CoChat

A Method for Automatically Interpreting Mass Spectra of 18O-Labeled Isotopic Clusters

Open access
Mason, Christopher J., Therneau, Terry M., Eckel-Passow, Jeanette E., Johnson, Kenneth L., Oberg, Ann L., Olson, Janet E., Nair, K. Sreekumaran, Muddiman, David C., Bergen, H. Robert · 2007 · Molecular & Cellular Proteomics
Cited by 61

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

16O/18O labeling is one differential proteomics technology among many that promises diagnostic and prognostic biomarkers of disease. Although the incorporation of 18O in the C-terminal carboxyl group during endoproteinase digestion in the presence of H2 18O makes the process of labeling facile, the ease and effectiveness of label incorporation have in some regards been outweighed by the difficulties in interpreting the resulting spectra. Complex isotope patterns result from the composition of unlabeled (18O(0)), singly labeled (18O(1)), and doubly labeled species (18O(2)) as well as contributions from the naturally occurring isotopes (e.g. 13C and 15N). Moreover because labeling is enzymatic, the number of 18O atoms incorporated can vary from peptide to peptide. Finally it is difficult to distinguish highly up-regulated from highly down-regulated or C-terminal peptides. We have developed an algorithm entitled regression analysis applied to mass spectrometry (RAAMS) that automatically, rapidly, and confidently interprets spectra of 18O-labeled peptides without requiring chemical composition information derived from product ion spectra. The algorithm is able to measure the effective 18O incorporation rate due to variable enzyme substrate specificity of the pseudosubstrate during the isotope exchange reaction and corrects for the 18O(0) abundance that remains in the labeled sample when using a two-step digestion/labeling procedure. We have also incorporated a method for distinguishing pure 18O(0) from pure 18O(2) peptides utilizing impure H2 18O. The algorithm operates on centroided peak lists and is therefore very fast: nine chromatograms of, on average, 1,168 spectra and containing, on average, 6,761 isotopic clusters were interpreted in, on average, 45 s per chromatogram. RAAMS is fast enough (average, 38 ms/spectrum) to allow the possibility of performing information-dependent MS/MS on a chromatographic time scale on species exceeding predetermined ratio thresholds. We describe in detail the operation of the algorithm and demonstrate its use on datasets with known and unknown ratios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.m600148-mcp200

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 61

Metadata

Authors
Mason, C. J., Therneau, T. M., Eckel-Passow, J. E., Johnson, K. L., Oberg, A. L., Olson, J. E., Nair, K. S., Muddiman, D. C., & Bergen, H. R.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2007-02
Volume
6
Issue
2
Pages
305-318
ISSN
1535-9476 (ISSN-L)
OpenAlex
W2122545105
Cited by
61
References
4
FWCI
3.11
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.