High Level Runners Are Able to Maintain a VO2 Steady-State Below VO2max in an All-Out Run Over Their Critical Velocity
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
During prolonged and intense running exercises beyond the critical power level, a VO2 slow component elevates VO2 above predicted VO2-work rates calculated from exercise performed at intensities below the lactate threshold. In such cases, the actual VO2 value will increase over time until it reaches VO2max. The aims of the present study were to examine whether the VO2 slow component is a major determinant of VO2 over time when running at a speed beyond critical velocity, and whether the exhaustion latency period at such intensity correlates with the magnitude of the VO2 slow component. Fourteen highly trained long-distance runners performed four exhaustive runs, each separated by one week of light training. VO2 and the velocity at VO2max (vVO2max) were determined for each by a graded treadmill exercise. The critical velocity (86.1 +/- 1.5% vVO2max) of each runner was calculated from exhaustive treadmill runs at 90, 100 and 105% of vVO2max. During supra-critical velocity runs at 90% of vVO2max, there was no significant rise in VO2max (20.9 +/- 2.1 ml min-1 kg-1 between the third and last min of tlim 90), such that the runners reached a VO2 steady-state, but did not reach their vVO2max level over time (69.5 +/- 5.0 vs 74.9 +/- 3.0 ml min-1 kg-1). Thus, subjects' time to exhaustion at 90% of vVO2max was not correlated with the VO2max slow component (r = 0.11, P = 0.69), but significantly correlated with the lactate threshold (r = 0.54, P = 0.04) and the critical velocity (% vVO2max; r = 0.65, P = 0.01). In conclusion, the present study demonstrates that for highly trained long-distance runners performing exhaustive, supra-critical velocity runs at 90% of vVO2max, there was not a VO2 slow component tardily completing the rise of VO2. Instead, runners will maintain a VO2 steady-state below VO2max, such that the time to exhaustion at 90% of vVO2max for these runners is positively correlated with the critical velocity expressed as % of vVO2max.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sahlin, K. (1992) · Sports Medicine · doi:10.2165/00007256-199213020-00005 · Cited by 201
Reproducibility of aerobic and anaerobic thresholds in 20–50 year old men
Aunola, S., & Rusko, H. (1984) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00776600 · Cited by 141
Cited by
Buchheit, M., & Laursen, P. B. (2013) · Sports Medicine · doi:10.1007/s40279-013-0029-x · Cited by 1,490
Laursen, P. B., & Jenkins, D. G. (2002) · Sports Medicine · doi:10.2165/00007256-200232010-00003 · Cited by 1,011
Buchheit, M., & Laursen, P. B. (2013) · Sports Medicine · doi:10.1007/s40279-013-0066-5 · Cited by 869
Billat, L. V. (2001) · Sports Medicine · doi:10.2165/00007256-200131010-00002 · Cited by 663
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Billat, V. L., Sirvent, P., Py, G., Koralsztein, J.-P., & Mercier, J. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00003 · Cited by 397
Self-citationOxygen uptake kinetics in treadmill running and cycle ergometry: a comparison
Carter, H., Jones, A. M., Barstow, T. J., Burnley, M., Williams, C. A., & Doust, J. H. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.3.899 · Cited by 252
A Perspective on High-Intensity Interval Training for Performance and Health
Coates, A. M., Joyner, M. J., Little, J. P., Jones, A. M., & Gibala, M. J. (2023) · Sports Medicine · doi:10.1007/s40279-023-01938-6 · Cited by 246
Billat, V. L., Slawinski, J., Bocquet, V., Demarle, A., Lafitte, L., Chassaing, P., & Koralsztein, J.-P. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050029 · Cited by 221
Self-citationParmar, A., Jones, T. W., & Hayes, P. (2021) · Journal of Sports Sciences · doi:10.1080/02640414.2021.1876313 · Cited by 29
Metadata
- Authors
- Billat, V., Binsse, V., Petit, B., & Koralsztein, J. J. P.
- Venue
- Archives of Physiology and Biochemistry
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 106
- Issue
- 1
- Pages
- 38-45
- ISSN
- 0778-3124 (ISSN-L)
- 1381-3455
- 1744-4160
- OpenAlex
- W2043785257
- Cited by
- 78
- References
- 2
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.