Multiplex detection of four pathogenic retroviruses using molecular beacons
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We describe a multiplex nucleic acid assay that identifies and determines the abundance of four different pathogenic retroviruses (HIV-1, HIV-2, and human T-lymphotrophic virus types I and II). Retroviral DNA sequences are amplified in a single, sealed tube by simultaneous PCR assays, and the resulting amplicons are detected in real time by the hybridization of four differently colored, amplicon-specific molecular beacons. The color of the fluorescence generated in the course of amplification identifies which retroviruses are present, and the number of thermal cycles required for the intensity of each color to rise significantly above background provides an accurate measure of the number of copies of each retroviral sequence that were present originally in the sample. Fewer than 10 retroviral genomes can be detected. Moreover, 10 copies of a rare retrovirus can be detected in the presence of 100,000 copies of an abundant retrovirus. Ninety-six samples can be analyzed in 3 hr on a single plate, and the use of a closed-tube format eliminates crossover contamination. Utilizing previously well characterized clinical samples, we demonstrate that each of the pathogenic retroviruses can be identified correctly and no false positives occur. This assay enables the rapid and reliable screening of donated blood and transplantable tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
[21] Specific synthesis of DNA in vitro via a polymerase-catalyzed chain reaction
Mullis, K. B., & Faloona, F. A. (1987) · Methods in Enzymology · doi:10.1016/0076-6879(87)55023-6 · Cited by 5,694
Poiesz, B. J., Ruscetti, F. W., Gazdar, A. F., Bunn, P. A., Minna, J. D., & Gallo, R. C. (1980) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.77.12.7415 · Cited by 5,043
Self-citationMolecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Self-citationPopovic, M., Sarngadharan, M. G., Read, E., & Gallo, R. C. (1984) · Science · doi:10.1126/science.6200935 · Cited by 3,535
Avoiding false positives with PCR
Kwok, S., & Higuchi, R. (1989) · Nature · doi:10.1038/339237a0 · Cited by 3,441
Complete nucleotide sequence of the AIDS virus, HTLV-III
Ratner, L., Haseltine, W., Patarca, R., Livak, K. J., Starcich, B., Josephs, S. F., Doran, E. R., Rafalski, J. A., Whitehorn, E. A., Baumeister, K., et al. (1985) · Nature · doi:10.1038/313277a0 · Cited by 2,245
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
On Finding All Suboptimal Foldings of an RNA Molecule
Zuker, M. (1989) · Science · doi:10.1126/science.2468181 · Cited by 2,005
Mutation detection and single-molecule counting using isothermal rolling-circle amplification
Lizardi, P. M., Huang, X., Zhu, Z., Bray-Ward, P., Thomas, D. C., & Ward, D. C. (1998) · Nature Genetics · doi:10.1038/898 · Cited by 1,442
Research works printed but not linked: 6
- 10.1093/clinchem/39.9.1927 · doi:10.1093/clinchem/39.9.1927
- 10.1016/0166-0934(94)90053-1 · doi:10.1016/0166-0934(94)90053-1
- 10.1126/science.3375832 · doi:10.1126/science.3375832
- R Higuchi, C Fockler, G Dollinger, R Watson Biotechnology 11, 1026–1030 (1993).
- J L Love, C C Marchioli, S Dube, V Bryz-Gornia, T P Loughran, J B Glaser, E Esteban, L Feldman, J F Ferrer, B J Poiesz J AIDS Hum Retrovirol 18, 178–185 (1998).
- 10.1093/clinchem/44.3.482 · doi:10.1093/clinchem/44.3.482
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
An Overview of Real-Time Quantitative PCR: Applications to Quantify Cytokine Gene Expression
Giulietti, A., Overbergh, L., Valckx, D., Decallonne, B., Bouillon, R., & Mathieu, C. (2001) · Methods · doi:10.1006/meth.2001.1261 · Cited by 1,411
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Single-mismatch detection using gold-quenched fluorescent oligonucleotides
Dubertret, B., Calame, M., & Libchaber, A. J. (2001) · Nature Biotechnology · doi:10.1038/86762 · Cited by 1,239
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559 · Cited by 961
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Quantification using real-time PCR technology: applications and limitations
Klein, D. (2002) · Trends in Molecular Medicine · doi:10.1016/s1471-4914(02)02355-9 · Cited by 762
Basic principles of real-time quantitative PCR
Arya, M., Shergill, I. S., Williamson, M., Gommersall, L., Arya, N., & Patel, H. R. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.2.209 · Cited by 627
Simultaneous Detection of Influenza Viruses A and B Using Real-Time Quantitative PCR
van Elden, L. J. R., Nijhuis, M., Schipper, P., Schuurman, R., & van Loon, A. M. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.1.196-200.2001 · Cited by 456
DNA Probes Using Fluorescence Resonance Energy Transfer (FRET): Designs and Applications
Didenko, V. V. (2001) · BioTechniques · doi:10.2144/01315rv02 · Cited by 408
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559-570.2000 · Cited by 964
Real‐time PCR (qPCR) primer design using free online software
Thornton, B., & Basu, C. (2011) · Biochemistry and Molecular Biology Education · doi:10.1002/bmb.20461 · Cited by 350
Hybridization kinetics and thermodynamics of molecular beacons
Tsourkas, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg212 · Cited by 316
Molecular Aptamer Beacons for Real-Time Protein Recognition
Li, J. J., Fang, X., & Tan, W. (2002) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2002.6581 · Cited by 294
Fluorescent Biosensors Based on Single-Molecule Counting
Ma, F., Li, Y., Tang, B., & Zhang, C.-Y. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00237 · Cited by 288
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
Rouet, F., Ekouevi, D. K., Chaix, M.-L., Burgard, M., Inwoley, A., Tony, T. D., Danel, C., Anglaret, X., Leroy, V., Msellati, P., et al. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.6.2709-2717.2005 · Cited by 234
“Moreover, plasma HIV-1 RNA has been assessed by real-time PCR for multiplex nucleic acid amplification testing in blood donations (25, 26, 40) and for HAART monitoring in HIV-1-seropositive patients (15, 30).”
MethodEnzymatic signal amplification of molecular beacons for sensitive DNA detection
Li, J. J., Chu, Y., Lee, B. Y.-H., & Xie, X. S. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn033 · Cited by 226
Quantitation of Viral Load Using Real-Time Amplification Techniques
Niesters, H. G. M. (2001) · Methods · doi:10.1006/meth.2001.1264 · Cited by 220
El-Hajj, H. H., Marras, S. A. E., Tyagi, S., Kramer, F. R., & Alland, D. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.11.4131-4137.2001 · Cited by 180
“Although the spectrofluorometric instruments used to carry out these assays are relatively expensive, they are becoming common in clinical diagnostic laboratories as a result of an increasing awareness of the broad applicability of closed-tube gene amplification techniques (20, 25, 30 ).”
MethodSelf-citation
Metadata
- Authors
- Vet, J. A. M., Majithia, A. R., Marras, S. A. E., Tyagi, S., Dube, S., Poiesz, B. J., & Kramer, F. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-05-25
- Volume
- 96
- Issue
- 11
- Pages
- 6394-6399
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2018466980
- Cited by
- 322
- References
- 43
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.