The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A microfabricated device for sizing and sorting DNA molecules
Open accessAbstract
We have demonstrated a microfabricated single-molecule DNA sizing device. This device does not depend on mobility to measure molecule size, is 100 times faster than pulsed-field gel electrophoresis, and has a resolution that improves with increasing DNA length. It also requires a million times less sample than pulsed-field gel electrophoresis and has comparable resolution for large molecules. Here we describe the fabrication and use of the single-molecule DNA sizing device for sizing and sorting DNA restriction digests and ladders spanning 2–200 kbp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Fabrication of Submicrometer Features on Curved Substrates by Microcontact Printing
Jackman, R. J., Wilbur, J. L., & Whitesides, G. M. (1995) · Science · doi:10.1126/science.7624795 · Cited by 434
A new strategy for genome sequencing
Venter, J. C., Smith, H. O., & Hood, L. (1996) · Nature · doi:10.1038/381364a0 · Cited by 342
Self-Sorting of White Blood Cells in a Lattice
Carlson, R. H., Gabel, C. V., Chan, S. S., et al. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.2149 · Cited by 117
Pulsed-Field Gel Electrophoresis
Burmeister, M., & Ulanovsky, L. E. (1992) · Humana Press eBooks · doi:10.1385/0896032299 · Cited by 29
Pulsed field gel electrophoresis; Protocols, methods and theories
(1993) · International Journal of Biochemistry · doi:10.1016/0020-711x(93)90640-z · Cited by 24
Cited by
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationLab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Direct Ink Writing of 3D Functional Materials
Lewis, J. A. (2006) · Advanced Functional Materials · doi:10.1002/adfm.200600434 · Cited by 1,740
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Self-citationSeparation of Long DNA Molecules in a Microfabricated Entropic Trap Array
Han, J., & Craighead, H. G. (2000) · Science · doi:10.1126/science.288.5468.1026 · Cited by 924
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Self-citationRecent progress in nanoimprint technology and its applications
Guo, L. J. (2004) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/37/11/r01 · Cited by 733
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Chaotic mixing in three-dimensional microvascular networks fabricated by direct-write assembly
Therriault, D., White, S. R., & Lewis, J. A. (2003) · Nature Materials · doi:10.1038/nmat863 · Cited by 707
Beyond Watson and Crick: DNA Methylation and Molecular Enzymology of DNA Methyltransferases
Jeltsch, A. (2002) · ChemBioChem · doi:10.1002/1439-7633(20020402)3:4<274::aid-cbic274>3.0.co;2-s · Cited by 610
Convery, N., & Gadegaard, N. (2019) · Micro and Nano Engineering · doi:10.1016/j.mne.2019.01.003 · Cited by 602
Hansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.262485199 · Cited by 517
Self-citationDirect writing in three dimensions
Lewis, J. A., & Gratson, G. M. (2004) · Materials Today · doi:10.1016/s1369-7021(04)00344-x · Cited by 507
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Fabrication Methods for Microfluidic Devices: An Overview
Scott, S., & Ali, Z. (2021) · Micromachines · doi:10.3390/mi12030319 · Cited by 479
Micro- and nanofluidics for DNA analysis
Tegenfeldt, J. O., Prinz, C., Huang, R. L., Austin, R. H., Chou, S. Y., Cox, E. C., Sturm, J. C., & Cao, H. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2526-0 · Cited by 320
Combinatorial Heterogeneous Catalysis—A New Path in an Old Field
Senkan, S. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010119)40:2<312::aid-anie312>3.0.co;2-i · Cited by 311
Multiscale and Multistep Ordering of Flow-Induced Nucleation of Polymers
Cui, K., Ma, Z., Tian, N., Su, F., Liu, D., & Li, L. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00500 · Cited by 309
Moving smaller in drug discovery and delivery
LaVan, D. A., Lynn, D. M., & Langer, R. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd707 · Cited by 289
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Metadata
- Authors
- Chou, H.-P., Spence, C., Scherer, A., & Quake, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-01-05
- Volume
- 96
- Issue
- 1
- Pages
- 11-13
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2038908517
- Cited by
- 274
- References
- 9
- FWCI
- 21.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.