The DOI matches its Crossref record.
Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography
Open accessAbstract
Studies investigating normal and abnormal cardiac development are frequently limited by an inability to assess cardiovascular function within the intact organism. In this work, optical coherence tomography (OCT), a new method of micron-scale, noninvasive imaging based on the measurement of backscattered infrared light, was introduced for the high resolution assessment of structure and function in the developing Xenopus laevis cardiovascular system. Microstructural details, such as ventricular size and wall positions, were delineated with OCT at 16-μm resolution and correlated with histology. Three-dimensional representation of the cardiovascular system also was achieved by repeated cross-sectional imaging at intervals of 25 μm. In addition to structural information, OCT provides high speed in vivo axial ranging and imaging, allowing quantitative dynamic activity, such as ventricular ejection fraction, to be assessed. The sensitivity of OCT for dynamic assessment was demonstrated with an inotropic agent that altered cardiac function and dimensions. Optical coherence tomography is an attractive new technology for assessing cardiovascular development because of its high resolution, its ability to image through nontransparent structures, and its inexpensive portable design. In vivo and in vitro imaging are performed at a resolution approaching that of histopathology without the need for animal killing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
In vivo video rate optical coherence tomography
Rollins, A. M., Kulkarni, M. D., Yazdanfar, S., Ung-arunyawee, R., & Izatt, J. A. (1998) · Optics Express · doi:10.1364/oe.3.000219 · Cited by 414
In vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Self-citation
Metadata
- Authors
- Boppart, S. A., Tearney, G. J., Bouma, B. E., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1997-04-29
- Volume
- 94
- Issue
- 9
- Pages
- 4256-4261
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2080606146
- Cited by
- 174
- References
- 0
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography. https://app.cochat.ai/papers/10.1073/pnas.94.9.4256
- The paper
- Boppart, S. A., Tearney, G. J., Bouma, B. E., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1997). Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.94.9.4256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.