Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

The Impact II, a Very High-Resolution Quadrupole Time-of-Flight Instrument (QTOF) for Deep Shotgun Proteomics *

Open access
Beck, Scarlet, Michalski, Annette, Raether, Oliver, Lubeck, Markus, Kaspar, Stephanie, Goedecke, Niels, Baessmann, Carsten, Hornburg, Daniel, Meier, Florian, Paron, Igor, Kulak, Nils A., Cox, Juergen, Mann, Matthias·2015·Molecular & Cellular Proteomics

Abstract

Hybrid quadrupole time-of-flight (QTOF) mass spectrometry is one of the two major principles used in proteomics. Although based on simple fundamentals, it has over the last decades greatly evolved in terms of achievable resolution, mass accuracy, and dynamic range. The Bruker impact platform of QTOF instruments takes advantage of these developments and here we develop and evaluate the impact II for shotgun proteomics applications. Adaption of our heated liquid chromatography system achieved very narrow peptide elution peaks. The impact II is equipped with a new collision cell with both axial and radial ion ejection, more than doubling ion extraction at high tandem MS frequencies. The new reflectron and detector improve resolving power compared with the previous model up to 80%, i.e. to 40,000 at m/z 1222. We analyzed the ion current from the inlet capillary and found very high transmission (>80%) up to the collision cell. Simulation and measurement indicated 60% transfer into the flight tube. We adapted MaxQuant for QTOF data, improving absolute average mass deviations to better than 1.45 ppm. More than 4800 proteins can be identified in a single run of HeLa digest in a 90 min gradient. The workflow achieved high technical reproducibility (R2 > 0.99) and accurate fold change determination in spike-in experiments in complex mixtures. Using label-free quantification we rapidly quantified haploid against diploid yeast and characterized overall proteome differences in mouse cell lines originating from different tissues. Finally, after high pH reversed-phase fractionation we identified 9515 proteins in a triplicate measurement of HeLa peptide mixture and 11,257 proteins in single measurements of cerebellum-the highest proteome coverage reported with a QTOF instrument so far.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.m114.047407

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Research works printed but not linked: 39

  1. Karas, 1988, Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons, Anal. Chem, 60, 2299, 10.1021/ac00171a028 · DOI · Paper page
  2. Cravatt, 2007, The biological impact of mass-spectrometry-based proteomics, Nature, 450, 991, 10.1038/nature06525 · DOI · Paper page
  3. Altelaar, 2013, Next-generation proteomics: towards an integrative view of proteome dynamics, Nat. Rev. Genet, 14, 35, 10.1038/nrg3356 · DOI · Paper page
  4. Richards, 2014, Proteome sequencing goes deep, Curr. Opin. Chem. Biol, 24C, 11
  5. Domon, 2006, Challenges and opportunities in proteomics data analysis, Mol. Cell. Proteomics, 5, 1921, 10.1074/mcp.R600012-MCP200 · DOI
  6. Makarov, 2000, Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis, Anal. Chem, 72, 1156, 10.1021/ac991131p · DOI · Paper page
  7. Zubarev, 2013, Orbitrap mass spectrometry, Anal. Chem, 85, 5288, 10.1021/ac4001223 · DOI · Paper page
  8. Scheltema, 2014, The Q exactive HF, a benchtop mass spectrometer with a pre-filter, high-performance quadrupole and an ultra-high-field Orbitrap analyzer, Mol. Cell. Proteomics, 13, 3698, 10.1074/mcp.M114.043489 · DOI · Paper page
  9. Kelstrup, 2014, Rapid and deep proteomes by faster sequencing on a benchtop quadrupole ultra-high-field Orbitrap mass spectrometer, J. Proteome Res, 13, 12, 6187, 10.1021/pr500985w · DOI · Paper page
  10. Zhou, 2011, Proteomic reactors and their applications in biology, FEBS J, 278, 3796, 10.1111/j.1742-4658.2011.08292.x · DOI · Paper page
  11. Kocher, 2011, Ultra-high-pressure RPLC hyphenated to an LTQ-Orbitrap Velos reveals a linear relation between peak capacity and number of identified peptides, Anal. Chem, 83, 2699, 10.1021/ac103243t · DOI
  12. Cox, 2011, Quantitative, high-resolution proteomics for data-driven systems biology, Annu. Rev. Biochem, 80, 273, 10.1146/annurev-biochem-061308-093216 · DOI · Paper page
  13. Nagaraj, 2012, System-wide perturbation analysis with nearly complete coverage of the yeast proteome by single-shot ultra HPLC runs on a bench top Orbitrap, Mol. Cell. Proteomics, 11, 10.1074/mcp.M111.013722 · DOI · Paper page
  14. Savitski, 2006, ModifiComb, a new proteomic tool for mapping substoichiometric post-translational modifications, finding novel types of modifications, and fingerprinting complex protein mixtures, Mol. Cell. Proteomics, 5, 935, 10.1074/mcp.T500034-MCP200 · DOI · Paper page
  15. Morris, 1996, High sensitivity collisionally-activated decomposition tandem mass spectrometry on a novel quadrupole/orthogonal-acceleration time-of-flight mass spectrometer, Rapid Commun. Mass Spectr, 10, 889, 10.1002/(SICI)1097-0231(19960610)10:8<889::AID-RCM615>3.0.CO;2-F · DOI · Paper page
  16. Silva, 2006, Simultaneous qualitative and quantitative analysis of the Escherichia coli proteome: a sweet tale, Mol. Cell. Proteomics, 5, 589, 10.1074/mcp.M500321-MCP200 · DOI · Paper page
  17. Distler, 2014, Drift time-specific collision energies enable deep-coverage data-independent acquisition proteomics, Nat. Methods, 11, 167, 10.1038/nmeth.2767 · DOI · Paper page
  18. Helm, 2014, Ion mobility tandem mass spectrometry enhances performance of bottom-up proteomics, Mol. Cell. Proteomics, 13, 3709, 10.1074/mcp.M114.041038 · DOI
  19. Hornburg, 2014, Deep proteomic evaluation of primary and cell line motoneuron disease models delineates major differences in neuronal characteristics, Mol. Cell. Proteomics, 13, 3410, 10.1074/mcp.M113.037291 · DOI
  20. Rappsilber, 2007, Protocol for micro-purification, enrichment, prefractionation, and storage of peptides for proteomics using StageTips, Nature Protoc, 2, 1896, 10.1038/nprot.2007.261 · DOI · Paper page
  21. Wang, 2005, Development and evaluation of a micro- and nanoscale proteomic sample preparation method, J. Proteome Res, 4, 2397, 10.1021/pr050160f · DOI · Paper page
  22. Dwivedi, 2008, Practical implementation of 2D HPLC scheme with accurate peptide retention prediction in both dimensions for high-throughput bottom-up proteomics, Anal. Chem, 80, 7036, 10.1021/ac800984n · DOI · Paper page
  23. Whitehouse, 1985, Electrospray interface for liquid chromatographs and mass spectrometers, Anal. Chem, 57, 675, 10.1021/ac00280a023 · DOI · Paper page
  24. Franzen, 1998, Method and device for transport of ions in gas through a capillary, Google Patents
  25. Ishihama, 2002, Microcolumns with self-assembled particle frits for proteomics, J. Chromatogr. A, 979, 233, 10.1016/S0021-9673(02)01402-4 · DOI · Paper page
  26. Ayoub, 2013, Correct primary structure assessment and extensive glyco-profiling of cetuximab by a combination of intact, middle-up, middle-down, and bottom-up ESI and MALDI mass spectrometry techniques, mAbs, 5, 699, 10.4161/mabs.25423 · DOI · Paper page
  27. Tsybin, 2011, Structural analysis of intact monoclonal antibodies by electron transfer dissociation mass spectrometry, Anal. Chem, 83, 8919, 10.1021/ac201293m · DOI
  28. Cox, 2011, Andromeda: a peptide search engine integrated into the MaxQuant environment, J. Proteome Res, 10, 1794, 10.1021/pr101065j · DOI · Paper page
  29. 2014, R Core Team A language and environment for statistical computing, R Foundation for Statistical Computing, Vienna, Austria
  30. Cox, 2012, 1D and 2D annotation enrichment: a statistical method integrating quantitative proteomics with complementary high-throughput data, BMC Bioinformatics, 13, S12, 10.1186/1471-2105-13-S16-S12 · DOI · Paper page
  31. Shaffer, 1998, An ion funnel interface for improved ion focusing and sensitivity using electrospray ionization mass spectrometry, Anal. Chem, 70, 4111, 10.1021/ac9802170 · DOI · Paper page
  32. Gerlich, 1992, Inhomogeneous RF fields a versatile tool for the study of processes with slow ions, John Wiley & Sons, Inc, Hoboken, NJ, U.S.A., 13
  33. Steen, 2001, Detection of tyrosine phosphorylated peptides by precursor ion scanning quadrupole TOF mass spectrometry in positive ion mode, Anal. Chem, 73, 1440, 10.1021/ac001318c · doi:10.1021/ac001318c
  34. Räther, 2005, High resolution detection for time-of-flight mass spectrometers, US6870156 B2 patent
  35. Cox, 2008, How much peptide sequence information is contained in ion trap tandem mass spectra?, J. Am. Soc. Mass Spectr, 19, 1813, 10.1016/j.jasms.2008.07.024 · DOI
  36. Cox, 2011, Software lock mass by two-dimensional minimization of peptide mass errors, J. Am. Soc. Mass Spectr, 22, 1373, 10.1007/s13361-011-0142-8 · DOI
  37. Wang, 2011, Reversed-phase chromatography with multiple fraction concatenation strategy for proteome profiling of human MCF10A cells, Proteomics, 11, 2019, 10.1002/pmic.201000722 · DOI · Paper page
  38. Apanovitch, 1998, Sst2 is a GTPase-activating protein for Gpa1: purification and characterization of a cognate RGS-Galpha protein pair in yeast, Biochemistry, 37, 4815, 10.1021/bi9729965 · doi:10.1021/bi9729965
  39. Suzuki, 2004, Identification of region-specific transcription factor genes in the adult mouse brain by medium-scale real-time RT-PCR, FEBS Letters, 573, 214, 10.1016/j.febslet.2004.07.068 · DOI

Cited by

See all 175

Metadata

Authors
Beck, S., Michalski, A., Raether, O., Lubeck, M., Kaspar, S., Goedecke, N., Baessmann, C., Hornburg, D., Meier, F., Paron, I., Kulak, N. A., Cox, J., & Mann, M.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2015-07
Volume
14
Issue
7
Pages
2014-2029
ISSN
1535-9476 (ISSN-L)
OpenAlex
W2113550007
Cited by
175
References
16
FWCI
9.62
Type
journal article
Language
en
Open access
hybrid
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Impact II, a Very High-Resolution Quadrupole Time-of-Flight Instrument (QTOF) for Deep Shotgun Proteomics *. https://app.cochat.ai/papers/10.1074/mcp.m114.047407
The paper
Beck, S., Michalski, A., Raether, O., Lubeck, M., Kaspar, S., Goedecke, N., Baessmann, C., Hornburg, D., Meier, F., Paron, I., Kulak, N. A., Cox, J., & Mann, M. (2015). The Impact II, a Very High-Resolution Quadrupole Time-of-Flight Instrument (QTOF) for Deep Shotgun Proteomics *. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m114.047407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.