CoChat

Effect of Protocol on Determination of Velocity at V̇O2max and on its Time to Exhaustion

Billat, V. L., Hill, D. W., Pinoteau, J., Petit, B., Koralsztein, J.-P. · 1996 · Archives of Physiology and Biochemistry
Cited by 100

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The velocity associated with the achievement of VO2 max during an incremental treadmill test (v VO2 max) has been reported to be an indicator of performance in middle distance running events. Previous study has shown the reproducibility of the time to exhaustion (time limit: tlim) at v VO2 max performed by well-trained males in the same condition at one week of interval (Billat et al., 1994b). It is essential in studies involving tlim at v VO2 max that the v VO2 max be precisely determined, or else the measured tlim will be meaningless. The purpose of this study was to examine the influence of the stage duration and velocity incrementation on the velocity at VO2 max and, consequently, on the two times to exhaustion (tlim) associated with the two v VO2 max generated by the two protocols. v VO2 max was determined in 15 trained male endurance athletes as the lowest speed at which VO2 max was attained in speed-incremented 0%-slope treadmill tests. For one test, increments were 1.0 km.h-1 and stages were 2 min in duration; for the other test, increments were 0.5 km.h-1 and stages were 1 min in duration. Results of paired means t-tests revealed no difference in v VO2 max obtained using the two protocols. v VO2 max was 20.7 +/- 1.0 km.h-1 with the 1.0 km.h-1 x 2 min protocol and 20.8 +/- 0.9 km.h-1 with the 0.5 km.h-1 x 1 min protocol. In addition, VO2, VCO2, VE, VE/VO2 and respiratory exchange ratio at the submaximal intensities that were common to both protocols (e.g., 17.0 km.h-1, 18.0 km.h-1, 19.0 km.h-1, 20.0 km.h-1) did not differ. Times to exhaustion at the two v VO2 max demonstrated a high degree of inter-individual variability (coefficients of variation were 35% and 45%) but did not differ (345 +/- 120 s versus 373 +/- 169 s). These results demonstrated that small changes in protocol have no significant impact on the value of v VO2 max and in consequence on tlim v VO2 max.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1076/apab.104.3.313.12908

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 100

Metadata

Authors
Billat, V. L., Hill, D. W., Pinoteau, J., Petit, B., & Koralsztein, J.-P.
Venue
Archives of Physiology and Biochemistry
Published
1996-01
Volume
104
Issue
3
Pages
313-321
ISSN
  • 0778-3124 (ISSN-L)
  • 1381-3455
  • 1744-4160
OpenAlex
W2162196074
Cited by
100
References
2
FWCI
4.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Protocol on Determination of Velocity at V̇O2max and on its Time to Exhaustion. https://app.cochat.ai/papers/10.1076/apab.104.3.313.12908
The paper
Billat, V. L., Hill, D. W., Pinoteau, J., Petit, B., & Koralsztein, J.-P. (1996). Effect of Protocol on Determination of Velocity at V̇O2max and on its Time to Exhaustion. Archives of Physiology and Biochemistry. https://doi.org/10.1076/apab.104.3.313.12908

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.