Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Automated reduction and interpretation of

Horn, David M., Zubarev, Roman A., McLafferty, Fred W. · 2000 · Journal of the American Society for Mass Spectrometry

Abstract

Here a fully automated computer algorithm is applied to complex mass spectra of peptides and proteins. This method uses a subtractive peak finding routine to locate possible isotopic clusters in the spectrum, subjecting these to a combination of the previous Fourier transform/Patterson method for primary charge determination and the method for least-squares fitting to a theoretically derived isotopic abundance distribution for m/z determination of the most abundant isotopic peak, and the statistical reliability of this determination. If a predicted protein sequence is available, each such m/z value is checked for assignment as a sequence fragment. A new signal-to-noise calculation procedure has been devised for accurate determination of baseline and noise width for spectra with high peak density. In 2 h, the program identified 824 isotopic clusters representing 581 mass values in the spectrum of a GluC digest of a 191 kDa protein; this is >50% more than the number of mass values found by the extremely tedious operator-applied methodology used previously. The program should be generally applicable to classes of large molecules, including DNA and polymers. Thorough high resolution analysis of spectra by Horn (THRASH) is proposed as the program's verb.

Overview

Integrity signals

Registry

Crossref · 10.1016/s1044-0305(99)00157-9

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 47 references

Research works printed but not linked: 1

  1. Drader, J. J.; Shi, S. D.H.; Freitas, M. A.; Hendrickson, C. L.; Marshall, A. G. Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics; Orlando, FL, 31 May–4 June 1998; p. 499, http://magnet.fsu.edu/~midas.

Cited by

See all 507

Metadata

Authors
Horn, D. M., Zubarev, R. A., & McLafferty, F. W.
Affiliations
Cornell University (US)
Venue
Journal of the American Society for Mass Spectrometry
Published
2000-04-01
Volume
11
Issue
4
Pages
320-332
ISSN
1044-0305 (ISSN-L)
OpenAlex
W1519955500
Cited by
507
References
47
Citations by year
2026: 11 · 2025: 9 · 2024: 17 · 2023: 13 · 2022: 9 · 2021: 9 · 2020: 21 · 2019: 19 · 2018: 16 · 2017: 20 · 2016: 21 · 2015: 20 · 2014: 22 · 2013: 17 · 2012: 21
FWCI
10.08
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the American Society for Mass Spectrometry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National High Magnetic Field Laboratory
  • National Institute of General Medical Sciences (GM 16609)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
least squares fitting, peptide mass mapping, high-resolution mass spectrometry
MeSH terms
Algorithms, Data Interpretation, Statistical, Gas Chromatography-Mass Spectrometry, Peptides, Proteins, Software, Mass Spectrometry, Chi-Square Distribution, Least-Squares Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated reduction and interpretation of. https://app.cochat.ai/papers/10.1016/s1044-0305(99)00157-9
The paper
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000). Automated reduction and interpretation of. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(99)00157-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.