Sorting by diffusion: An asymmetric obstacle course for continuous molecular separation
Open accessThe DOI matches its Crossref record.
Abstract
A separation technique employing a microfabricated sieve has been demonstrated by observing the motion of DNA molecules of different size. The sieve consists of a two-dimensional lattice of obstacles whose asymmetric disposition rectifies the Brownian motion of molecules driven through the device, causing them to follow paths that depend on their diffusion coefficient. A nominal 6% resolution by length of DNA molecules in the size range 15–30 kbp may be achieved in a 4-inch (10-cm) silicon wafer. The advantage of this method is that samples can be loaded and sorted continuously, in contrast to the batch mode commonly used in gel electrophoresis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Self-citationArtificial Brownian motors: Controlling transport on the nanoscale
Hänggi, P., & Marchesoni, F. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.387 · Cited by 1,573
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
Self-citationSeparation of Long DNA Molecules in a Microfabricated Entropic Trap Array
Han, J., & Craighead, H. G. (2000) · Science · doi:10.1126/science.288.5468.1026 · Cited by 924
Self-citationContinuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Fu, J., Schoch, R. B., Stevens, A. L., Tannenbaum, S. R., & Han, J. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.206 · Cited by 334
Micro- and nanofluidics for DNA analysis
Tegenfeldt, J. O., Prinz, C., Huang, R. L., Austin, R. H., Chou, S. Y., Cox, E. C., Sturm, J. C., & Cao, H. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2526-0 · Cited by 320
Self-citationMolecular sieving using nanofilters: Past, present and future
Han, J., Fu, J., & Schoch, R. B. (2008) · Lab Chip · doi:10.1039/b714128a · Cited by 293
Dorfman, K. D., King, S. B., Olson, D. W., Thomas, J. D. P., & Tree, D. R. (2013) · Chemical Reviews · doi:10.1021/cr3002142 · Cited by 193
DNA manipulation, sorting, and mapping in nanofluidic systems
Levy, S. L., & Craighead, H. G. (2010) · Chemical Society Reviews · doi:10.1039/b820266b · Cited by 178
Self-citationDroplet-based single cell RNAseq tools: a practical guide
Salomon, R., Kaczorowski, D., Valdes-Mora, F., Nordon, R. E., Neild, A., Farbehi, N., Bartonicek, N., & Gallego-Ortega, D. (2019) · Lab on a Chip · doi:10.1039/c8lc01239c · Cited by 109
Metadata
- Authors
- Chou, C.-F., Bakajin, O., Turner, S. W. P., Duke, T. A. J., Chan, S. S., Cox, E. C., Craighead, H. G., & Austin, R. H.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-11-23
- Volume
- 96
- Issue
- 24
- Pages
- 13762-13765
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2052278186
- Cited by
- 196
- References
- 0
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.