Linking genome and proteome by mass spectrometry: Large-scale identification of yeast proteins from two dimensional gels
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
The function of many of the uncharacterized open reading frames discovered by genomic sequencing can be determined at the level of expressed gene products, the proteome. However, identifying the cognate gene from minute amounts of protein has been one of the major problems in molecular biology. Using yeast as an example, we demonstrate here that mass spectrometric protein identification is a general solution to this problem given a completely sequenced genome. As a first screen, our strategy uses automated laser desorption ionization mass spectrometry of the peptide mixtures produced by in-gel tryptic digestion of a protein. Up to 90% of proteins are identified by searching sequence data bases by lists of peptide masses obtained with high accuracy. The remaining proteins are identified by partially sequencing several peptides of the unseparated mixture by nanoelectrospray tandem mass spectrometry followed by data base searching with multiple peptide sequence tags. In blind trials, the method led to unambiguous identification in all cases. In the largest individual protein identification project to date, a total of 150 gel spots—many of them at subpicomole amounts—were successfully analyzed, greatly enlarging a yeast two-dimensional gel data base. More than 32 proteins were novel and matched to previously uncharacterized open reading frames in the yeast genome. This study establishes that mass spectrometry provides the required throughput, the certainty of identification, and the general applicability to serve as the method of choice to connect genome and proteome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,995
Self-citationEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Goffeau, A., Barrell, B. G., Bussey, H., Davis, R. W., Dujon, B., Feldmann, H., Galibert, F., Hoheisel, J. D., Jacq, C., Johnston, M., et al. (1996) · Science · doi:10.1126/science.274.5287.546 · Cited by 4,263
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Self-citationFemtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry
Wilm, M., Shevchenko, A., Houthaeve, T., Breit, S., Schweigerer, L., Fotsis, T., & Mann, M. (1996) · Nature · doi:10.1038/379466a0 · Cited by 1,680
Self-citationRapid identification of proteins by peptide-mass fingerprinting
Pappin, D. J. C., Hojrup, P., & Bleasby, A. J. (1993) · Current Biology · doi:10.1016/0960-9822(93)90195-t · Cited by 1,615
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Self-citationHenzel, W. J., Billeci, T. M., Stults, J. T., Wong, S. C., Grimley, C., & Watanabe, C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5011 · Cited by 1,305
Protein sequencing by tandem mass spectrometry.
Hunt, D. F., Yates, J. R., Shabanowitz, J., Winston, S., & Hauer, C. R. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6233 · Cited by 1,180
Contributions of mass spectrometry to peptide and protein structure
Biemann, K. (1988) · Biological Mass Spectrometry · doi:10.1002/bms.1200160119 · Cited by 1,015
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Self-citationUse of mass spectrometric molecular weight information to identify proteins in sequence databases
Mann, M., Højrup, P., & Roepstorff, P. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220605 · Cited by 931
Self-citationWilkins, M. R., Pasquali, C., Appel, R. D., Ou, K., Golaz, O., Sanchez, J.-C., Yan, J. X., Gooley, A. A., Hughes, G., Humphery-Smith, I., et al. (1996) · Nature Biotechnology · doi:10.1038/nbt0196-61 · Cited by 834
Vorm, O., Roepstorff, P., & Mann, M. (1994) · Analytical Chemistry · doi:10.1021/ac00091a044 · Cited by 687
Self-citationPeptide Mass Maps: A Highly Informative Approach to Protein Identification
Yates, J. R., Speicher, S., Griffin, P. R., & Hunkapiller, T. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1514 · Cited by 676
Protein Identification by Mass Profile Fingerprinting
James, P., Quadroni, M., Carafoli, E., & Gonnet, G. (1993) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1993.2009 · Cited by 596
Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry
Vestal, M. L., Juhasz, P., & Martin, S. A. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290091115 · Cited by 497
Brown, R. S., & Lennon, J. J. (1995) · Analytical Chemistry · doi:10.1021/ac00109a015 · Cited by 371
Jensen, O. N., Podtelejnikov, A., & Mann, M. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199608)10:11<1371::aid-rcm682>3.0.co;2-5 · Cited by 297
Self-citationParent Ion Scans of Unseparated Peptide Mixtures
Wilm, M., Neubauer, G., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950875+ · Cited by 250
Self-citationElectrospray mass spectrometry for protein characterization
Mann, M., & Wilm, M. (1995) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)89019-2 · Cited by 214
Self-citationClauser, K. R., Hall, S. C., Smith, D. M., Webb, J. W., Andrews, L. E., Tran, H. M., Epstein, L. B., & Burlingame, A. L. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.11.5072 · Cited by 205
From Genome to Proteome: Looking at a Cell's Proteins
Kahn, P. (1995) · Science · doi:10.1126/science.270.5235.369 · Cited by 184
Whittal, R. M., & Li, L. (1995) · Analytical Chemistry · doi:10.1021/ac00109a007 · Cited by 172
Vorm, O., & Mann, M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80013-8 · Cited by 144
Self-citationJensen, O. N., Houthaeve, T., Shevchenko, A., Cudmore, S., Ashford, T., Mann, M., Griffiths, G., & Krijnse Locker, J. (1996) · Journal of Virology · doi:10.1128/jvi.70.11.7485-7497.1996 · Cited by 115
Self-citationDevelopments in matrix-assisted laser desorption/ionization peptide mass spectrometry
Mann, M., & Talbo, G. H. (1996) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(96)80089-9 · Cited by 110
Self-citationMass Spectrometric Methods for Protein Sequencing
BIEMANN, K. (1986) · Analytical Chemistry · doi:10.1021/ac00126a001 · Cited by 105
Two‐Dimensional protein map of Saccharomyces cerevisiae: Construction of a gene–protein index
Boucherie, H., Monribot, C., Perrot, M., Dujardin, G., Kermorgant, M., & Słonimski, P. P. (1995) · Yeast · doi:10.1002/yea.320110702 · Cited by 94
Self-citationHologram-based refractive index detector for capillary electrophoresis: separation of metal ions
Krattiger, B., Bruin, G. J. M., & Bruno, A. E. (1994) · Analytical Chemistry · doi:10.1021/ac00073a003 · Cited by 89
Patterson, S. D., Thomas, D., & Bradshaw, R. A. (1996) · Electrophoresis · doi:10.1002/elps.1150170509 · Cited by 81
Wheeler, C., Berry, S., Wilkins, M. R., Corbett, J. M., Ou, K., Gooley, A. A., Humphery‐Smith, I., Williams, K. L., & Dunn, M. J. (1996) · Electrophoresis · doi:10.1002/elps.1150170329 · Cited by 59
Jensen, O. N., Vorm, O., & Mann, M. (1996) · Electrophoresis · doi:10.1002/elps.1150170516 · Cited by 47
Self-citationSequence Database Searching by Mass Spectrometric Data
Mann, M. (1994) · Wiley eBooks · doi:10.1002/9783527615711.ch14 · Cited by 25
Self-citationSagliocco, F. A., Guillemot, J.-C., Monribot, C., Capdevielle, J., Perrot, M., Ferrán, E. A., Ferrara, P., & Boucherie, H. (1996) · PubMed · doi:10.1002/(sici)1097-0061(199612)12:15%3c1519::aid-yea47%3e3.0.co;2-m · Cited by 25
Self-citation
Cited by
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Goffeau, A., Barrell, B. G., Bussey, H., Davis, R. W., Dujon, B., Feldmann, H., Galibert, F., Hoheisel, J. D., Jacq, C., Johnston, M., et al. (1996) · Science · doi:10.1126/science.274.5287.546 · Cited by 4,263
Correlation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Locating proteins in the cell using TargetP, SignalP and related tools
Emanuelsson, O., Brunak, S., von Heijne, G., & Nielsen, H. (2007) · Nature Protocols · doi:10.1038/nprot.2007.131 · Cited by 3,188
Metadata
- Authors
- Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1996-12-10
- Volume
- 93
- Issue
- 25
- Pages
- 14440-14445
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2126024920
- Cited by
- 1,427
- References
- 35
- FWCI
- 37.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.