The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A microfabricated device for sizing and sorting DNA molecules
Open accessAbstract
We have demonstrated a microfabricated single-molecule DNA sizing device. This device does not depend on mobility to measure molecule size, is 100 times faster than pulsed-field gel electrophoresis, and has a resolution that improves with increasing DNA length. It also requires a million times less sample than pulsed-field gel electrophoresis and has comparable resolution for large molecules. Here we describe the fabrication and use of the single-molecule DNA sizing device for sizing and sorting DNA restriction digests and ladders spanning 2–200 kbp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Fabrication of Submicrometer Features on Curved Substrates by Microcontact Printing
Jackman, R. J., Wilbur, J. L., & Whitesides, G. M. (1995) · Science · doi:10.1126/science.7624795 · Cited by 434
A new strategy for genome sequencing
Venter, J. C., Smith, H. O., & Hood, L. (1996) · Nature · doi:10.1038/381364a0 · Cited by 342
Self-Sorting of White Blood Cells in a Lattice
Carlson, R. H., Gabel, C. V., Chan, S. S., et al. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.2149 · Cited by 117
Pulsed-Field Gel Electrophoresis
Burmeister, M., & Ulanovsky, L. E. (1992) · Humana Press eBooks · doi:10.1385/0896032299 · Cited by 29
Pulsed field gel electrophoresis; Protocols, methods and theories
(1993) · International Journal of Biochemistry · doi:10.1016/0020-711x(93)90640-z · Cited by 24
Cited by
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationLab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Metadata
- Authors
- Chou, H.-P., Spence, C., Scherer, A., & Quake, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-01-05
- Volume
- 96
- Issue
- 1
- Pages
- 11-13
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2038908517
- Cited by
- 274
- References
- 9
- FWCI
- 21.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfabricated device for sizing and sorting DNA molecules. https://app.cochat.ai/papers/10.1073/pnas.96.1.11
- The paper
- Chou, H.-P., Spence, C., Scherer, A., & Quake, S. (1999). A microfabricated device for sizing and sorting DNA molecules. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.96.1.11
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.