The DOI matches its Crossref record.
Magnetic resonance microscopy of mouse embryos.
Open accessAbstract
The increased use of the mouse as a model for various aspects of mammalian biology has caused a renewed interest in developing strategies for examining and comparing normal and abnormal mouse embryonic development and anatomy. In this study, we have explored the use of magnetic resonance microscopy as a tool for these purposes. Techniques for the fixation, embedding, perfusion, and image acquisition of mouse embryos are described. The perfusion of bovine serum albumin-diethylenetriamine pentaacetic anhydride-gadolinium as a contrast agent enhances images of the developing embryonic vasculature during critical stages of organogenesis and allows for comparisons when embryos have been treated with teratogens such as retinoic acid. The acquired three-dimensional data sets are available for archiving, distributing, and postacquisition manipulations such as computer segmentation of anatomical structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In vivo magnetic resonance imaging of transgene expression
Weissleder, R., Moore, A., Mahmood, U., Bhorade, R., Benveniste, H., Chiocca, E. A., & Basilion, J. P. (2000) · Nature Medicine · doi:10.1038/73219 · Cited by 776
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Molecular Imaging: Exploring the Next Frontier
Weissleder, R. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se18609 · Cited by 339
Petiet, A. E., Kaufman, M. H., Goddeeris, M. M., Brandenburg, J., Elmore, S. A., & Johnson, G. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805747105 · Cited by 120
Self-citationThe development of the heart and microcirculation: role of shear stress
Poelmann, R. E., Gittenberger-de Groot, A. C., & Hierck, B. P. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0304-4 · Cited by 62
Metadata
- Authors
- Smith, B. R., Johnson, G. A., Groman, E. V., & Linney, E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1994-04-26
- Volume
- 91
- Issue
- 9
- Pages
- 3530-3533
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2009407478
- Cited by
- 164
- References
- 0
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance microscopy of mouse embryos. https://app.cochat.ai/papers/10.1073/pnas.91.9.3530
- The paper
- Smith, B. R., Johnson, G. A., Groman, E. V., & Linney, E. (1994). Magnetic resonance microscopy of mouse embryos. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.91.9.3530
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.