CoChat

Automated Identification and Quantification of Protein Phosphorylation Sites by LC/MS on a Hybrid Triple Quadrupole Linear Ion Trap Mass Spectrometer

Open access
Williamson, Brian L., Marchese, Jason, Morrice, Nicholas A. · 2006 · Molecular & Cellular Proteomics
Cited by 108

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Complete phosphorylation mapping of protein kinases was successfully undertaken using an automated LC/MS/MS approach. This method uses the direct combination of triple quadrupole and ion trapping capabilities in a hybrid triple quadrupole linear ion trap to selectively identify and sequence phosphorylated peptides. In particular, the use of a precursor ion scan of m/z -79 in negative ion mode followed by an ion trap high resolution scan (an enhanced resolution scan) and a high sensitivity MS/MS scan (enhanced product ion scan) in positive mode is a very effective method for identifying phosphorylation sites in proteins at low femtomole levels. Coupling of this methodology with a stable isotope N-terminal labeling strategy using iTRAQtrade mark reagents enabled phosphorylation mapping and relative protein phosphorylation levels to be determined between the active and inactive forms of the protein kinase MAPKAPK-1 in the same LC/MS run.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.m500210-mcp200

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Williamson, B. L., Marchese, J., & Morrice, N. A.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2006-02
Volume
5
Issue
2
Pages
337-346
ISSN
1535-9476 (ISSN-L)
OpenAlex
W2142227713
Cited by
108
References
2
FWCI
5.93
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.