Efficient Fractionation and Improved Protein Identification by Peptide OFFGEL Electrophoresis
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The sample fractionation steps conducted prior to mass detection are critically important for the comprehensive analysis of complex protein mixtures. This paper illustrates the effectiveness of OFFGEL electrophoresis with the Agilent 3100 OFFGEL Fractionator for the fractionation of peptides. An Escherichia coli tryptic digest was separated in 24 fractions, and peptides were identified by reversed-phase liquid chromatography on a microfluidic device with mass spectrometric detection. About 90% of the identified individual peptides were found in only one or two fractions. The distribution of the calculated isoelectric points for the peptides identified in each fraction was especially narrow in the acidic pH range. Standard deviations approached the size of the pH segment covered by the respective fraction. The experimental peptide isoelectric point measured by OFFGEL electrophoresis was used as an additional filter for validation of peptide identifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819
Bjellqvist, B., Hughes, G. J., Pasquali, C., Paquet, N., Ravier, F., Sanchez, J., Frutiger, S., & Hochstrasser, D. (1993) · ELECTROPHORESIS · doi:10.1002/elps.11501401163 · Cited by 1,014
Potential for False Positive Identifications from Large Databases through Tandem Mass Spectrometry
Cargile, B. J., Bundy, J. L., & Stephenson, J. L. (2004) · Journal of Proteome Research · doi:10.1021/pr049946o · Cited by 197 · cited 2×
“Compared with cation-exchange chromatography, IPG IEF provides higher resolution separation and experimentally derived pI information, which can be used as a filter criterion for tandem mass spectral data validation (3, 4).”
MethodProtein fractionation in a multicompartment device using Off‐Gel™ isoelectric focusing
Michel, P. E., Reymond, F., Arnaud, I. L., Josserand, J., Girault, H. H., & Rossier, J. S. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200390030 · Cited by 165
Cargile, B. J., Talley, D. L., & Stephenson, J. L. (2004) · Electrophoresis · doi:10.1002/elps.200305722 · Cited by 163 · cited 7×
“the pI prediction is less good than in the acidic pH range (2).”
BackgroundMethodResultInfluentialEssader, A. S., Cargile, B. J., Bundy, J. L., & Stephenson, J. L. (2005) · PROTEOMICS · doi:10.1002/pmic.200400888 · Cited by 157
Cargile, B. J., Bundy, J. L., Freeman, T. W., & Stephenson, J. L. (2003) · Journal of Proteome Research · doi:10.1021/pr0340431 · Cited by 138
Michel, P., Crettaz, D., Morier, P., Heller, M., Gallot, D., Tissot, J., Reymond, F., & Rossier, J. S. (2006) · Electrophoresis · doi:10.1002/elps.200500680 · Cited by 114
Heller, M., Michel, P. E., Morier, P., Crettaz, D., Wenz, C., Tissot, J., Reymond, F., & Rossier, J. S. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200410106 · Cited by 113 · cited 1×
“OFFGEL electrophoresis or protein OFFGEL electrophoresis using wide range IPG gel strips with protein OFFGEL electrophoresis using narrow range IPG gel strips has already been shown (6).”
MethodSelf-citationHeller, M., Ye, M., Michel, P. E., Morier, P., Stalder, D., Jünger, M. A., Aebersold, R. H., Reymond, F., & Rossier, J. S. (2005) · Journal of Proteome Research · doi:10.1021/pr050193v · Cited by 101 · cited 2×
“focusing of predominantly basic and proline rich peptides (7).”
Background
Cited by
Wagner, S. A., Beli, P., Weinert, B. T., Nielsen, M. L., Cox, J., Mann, M., & Choudhary, C. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.013284 · Cited by 889
The quantitative proteome of a human cell line
Beck, M., Schmidt, A., Malmstroem, J., Claassen, M., Ori, A., Szymborska, A., Herzog, F., Rinner, O., Ellenberg, J., & Aebersold, R. (2011) · Molecular Systems Biology · doi:10.1038/msb.2011.82 · Cited by 816
Lee, E., Choi, D., Kim, D., Kim, J., Park, J. O., Kim, S., Kim, S., Desiderio, D. M., Kim, Y., Kim, K., et al. (2009) · PROTEOMICS · doi:10.1002/pmic.200900338 · Cited by 669
Silencing of microRNA families by seed-targeting tiny LNAs
Obad, S., dos Santos, C. O., Petri, A., Heidenblad, M., Broom, O., Ruse, C., Fu, C., Lindow, M., Stenvang, J., Straarup, E. M., et al. (2011) · Nature Genetics · doi:10.1038/ng.786 · Cited by 627
Proteomics: Challenges, Techniques and Possibilities to Overcome Biological Sample Complexity
Chandramouli, K., & Qian, P.-Y. (2009) · Human Genomics and Proteomics · doi:10.4061/2009/239204 · Cited by 511
Metadata
- Authors
- Hörth, P., Miller, C. A., Preckel, T., & Wenz, C.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 5
- Issue
- 10
- Pages
- 1968-1974
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2035003769
- Cited by
- 224
- References
- 10
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.