The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Reproducibility, Specificity and Accuracy of Relative Quantification Using Spectral Library-based Data-independent Acquisition
Open accessAbstract
Currently data-dependent acquisition (DDA) is the method of choice for mass spectrometry-based proteomics discovery experiments, but data-independent acquisition (DIA) is steadily becoming more important. One of the most important requirements to perform a DIA analysis is the availability of suitable spectral libraries for peptide identification and quantification. Several studies were performed addressing the evaluation of spectral library performance for protein identification in DIA measurements. But so far only few experiments estimate the effect of these libraries on the quantitative level.In this work we created a gold standard spike-in sample set with known contents and ratios of proteins in a complex protein matrix that allowed a detailed comparison of DIA quantification data obtained with different spectral library approaches. We used in-house generated sample-specific spectral libraries created using varying sample preparation approaches and repeated DDA measurement. In addition, two different search engines were tested for protein identification from DDA data and subsequent library generation. In total, eight different spectral libraries were generated, and the quantification results compared with a library free method, as well as a default DDA analysis. Not only the number of identifications on peptide and protein level in the spectral libraries and the corresponding DIA analysis results was inspected, but also the number of expected and identified differentially abundant protein groups and their ratios.We found, that while libraries of prefractionated samples were generally larger, there was no significant increase in DIA identifications compared with repetitive non-fractionated measurements. Furthermore, we show that the accuracy of the quantification is strongly dependent on the applied spectral library and whether the quantification is based on peptide or protein level. Overall, the reproducibility and accuracy of DIA quantification is superior to DDA in all applied approaches.Data has been deposited to the ProteomeXchange repository with identifiers PXD012986, PXD012987, PXD012988 and PXD014956.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Käll, L., Canterbury, J. D., Weston, J., Noble, W. S., & MacCoss, M. J. (2007) · Nature Methods · doi:10.1038/nmeth1113 · Cited by 2,424
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302 · cited 2×
“In SRM a predefined set of up to 100 precursors is chosen for fragmentation before acquisition, resulting in highly accurate quantification even at low abundance at the cost of the depth of the analyzed proteome (5, 13).”
Bruderer, R., Bernhardt, O. M., Gandhi, T., Miladinović, S. M., Cheng, L.-Y., Messner, S., Ehrenberger, T., Zanotelli, V., Butscheid, Y., Escher, C., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.044305 · Cited by 1,238
A “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards
Wiśniewski, J. R., Hein, M. Y., Cox, J., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.037309 · Cited by 690
Michalski, A., Cox, J., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101060v · Cited by 685
Tabb, D. L., Vega-Montoto, L., Rudnick, P. A., Variyath, A. M., Ham, A.-J. L., Bunk, D. M., Kilpatrick, L. E., Billheimer, D. D., Blackman, R. K., Cardasis, H. L., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr9006365 · Cited by 551
A repository of assays to quantify 10,000 human proteins by SWATH-MS
Rosenberger, G., Koh, C. C., Guo, T., Röst, H. L., Kouvonen, P., Collins, B. C., Heusel, M., Liu, Y., Caron, E., Vichalkovski, A., et al. (2014) · Scientific Data · doi:10.1038/sdata.2014.31 · Cited by 413
A multicenter study benchmarks software tools for label-free proteome quantification
Navarro, P., Kuharev, J., Gillet, L. C., Bernhardt, O. M., MacLean, B., Röst, H. L., Tate, S. A., Tsou, C.-C., Reiter, L., Distler, U., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3685 · Cited by 346
Reiter, L., Claassen, M., Schrimpf, S. P., Jovanovic, M., Schmidt, A., Buhmann, J. M., Hengartner, M. O., & Aebersold, R. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900317-mcp200 · Cited by 312 · cited 2×
“The analysis followed the basic tutorial settings of OpenSWATH using Mascot search re-sults, iProphet (47) for the combination of results, Mayu (48) for the FDR estimation and spectraST (49) for the actual library generation.”
Cited by
Integrated Omics of Metastatic Colorectal Cancer
Li, C., Sun, Y.-D., Yu, G.-Y., Cui, J.-R., Lou, Z., Zhang, H., Huang, Y., Bai, C.-G., Deng, L.-L., Liu, P., et al. (2020) · Cancer Cell · doi:10.1016/j.ccell.2020.08.002 · Cited by 297
Analysis of DIA proteomics data using MSFragger-DIA and FragPipe computational platform
Yu, F., Teo, G. C., Kong, A. T., Fröhlich, K., Li, G. X., Demichev, V., & Nesvizhskii, A. I. (2023) · Nature Communications · doi:10.1038/s41467-023-39869-5 · Cited by 292
Quantitative Mass Spectrometry-Based Proteomics: An Overview
Rozanova, S., Barkovits, K., Nikolov, M., Schmidt, C., Urlaub, H., & Marcus, K. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-1024-4_8 · Cited by 275
Self-citation(2023) · doi:10.1016/j.redox.2023.102908 · Cited by 39
Metadata
- Authors
- Barkovits, K., Pacharra, S., Pfeiffer, K., Steinbach, S., Eisenacher, M., Marcus, K., & Uszkoreit, J.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 19
- Issue
- 1
- Pages
- 181-197
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2984906251
- Cited by
- 188
- References
- 10
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility, Specificity and Accuracy of Relative Quantification Using Spectral Library-based Data-independent Acquisition. https://app.cochat.ai/papers/10.1074/mcp.ra119.001714
- The paper
- Barkovits, K., Pacharra, S., Pfeiffer, K., Steinbach, S., Eisenacher, M., Marcus, K., & Uszkoreit, J. (2020). Reproducibility, Specificity and Accuracy of Relative Quantification Using Spectral Library-based Data-independent Acquisition. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.ra119.001714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.