Interactive Peptide Spectral Annotator: A Versatile Web-based Tool for Proteomic Applications
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Here we present IPSA, an innovative web-based spectrum annotator that visualizes and characterizes peptide tandem mass spectra. A tool for the scientific community, IPSA can visualize peptides collected using a wide variety of experimental and instrumental configurations. Annotated spectra are customizable via a selection of interactive features and can be exported as editable scalable vector graphics to aid in the production of publication-quality figures. Single spectra can be analyzed through provided web forms, whereas data for multiple peptide spectral matches can be uploaded using the Proteomics Standards Initiative file formats mzTab, mzIdentML, and mzML. Alternatively, peptide identifications and spectral data can be provided using generic file formats. IPSA provides supports for annotating spectra collecting using negative-mode ionization and facilitates the characterization of experimental MS/MS performance through the optional export of fragment ion statistics from one to many peptide spectral matches. This resource is made freely accessible at http://interactivepeptidespectralannotator.com, whereas the source code and user guides are available at https://github.com/coongroup/IPSA for private hosting or custom implementations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
A cross-platform toolkit for mass spectrometry and proteomics
Chambers, M. C., Maclean, B., Burke, R., Amodei, D., Ruderman, D. L., Neumann, S., Gatto, L., Fischer, B., Pratt, B., Egertson, J., et al. (2012) · Nature Biotechnology · doi:10.1038/nbt.2377 · Cited by 4,093 · cited 1×
“MGF and mzML files can easily be generated from vendor or open file formats using conversion tools such as MSConvert (40).”
Method2016 update of the PRIDE database and its related tools
Vizcaíno, J. A., Csordas, A., del-Toro, N., Dianes, J. A., Griss, J., Lavidas, I., Mayer, G., Perez-Riverol, Y., Reisinger, F., Ternent, T., et al. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkv1145 · Cited by 3,451
Bostock, M., Ogievetsky, V., & Heer, J. (2011) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2011.185 · Cited by 3,165
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Open Mass Spectrometry Search Algorithm
Geer, L. Y., Markey, S. P., Kowalak, J. A., Wagner, L., Xu, M., Maynard, D. M., Yang, X., Shi, W., & Bryant, S. H. (2004) · Journal of Proteome Research · doi:10.1021/pr0499491 · Cited by 1,431 · cited 1×
“4.1) (32, 33).”
InfluentialPEAKS: powerful software for peptide de novo sequencing by tandem mass spectrometry
Ma, B., Zhang, K., Hendrie, C., Liang, C., Li, M., Doherty‐Kirby, A., & Lajoie, G. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1196 · Cited by 1,379
mzML—a Community Standard for Mass Spectrometry Data
Martens, L., Chambers, M., Sturm, M., Kessner, D., Levander, F., Shofstahl, J., Tang, W. H., Römpp, A., Neumann, S., Pizarro, A. D., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r110.000133 · Cited by 745 · cited 1×
“Spectral data can be uploaded as a Mascot Generic Format (MGF) or mzML file (12, 39).”
MethodHebert, A. S., Richards, A. L., Bailey, D. J., Ulbrich, A., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034769 · Cited by 528
Self-citationmMass data miner: an open source alternative for mass spectrometric data analysis
Strohalm, M., Hassman, M., Košata, B., & Kodíček, M. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3444 · Cited by 502
An Optimized Shotgun Strategy for the Rapid Generation of Comprehensive Human Proteomes
Bekker-Jensen, D. B., Kelstrup, C. D., Batth, T. S., Larsen, S. C., Haldrup, C., Bramsen, J. B., Sørensen, K. D., Høyer, S., Ørntoft, T. F., Andersen, C. L., et al. (2017) · Cell Systems · doi:10.1016/j.cels.2017.05.009 · Cited by 490
Johnson, R. S., Martin, S. A., Biemann, K., Stults, J. T., & Watson, J. T. (1987) · Analytical Chemistry · doi:10.1021/ac00148a019 · Cited by 451
Sequence database searches viade novo peptide sequencing by tandem mass spectrometry
Taylor, J. A., & Johnson, R. S. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970615)11:9<1067::aid-rcm953>3.0.co;2-l · Cited by 414
Scheltema, R. A., Hauschild, J.-P., Lange, O., Hornburg, D., Denisov, E., Damoc, E., Kuehn, A., Makarov, A., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.043489 · Cited by 323
Performance Evaluation of the Q Exactive HF-X for Shotgun Proteomics
Kelstrup, C. D., Bekker-Jensen, D. B., Arrey, T. N., Hogrebe, A., Harder, A., & Olsen, J. V. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00602 · Cited by 254
Senko, M. W., Remes, P. M., Canterbury, J. D., Mathur, R., Song, Q., Eliuk, S. M., Mullen, C., Earley, L., Hardman, M., Blethrow, J. D., et al. (2013) · Analytical Chemistry · doi:10.1021/ac403115c · Cited by 243
Reporting Protein Identification Data
Bradshaw, R. A., Burlingame, A. L., Carr, S., & Aebersold, R. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.e600005-mcp200 · Cited by 222 · cited 1×
“Proteomic field guidelines have increasingly emphasized the importance of providing access to annotated MS/MS spectra for publication, which allows others to inspect re-ported PSMs and validate their assignment to a given sequence (17–20).”
BackgroundYu, Q., Wang, B., Chen, Z., Urabe, G., Glover, M. S., Shi, X., Guo, L.-W., Kent, K. C., & Li, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1701-4 · Cited by 202
Perez‐Riverol, Y., Alpi, E., Wang, R., Hermjakob, H., & Vizcaíno, J. A. (2015) · PROTEOMICS · doi:10.1002/pmic.201400302 · Cited by 200
The mzIdentML Data Standard for Mass Spectrometry-Based Proteomics Results
Jones, A. R., Eisenacher, M., Mayer, G., Kohlbacher, O., Siepen, J., Hubbard, S. J., Selley, J. N., Searle, B. C., Shofstahl, J., Seymour, S. L., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014381 · Cited by 199 · cited 1×
“Identifications can be provided either in the Proteomics Standards Initiative file formats mzTab or mzIdentML, or in a generic CSV format (18, 19, 38).”
MethodpNovo: De novo Peptide Sequencing and Identification Using HCD Spectra
Chi, H., Sun, R.-X., Yang, B., Song, C.-Q., Wang, L.-H., Liu, C., Fu, Y., Yuan, Z.-F., Wang, H.-P., He, S.-M., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr100182k · Cited by 167
Griss, J., Jones, A. R., Sachsenberg, T. T., Walzer, M., Gatto, L., Hartler, J., Thallinger, G., Salek, R. M., Steinbeck, C., Neuhauser, N., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.036681 · Cited by 164 · cited 1×
“Identifications can be provided either in the Proteomics Standards Initiative file formats mzTab or mzIdentML, or in a generic CSV format (18, 19, 38).”
MethodCOMPASS: A suite of pre‐ and post‐search proteomics software tools for OMSSA
Wenger, C. D., Phanstiel, D. H., Lee, M. V., Bailey, D. J., & Coon, J. J. (2011) · PROTEOMICS · doi:10.1002/pmic.201000616 · Cited by 152 · cited 1×
“4.1) (32, 33).”
InfluentialSelf-citationLy, T., & Julian, R. R. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200900613 · Cited by 144 · cited 5×
“The authors found AI-ETD (cid:6) to be the optimal supplemental ETD fragmentation technique.”
BackgroundInfluentialComputational Methods for Understanding Mass Spectrometry–Based Shotgun Proteomics Data
Sinitcyn, P., Rudolph, J. D., & Cox, J. (2018) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-080917-013516 · Cited by 143
MS-Viewer: A Web-based Spectral Viewer for Proteomics Results
Baker, P. R., & Chalkley, R. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.037200 · Cited by 143 · cited 1×
“Most such tools are downloadable and often integrated directly into data-analysis suites, although a handful have been developed as web browser-based platforms (21– 23).”
BackgroundNow, More Than Ever, Proteomics Needs Better Chromatography
Shishkova, E., Hebert, A. S., & Coon, J. J. (2016) · Cell Systems · doi:10.1016/j.cels.2016.10.007 · Cited by 142
Self-citationOne-hour proteome analysis in yeast
Richards, A. L., Hebert, A. S., Ulbrich, A., Bailey, D. J., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2015) · Nature Protocols · doi:10.1038/nprot.2015.040 · Cited by 115 · cited 1×
“Low pH reverse-phase liquid chromatography was conducted using a Dionex UltiMate 3000 UPLC as described previously (1, 2).”
MethodSelf-citationRichards, A. L., Merrill, A. E., & Coon, J. J. (2015) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2014.10.017 · Cited by 106
Self-citationLedvina, A. R., Beauchene, N. A., McAlister, G. C., Syka, J. E. P., Schwartz, J. C., Griep-Raming, J., Westphall, M. S., & Coon, J. J. (2010) · Analytical Chemistry · doi:10.1021/ac1020358 · Cited by 71
Self-citationAnalysis of the Acidic Proteome with Negative Electron-Transfer Dissociation Mass Spectrometry
McAlister, G. C., Russell, J. D., Rumachik, N. G., Hebert, A. S., Syka, J. E. P., Geer, L. Y., Westphall, M. S., Pagliarini, D. J., & Coon, J. J. (2012) · Analytical Chemistry · doi:10.1021/ac203430u · Cited by 69
Self-citationRiffle, M., Jaschob, D., Zelter, A., & Davis, T. N. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00274 · Cited by 69
Improved Precursor Characterization for Data-Dependent Mass Spectrometry
Hebert, A. S., Thöing, C., Riley, N. M., Kwiecien, N. W., Shiskova, E., Huguet, R., Cardasis, H. L., Kuehn, A., Eliuk, S., Zabrouskov, V., et al. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04808 · Cited by 67
Self-citationThe Negative Mode Proteome with Activated Ion Negative Electron Transfer Dissociation (AI-NETD)
Riley, N. M., Rush, M. J. P., Rose, C. M., Richards, A., Kwiecien, N. W., Bailey, D. J., Hebert, A. S., Westphall, M. S., & Coon, J. J. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m115.049726 · Cited by 61 · cited 4×
“These include ETD; collisionally supplemented ETD (ETcaD and EThcD); AI-ETD; AI-NETD; and AI-ETD with supplemental infrared photon irradiation post-reaction (AI-ETD (cid:6) ) (34, 35).”
BackgroundMethodInfluentialSelf-citationRiley, N. M., Westphall, M. S., Hebert, A. S., & Coon, J. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00213 · Cited by 52 · cited 1×
“These include ETD; collisionally supplemented ETD (ETcaD and EThcD); AI-ETD; AI-NETD; and AI-ETD with supplemental infrared photon irradiation post-reaction (AI-ETD ) (34, 35).”
MethodSelf-citationMadsen, J. A., Xu, H., Robinson, M., Horton, A. P., Shaw, J., Giles, D. K., Kaoud, T. S., Dalby, K. N., Trent, M. S., & Brodbelt, J. S. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.028258 · Cited by 36 · cited 1×
“Alternative fragmentation techniques such as UVPD or AI-NETD, producing a/x-, b/y-, c/z-type and a/x-type product ions respectively, have recently demonstrated their utility in producing informative tandem mass spectra from peptide anions (35, 43).”
BackgroundA Mass Spectrometry Proteomics Data Management Platform
Sharma, V., Eng, J. K., MacCoss, M. J., & Riffle, M. E. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.015149 · Cited by 35
Characterizing Peptide Neutral Losses Induced by Negative Electron-Transfer Dissociation (NETD)
Rumachik, N. G., McAlister, G. C., Russell, J. D., Bailey, D. J., Wenger, C. D., & Coon, J. J. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0331-5 · Cited by 28
Self-citationA standardized framing for reporting protein identifications in mzIdentML 1.2
Seymour, S. L., Farrah, T., Binz, P., Chalkley, R. J., Cottrell, J. S., Searle, B. C., Tabb, D. L., Vizcaíno, J. A., Prieto, G., Uszkoreit, J., et al. (2014) · PROTEOMICS · doi:10.1002/pmic.201400080 · Cited by 26
On Credibility, Clarity, and Compliance
Burlingame, A. L., Carr, S. A., Bradshaw, R. A., & Chalkley, R. J. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.e115.052506 · Cited by 9
Cited by
LYTACs that engage the asialoglycoprotein receptor for targeted protein degradation
Ahn, G., Banik, S. M., Miller, C. L., Riley, N. M., Cochran, J. R., & Bertozzi, C. R. (2021) · Nature Chemical Biology · doi:10.1038/s41589-021-00770-1 · Cited by 619
Self-citationEDF1 coordinates cellular responses to ribosome collisions
Sinha, N. K., Ordureau, A., Best, K., Saba, J. A., Zinshteyn, B., Sundaramoorthy, E., Fulzele, A., Garshott, D. M., Denk, T., Thoms, M., et al. (2020) · eLife · doi:10.7554/elife.58828 · Cited by 177
“Spectrum annotation for RPS10 diGly site (Figure 2—figure supplement 2F) was generated using IPSA (Brademan et al., 2019).”
MethodBear, A. S., Blanchard, T., Cesare, J., Ford, M. J., Richman, L. P., Xu, C., Baroja, M. L., McCuaig, S., Costeas, C., Gabunia, K., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24562-2 · Cited by 113
Pervasive translation in Mycobacterium tuberculosis
Smith, C., Canestrari, J. G., Wang, A. J., Champion, M. M., Derbyshire, K. M., Gray, T. A., & Wade, J. T. (2022) · eLife · doi:10.7554/elife.73980 · Cited by 71
Human UFSP1 is an active protease that regulates UFM1 maturation and UFMylation
Millrine, D., Cummings, T., Matthews, S. P., Peter, J. J., Magnussen, H. M., Lange, S. M., Macartney, T., Lamoliatte, F., Knebel, A., & Kulathu, Y. (2022) · Cell Reports · doi:10.1016/j.celrep.2022.111168 · Cited by 71
Metadata
- Authors
- Brademan, D. R., Riley, N. M., Kwiecien, N. W., & Coon, J. J.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 18
- Issue
- 8
- Pages
- S193-S201
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2945463821
- Cited by
- 161
- References
- 42
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.