- Roberts, D. A., Detre, J. A., Bolinger, L., Insko, E. K., & Leigh, J. S. (1994). Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.91.1.33
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.