The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Ultrasensitive magnetic biosensor for homogeneous immunoassay
Open accessAbstract
A technique is described for specific, sensitive, quantitative, and rapid detection of biological targets by using superparamagnetic nanoparticles and a “microscope” based on a high-transition temperature dc superconducting quantum interference device (SQUID). In this technique, a mylar film to which the targets have been bound is placed on the microscope. The film, at room temperature and atmospheric pressure, is typically 40 μm from the SQUID, which is at 77 K in a vacuum. A suspension of magnetic nanoparticles carrying antibodies directed against the target is added to the mixture in the well, and 1-s pulses of magnetic field are applied parallel to the SQUID. In the presence of this aligning field the nanoparticles develop a net magnetization, which relaxes when the field is turned off. Unbound nanoparticles relax rapidly by Brownian rotation and contribute no measurable signal. Nanoparticles that are bound to the target on the film are immobilized and undergo Néel relaxation, producing a slowly decaying magnetic flux, which is detected by the SQUID. The ability to distinguish between bound and unbound labels allows one to run homogeneous assays, which do not require separation and removal of unbound magnetic particles. The technique has been demonstrated with a model system of liposomes carrying the FLAG epitope. The SQUID microscope requires no more than (5 ± 2) × 10 4 magnetic nanoparticles to register a reproducible signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blakemore, R. (1975) · Science · doi:10.1126/science.170679 · Cited by 1,707
Scientific and Clinical Applications of Magnetic Carriers
(1997) · Springer eBooks · doi:10.1007/978-1-4757-6482-6 · Cited by 1,032
Use of magnetic techniques for the isolation of cells
Šafařı́k, I., & Šafařı́ková, M. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00338-7 · Cited by 617
[31] Tackling the protease problem in Saccharomyces cerevisiae
Jones, E. W. (1991) · Methods in Enzymology · doi:10.1016/0076-6879(91)94034-a · Cited by 437
High-transition-temperature superconducting quantum interference devices
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.631 · Cited by 396
Self-citationEnpuku, K., Minotani, T., Gima, T., Kuroki, Y., Itoh, Y., Yamashita, M., Katakura, Y., & Kuhara, S. (1999) · Japanese Journal of Applied Physics · doi:10.1143/jjap.38.l1102 · Cited by 131
David, N. E., Gee, M., Andersen, B. B., et al. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.24.15553 · Cited by 98
High-transition temperature superconducting quantum interference device microscope
Lee, T. S., Dantsker, E., & Clarke, J. L. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147570 · Cited by 96
Self-citation
Cited by
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
The use of nanocrystals in biological detection
Alivisatos, P. (2004) · Nature Biotechnology · doi:10.1038/nbt927 · Cited by 3,008
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Nanotech approaches to drug delivery and imaging
Sahoo, S. K., & Labhasetwar, V. (2003) · Drug Discovery Today · doi:10.1016/s1359-6446(03)02903-9 · Cited by 1,203
Metadata
- Authors
- Chemla, Y. R., Grossman, H. L., Poon, Y., McDermott, R., Stevens, R., Alper, M. D., & Clarke, J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-12-19
- Volume
- 97
- Issue
- 26
- Pages
- 14268-14272
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1987428883
- Cited by
- 421
- References
- 8
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.