A direct mechanism for sensing low oxygen levels by central neurons.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The cascade of cellular events that is triggered by low O2 levels in the central nervous system depends on initial sensing mechanisms that can be crucial in determining the overall cell response, adaptation, or injury. In this report, we demonstrate that the activity of an identified K+ channel is regulated directly by environmental O2. Membrane ionic currents were recorded from neurons of the neocortex and the substantia nigra and studied by using whole-cell or excised membrane patches. O2 deprivation reversibly induced an initial transient increase in whole-cell outward currents, and this was followed by a pronounced decrease in these currents. In cell-free excised membrane patches, lack of O2 reversibly inhibited a class of K+ channels that are inhibited by ATP and activated by Ca2+. K+ channel inhibition depended on pO2 level, with a 50% inhibition at approximately 11 torr (1 torr = 6.9 kPa). By the use of specific agents that chelate metal in metal-containing O2-sensing centers, including heme, nonheme iron, copper, and flavin, we also demonstrated that iron-center but not copper-center blockers inhibited the channel in excised patches in a similar fashion as low pO2. These results strongly suggest that K+ channel activity is modulated during O2 deprivation by nonheme iron-containing proteins that are associated with channel molecules, thus providing evidence for a direct O2-sensing mechanism in neuronal membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross, A. R., & Jones, O. T. G. (1986) · Biochemical Journal · doi:10.1042/bj2370111 · Cited by 551
Cited by
PAS Domains: Internal Sensors of Oxygen, Redox Potential, and Light
Taylor, B. L., & Zhulin, I. B. (1999) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.63.2.479-506.1999 · Cited by 1,632
“Oxygen-sensitive ion channels are involved in several cardiocirculatory and respiratory responses to low oxygen levels in fetal and adult life (36, 258) and are associated with the pathophysiology of hypertension, cardiac arrhythmias, and ischemic neuronal damage (60, 115, 144, 245).”
BackgroundCellular Mechanism of Oxygen Sensing
López-Barneo, J., Pardal, R., & Ortega-Sáenz, P. (2001) · Annual Review of Physiology · doi:10.1146/annurev.physiol.63.1.259 · Cited by 544
Hemoxygenase-2 Is an Oxygen Sensor for a Calcium-Sensitive Potassium Channel
Williams, S. E. J., Wootton, P., Mason, H. S., Bould, J., Iles, D. E., Riccardi, D., Peers, C., & Kemp, P. J. (2004) · Science · doi:10.1126/science.1105010 · Cited by 458
Hypoxic pulmonary vasoconstriction
Moudgil, R., Michelakis, E. D., & Archer, S. L. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00733.2004 · Cited by 454
Hypoxemia, oxygen content, and the regulation of cerebral blood flow
Hoiland, R. L., Bain, A. R., Rieger, M. G., Bailey, D. M., & Ainslie, P. N. (2016) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00270.2015 · Cited by 255
Metadata
- Authors
- Jiang, C., & Haddad, G. G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1994-07-19
- Volume
- 91
- Issue
- 15
- Pages
- 7198-7201
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2009789887
- Cited by
- 116
- References
- 1
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.