The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
The Q Exactive HF, a Benchtop Mass Spectrometer with a Pre-filter, High-performance Quadrupole and an Ultra-high-field Orbitrap Analyzer
Open accessAbstract
The quadrupole Orbitrap mass spectrometer (Q Exactive) made a powerful proteomics instrument available in a benchtop format. It significantly boosted the number of proteins analyzable per hour and has now evolved into a proteomics analysis workhorse for many laboratories. Here we describe the Q Exactive Plus and Q Exactive HF mass spectrometers, which feature several innovations in comparison to the original Q Exactive instrument. A low-resolution pre-filter has been implemented within the injection flatapole, preventing unwanted ions from entering deep into the system, and thereby increasing its robustness. A new segmented quadrupole, with higher fidelity of isolation efficiency over a wide range of isolation windows, provides an almost 2-fold improvement of transmission at narrow isolation widths. Additionally, the Q Exactive HF has a compact Orbitrap analyzer, leading to higher field strength and almost doubling the resolution at the same transient times. With its very fast isolation and fragmentation capabilities, the instrument achieves overall cycle times of 1 s for a top 15 to 20 higher energy collisional dissociation method. We demonstrate the identification of 5000 proteins in standard 90-min gradients of tryptic digests of mammalian cell lysate, an increase of over 40% for detected peptides and over 20% for detected proteins. Additionally, we tested the instrument on peptide phosphorylation enriched samples, for which an improvement of up to 60% class I sites was observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Self-citationggplot2: Elegant Graphics for Data Analysis
Wickham, H. (2009) · doi:10.1007/978-0-387-98141-3 · Cited by 14,447
R: A Language for Data Analysis and Graphics
Ihaka, R., & Gentleman, R. (1996) · Journal of Computational and Graphical Statistics · doi:10.1080/10618600.1996.10474713 · Cited by 11,220
Universal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
Self-citationMass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Self-citationAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Self-citationGillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Design and Analysis of Experiments
Grice, J. V., & Montgomery, D. C. (2000) · Technometrics · doi:10.2307/1271458 · Cited by 2,654
Rappsilber, J., Ishihama, Y., & Mann, M. (2003) · Analytical Chemistry · doi:10.1021/ac026117i · Cited by 2,644
Self-citationThompson, A., Schäfer, J., Kuhn, K., Kienle, S., Schwarz, J., Schmidt, G., Neumann, T., & Hamon, C. (2003) · Analytical Chemistry · doi:10.1021/ac0262560 · Cited by 2,378
Design and Analysis of Experiments, 5th Ed.
Copeland, K. A. F. (2001) · Journal of Quality Technology · doi:10.1080/00224065.2001.11980088 · Cited by 1,475
Interpretation of Shotgun Proteomic Data
Nesvizhskii, A. I., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500012-mcp200 · Cited by 1,025
Deep proteome and transcriptome mapping of a human cancer cell line
Nagaraj, N., Wisniewski, J. R., Geiger, T., Cox, J., Kircher, M., Kelso, J., Pääbo, S., & Mann, M. (2011) · Molecular Systems Biology · doi:10.1038/msb.2011.81 · Cited by 979
Self-citationMichalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832 · cited 3×
“Up to the Orbitrap Velos and Elite members of this family of instruments, the precursor selection (and usually the fragmentation) occurred in the linear ion trap (13), but a few years ago an instrument based on a quadrupole front end—the Q Exactive mass spectrometer—was developed (14).”
BackgroundMethodInfluentialSelf-citationThe quantitative proteome of a human cell line
Beck, M., Schmidt, A., Malmstroem, J., Claassen, M., Ori, A., Szymborska, A., Herzog, F., Rinner, O., Ellenberg, J., & Aebersold, R. (2011) · Molecular Systems Biology · doi:10.1038/msb.2011.82 · Cited by 816
Geiger, T., Wehner, A., Schaab, C., Cox, J., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014050 · Cited by 797
Self-citationA “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards
Wiśniewski, J. R., Hein, M. Y., Cox, J., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.037309 · Cited by 690
Self-citationMichalski, A., Cox, J., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101060v · Cited by 685
Self-citationZubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Self-citationTargeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Self-citationNagaraj, N., Alexander Kulak, N., Cox, J., Neuhauser, N., Mayr, K., Hoerning, O., Vorm, O., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.013722 · Cited by 392
Self-citationMichalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Self-citationDeep and Highly Sensitive Proteome Coverage by LC-MS/MS Without Prefractionation
Thakur, S. S., Geiger, T., Chatterjee, B., Bandilla, P., Fröhlich, F., Cox, J., & Mann, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003699 · Cited by 337
Self-citationKelstrup, C. D., Young, C., Lavallee, R., Nielsen, M. L., & Olsen, J. V. (2012) · Journal of Proteome Research · doi:10.1021/pr3000249 · Cited by 281
DMSO enhances electrospray response, boosting sensitivity of proteomic experiments
Hahne, H., Pachl, F., Ruprecht, B., Maier, S. K., Klaeger, S., Helm, D., Médard, G., Wilm, M., Lemeer, S., & Kuster, B. (2013) · Nature Methods · doi:10.1038/nmeth.2610 · Cited by 234
Performance evaluation of a high-field Orbitrap mass analyzer
Makarov, A., Denisov, E., & Lange, O. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.01.005 · Cited by 188
Self-citationBelov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Self-citationTrends in ultrasensitive proteomics
Altelaar, M. A. F., & Heck, A. J. R. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2011.12.011 · Cited by 148
Köcher, T., Swart, R., & Mechtler, K. (2011) · Analytical Chemistry · doi:10.1021/ac103243t · Cited by 143
Savitski, M. M., Sweetman, G. M. A., Askenazi, M., Marto, J. A., Lang, M., Zinn, N., & Bantscheff, M. (2011) · Analytical Chemistry · doi:10.1021/ac201760x · Cited by 110
Enhanced Fourier transform for Orbitrap mass spectrometry
Lange, O., Damoc, E., Wieghaus, A., & Makarov, A. (2014) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.05.019 · Cited by 99
Self-citationZhou, F., Lu, Y., Ficarro, S. B., Webber, J. T., & Marto, J. A. (2012) · Analytical Chemistry · doi:10.1021/ac2031404 · Cited by 68
Pichler, P., Mazanek, M., Dusberger, F., Weilnböck, L., Huber, C. G., Stingl, C., Luider, T. M., Straube, W. L., Köcher, T., & Mechtler, K. (2012) · Journal of Proteome Research · doi:10.1021/pr300163u · Cited by 62
Scheltema, R. A., & Mann, M. (2012) · Journal of Proteome Research · doi:10.1021/pr201219e · Cited by 61
Self-citationRandall, S. M., Cardasis, H. L., & Muddiman, D. C. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0693-y · Cited by 35
Cited by
Plasma Proteome Profiling to Assess Human Health and Disease
Geyer, P. E., Kulak, N. A., Pichler, G., Holdt, L. M., Teupser, D., & Mann, M. (2016) · Cell Systems · doi:10.1016/j.cels.2016.02.015 · Cited by 734
“Ultra-High-Pressure LC and MS Samples were measured using LC-MS instrumentation consisting of an EASYnLC 1000 ultra-high-pressure system (Thermo Fisher Scientific) coupled via a nano-electrospray ion source (Thermo Fisher Scientific) to a Q Exactive HF Orbitrap (Thermo Fisher Scientific) (Scheltema et al., 2014).”
MethodInfluentialSelf-citationZubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Self-citationGlobal, quantitative and dynamic mapping of protein subcellular localization
Itzhak, D. N., Tyanova, S., Cox, J., & Borner, G. H. (2016) · eLife · doi:10.7554/elife.16950 · Cited by 649
Metabolic modulation of tumours with engineered bacteria for immunotherapy
Canale, F. P., Basso, C., Antonini, G., Perotti, M., Li, N., Sokolovska, A., Neumann, J., James, M. J., Geiger, S., Jin, W., et al. (2021) · Nature · doi:10.1038/s41586-021-04003-2 · Cited by 619
Genetic diagnosis of Mendelian disorders via RNA sequencing
Kremer, L. S., Bader, D. M., Mertes, C., Kopajtich, R., Pichler, G., Iuso, A., Haack, T. B., Graf, E., Schwarzmayr, T., Terrile, C., et al. (2017) · Nature Communications · doi:10.1038/ncomms15824 · Cited by 590
Metadata
- Authors
- Scheltema, R. A., Hauschild, J.-P., Lange, O., Hornburg, D., Denisov, E., Damoc, E., Kuehn, A., Makarov, A., & Mann, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 13
- Issue
- 12
- Pages
- 3698-3708
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2152095891
- Cited by
- 323
- References
- 36
- FWCI
- 15.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.