The DOI matches its Crossref record.
Whole-body optical imaging of green fluorescent protein-expressing tumors and metastases
Open accessAbstract
We have imaged, in real time, fluorescent tumors growing and metastasizing in live mice. The whole-body optical imaging system is external and noninvasive. It affords unprecedented continuous visual monitoring of malignant growth and spread within intact animals. We have established new human and rodent tumors that stably express very high levels of the Aequorea victoria green fluorescent protein (GFP) and transplanted these to appropriate animals. B16F0-GFP mouse melanoma cells were injected into the tail vein or portal vein of 6-week-old C57BL/6 and nude mice. Whole-body optical images showed metastatic lesions in the brain, liver, and bone of B16F0-GFP that were used for real time, quantitative measurement of tumor growth in each of these organs. The AC3488-GFP human colon cancer was surgically implanted orthotopically into nude mice. Whole-body optical images showed, in real time, growth of the primary colon tumor and its metastatic lesions in the liver and skeleton. Imaging was with either a trans-illuminated epifluorescence microscope or a fluorescence light box and thermoelectrically cooled color charge-coupled device camera. The depth to which metastasis and micrometastasis could be imaged depended on their size. A 60-μm diameter tumor was detectable at a depth of 0.5 mm whereas a 1,800-μm tumor could be visualized at 2.2-mm depth. The simple, noninvasive, and highly selective imaging of growing tumors, made possible by strong GFP fluorescence, enables the detailed imaging of tumor growth and metastasis formation. This should facilitate studies of modulators of cancer growth including inhibition by potential chemotherapeutic agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Senescence Program Controlled by p53 and p16INK4a Contributes to the Outcome of Cancer Therapy
Schmitt, C. A., Fridman, J. S., Yang, M., Lee, S., Baranov, E., Hoffman, R. M., & Lowe, S. W. (2002) · Cell · doi:10.1016/s0092-8674(02)00734-1 · Cited by 1,050
Self-citationTroy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B. (2004) · Molecular Imaging · doi:10.1162/153535004773861688 · Cited by 418
Artemov, D., Mori, N., Okollie, B., & Bhujwalla, Z. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10406 · Cited by 351
Mansfield, J. R., Gossage, K. W., Hoyt, C. C., & Levenson, R. M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2032458 · Cited by 311
The see-through medaka: a fish model that is transparent throughout life
Wakamatsu, Y., Pristyazhnyuk, S., Kinoshita, M., Tanaka, M., & Ozato, K. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181204298 · Cited by 193
Metadata
- Authors
- Yang, M., Baranov, E., Jiang, P., Sun, F.-X., Li, X.-M., Li, L., Hasegawa, S., Bouvet, M., Al-Tuwaijri, M., Chishima, T., Shimada, H., Moossa, A. R., Penman, S., & Hoffman, R. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-02
- Volume
- 97
- Issue
- 3
- Pages
- 1206-1211
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2108447763
- Cited by
- 514
- References
- 0
- FWCI
- 35.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Whole-body optical imaging of green fluorescent protein-expressing tumors and metastases. https://app.cochat.ai/papers/10.1073/pnas.97.3.1206
- The paper
- Yang, M., Baranov, E., Jiang, P., Sun, F.-X., Li, X.-M., Li, L., Hasegawa, S., Bouvet, M., Al-Tuwaijri, M., Chishima, T., Shimada, H., Moossa, A. R., Penman, S., & Hoffman, R. M. (2000). Whole-body optical imaging of green fluorescent protein-expressing tumors and metastases. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.97.3.1206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.