The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Automated reduction and interpretation of
Abstract
Here a fully automated computer algorithm is applied to complex mass spectra of peptides and proteins. This method uses a subtractive peak finding routine to locate possible isotopic clusters in the spectrum, subjecting these to a combination of the previous Fourier transform/Patterson method for primary charge determination and the method for least-squares fitting to a theoretically derived isotopic abundance distribution for m/z determination of the most abundant isotopic peak, and the statistical reliability of this determination. If a predicted protein sequence is available, each such m/z value is checked for assignment as a sequence fragment. A new signal-to-noise calculation procedure has been devised for accurate determination of baseline and noise width for spectra with high peak density. In 2 h, the program identified 824 isotopic clusters representing 581 mass values in the spectrum of a GluC digest of a 191 kDa protein; this is >50% more than the number of mass values found by the extremely tedious operator-applied methodology used previously. The program should be generally applicable to classes of large molecules, including DNA and polymers. Thorough high resolution analysis of spectra by Horn (THRASH) is proposed as the program's verb.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Thorough High-Resolution Analysis of Spectra by Horn (THRASH) was the first software to automate the deconvolution of high-resolution mass spectra and is still widely used [124].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [124]
In the citing paper
“Currently, the software incorporates various deconvolution algorithms including MS-Deconv,17 TopFD,14 eTHRASH,19 pParseTD,15 and ProMex26 for both MS and MS/MS deconvolution.”
From MASH Explorer: A Universal Software Environment for Top-Down Proteomics (2020) · cites this paper as [19]
Citations
Cites
The Complete Genome Sequence of Escherichia coli K-12
Blattner, F. R., Plunkett, G., Bloch, C. A., Perna, N. T., Burland, V., Riley, M., Collado-Vides, J., Glasner, J. D., Rode, C. K., Mayhew, G. F., et al. (1997) · Science · doi:10.1126/science.277.5331.1453 · Cited by 7,452
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationElectrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Self-citationTailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
Self-citationInterpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Research works printed but not linked: 1
- Drader, J. J.; Shi, S. D.H.; Freitas, M. A.; Hendrickson, C. L.; Marshall, A. G. Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics; Orlando, FL, 31 May–4 June 1998; p. 499, http://magnet.fsu.edu/~midas.
Cited by
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665
OpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
Metadata
- Authors
- Horn, D. M., Zubarev, R. A., & McLafferty, F. W.
- Affiliations
- Cornell University (US)
- ORCID
- Zubarev, Roman A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-04-01
- Volume
- 11
- Issue
- 4
- Pages
- 320-332
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1519955500
- Cited by
- 507
- References
- 47
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 17 · 2023: 13 · 2022: 9 · 2021: 9 · 2020: 21 · 2019: 19 · 2018: 16 · 2017: 20 · 2016: 21 · 2015: 20 · 2014: 22 · 2013: 17 · 2012: 21
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National High Magnetic Field Laboratory
- National Institute of General Medical Sciences (GM 16609)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- least squares fitting, peptide mass mapping, high-resolution mass spectrometry
- MeSH terms
- Algorithms, Data Interpretation, Statistical, Gas Chromatography-Mass Spectrometry, Peptides, Proteins, Software, Mass Spectrometry, Chi-Square Distribution, Least-Squares Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated reduction and interpretation of. https://app.cochat.ai/papers/10.1016/s1044-0305(99)00157-9
- The paper
- Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000). Automated reduction and interpretation of. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(99)00157-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.