Detection of emphysema in rat lungs by using magnetic resonance measurements of 3 He diffusion
Open accessAbstract
Emphysema is a pulmonary disease characterized by alveolar wall destruction, resulting in enlargement of gas exchange spaces without fibrosis. This condition is a part of chronic obstructive pulmonary disease (COPD), which causes 3.5% of deaths worldwide [Anonymous (1990) World Health Stat. Q. Special , 1–51] and contributes greatly to the global burden of disease [Murray, C. J. & Lopez, A. D. (1996) Science 274, 740–743]. Alveolar regeneration has been shown in animal models and could have potential for clinical treatment of early-stage emphysema. However, current techniques for detection of emphysema are not sensitive at the initial stages. Early-stage human panacinar emphysema is modeled in elastase-treated animals. Here, we provide an in vivo imaging method for differentiating normal and emphysematous rat lungs by measuring the apparent diffusion coefficient (ADC) of hyperpolarized 3 He by using magnetic resonance imaging. These data show that the ADC is significantly larger in elastase-treated rats, indicating alveolar expansion. Whereas these rats were clinically asymptomatic, conventional histology confirmed presence of injury. Our results indicate that measurement of the hyperpolarized 3 He ADC can be a valuable research tool and has potential application in the clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
Optimized 3D ultrashort echo time pulmonary MRI
Johnson, K. M., Fain, S. B., Schiebler, M. L., & Nagle, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24570 · Cited by 322
Narayanan, M., Owers-Bradley, J., Beardsmore, C. S., Mada, M., Ball, I., Garipov, R., Panesar, K. S., Kuehni, C. E., Spycher, B. D., Williams, S. E., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201107-1348oc · Cited by 293
The see-through medaka: a fish model that is transparent throughout life
Wakamatsu, Y., Pristyazhnyuk, S., Kinoshita, M., Tanaka, M., & Ozato, K. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181204298 · Cited by 193
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Metadata
- Authors
- Chen, X. J., Hedlund, L. W., Möller, H. E., Chawla, M. S., Maronpot, R. R., & Johnson, G. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-10-10
- Volume
- 97
- Issue
- 21
- Pages
- 11478-11481
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2107347492
- Cited by
- 165
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of emphysema in rat lungs by using magnetic resonance measurements of 3 He diffusion. https://app.cochat.ai/papers/10.1073/pnas.97.21.11478
- The paper
- Chen, X. J., Hedlund, L. W., Möller, H. E., Chawla, M. S., Maronpot, R. R., & Johnson, G. A. (2000). Detection of emphysema in rat lungs by using magnetic resonance measurements of 3 He diffusion. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.97.21.11478
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.