The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Rapid Mechanotransduction in Situ at the Luminal Cell Surface of Vascular Endothelium and Its Caveolae
Open accessAbstract
The vascular endothelium is uniquely positioned between the blood and tissue compartments to receive directly the fluid forces generated by the blood flowing through the vasculature. These forces invoke specific responses within endothelial cells and serve to modulate their intrinsic structure and function. The mechanisms by which hemodynamic forces are detected and converted by endothelia into a sequence of biological and even pathological responses are presently unknown. By purifying and subfractionating the luminal endothelial cell plasma membrane from tissue, we show, for the first time, that not only does mechanotransduction occur at the endothelial cell surface directly exposed to vascular flow in vivo but also increased flow in situ induces rapid tyrosine phosphorylation of luminal endothelial cell surface proteins located primarily in the plasmalemmal invaginations called caveolae. Increased flow induces the translocation of signaling molecules primarily to caveolae, ultimately activating the Ras-Raf-mitogen-activated protein kinase pathway. This signaling appears to require intact caveolae. Filipin-induced disassembly of caveolae inhibits both proximal signaling events at the cell surface and downstream activation of the mitogen-activated protein kinase pathway. With the molecular machinery required for mediating rapid flow-induced responses as seen in endothelium, caveolae may be flow-sensing organelles converting mechanical stimuli into chemical signals transmitted into the cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Dissecting the Interaction between Nitric Oxide Synthase (NOS) and Caveolin
Garcı́a-Cardeña, G., Martasek, P., Masters, B. S. S., Skidd, P. M., Couet, J., Li, S., Lisanti, M. P., & Sessa, W. C. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.41.25437 · Cited by 821
Cited by
Cellular mechanotransduction: putting all the pieces together again
Ingber, D. E. (2006) · The FASEB Journal · doi:10.1096/fj.05-5424rev · Cited by 1,627
Caveolae as plasma membrane sensors, protectors and organizers
Parton, R. G., & del Pozo, M. A. (2013) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3512 · Cited by 924
Ion Channels and Their Functional Role in Vascular Endothelium
Nilius, B., & Droogmans, G. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1415 · Cited by 868
Membrane microdomains and caveolae
Kurzchalia, T. V., & Partan, R. G. (1999) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(99)80061-1 · Cited by 579
Mechanotransduction: All Signals Point to Cytoskeleton, Matrix, and Integrins
Alenghat, F. J., & Ingber, D. E. (2002) · Science's STKE · doi:10.1126/stke.2002.119.pe6 · Cited by 494
Metadata
- Authors
- Rizzo, V., Sung, A., Oh, P., & Schnitzer, J. E.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1998-10
- Volume
- 273
- Issue
- 41
- Pages
- 26323-26329
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2087896363
- Cited by
- 186
- References
- 2
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.