The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Design and Accuracy of Calipers for Measuring Subcutaneous Tissue Thickness
Open accessAbstract
A considerable proportion of the body fat lies in the subcutaneous tissue which, in many parts of the body, is only loosely attached to the underlying tissue and can be pulled up between the thumb and forefinger into a fold (Pl.I).The thickness of this fold of skin and subcutaneous tissues can be measured by applying some form of caliper to either side of it, and this technique has been widely used to give an estimate of body fat by those concerned with nutrition (Sinclair, 1948;Keys & Broiek, 1953), with fat distribution (Edwards, 1950), with child growth (Franzen, 1929;Reynolds, 1950;Tanner, 1953) and with anthropometric surveys (Berry, Cowin & Magee, 1951 ;Hammond, 1953).However, the observed thickness depends on how the skinfold is picked up and on the design of the caliper with which it is measured; if, for example, the jaws of the caliper are approximated by a spring the reading will depend on the strength of the spring, since the tissue is compressible.Despite these facts, there has been little information published on the best design of skinfold calipers, and no general standardization either of instrument or of technique.Hence the comparison of the results of different observers is usually impossible, and much work in the field is vitiated.The purpose of the present investigation was (a) to test various designs of caliper and to recommend principles that all calipers should follow, and (b) to introduce, and test the accuracy of, a new skinfold caliper which we believe to be the most satisfactory yet produced.The paper is divided into two parts : Part I describes two experiments on caliper design and ends with a set of general recommendations; Part z describes the new caliper and gives the results of three experiments made to assess its accuracy in practical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keys, A., & BroŽek, J. (1953) · Physiological Reviews · doi:10.1152/physrev.1953.33.3.245 · Cited by 856
The Evaluation of Leanness-Fatness in Man: Norms and Interrelationships
Brožek, J., & Keys, A. (1951) · British Journal of Nutrition · doi:10.1079/bjn19510025 · Cited by 270
Cited by
Durnin, J. V. G. A., & Womersley, J. (1974) · British Journal of Nutrition · doi:10.1079/bjn19740060 · Cited by 6,343
The assessment of the amount of fat in the human body from measurements of skinfold thickness
Durnin, J. V. G. A., & Rahaman, M. M. (1967) · British Journal of Nutrition · doi:10.1079/bjn19670070 · Cited by 1,685
Methods for the assessment of human body composition: traditional and new
Lukaski, H. C. (1987) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/46.4.537 · Cited by 1,152
Eriksson, K. F., & Lindg�rde, F. (1991) · Diabetologia · doi:10.1007/bf00400196 · Cited by 1,092
Indices of obesity derived from body weight and height.
Khosla, T., & Lowe, C. R. (1967) · Journal of Epidemiology & Community Health · doi:10.1136/jech.21.3.122 · Cited by 552
Metadata
- Authors
- Edwards†, D. A. W., Hammond, W. H., Healy, M. J. R., Tanner, J. M., & Whitehouse, R. H.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 1955-05
- Volume
- 9
- Issue
- 2
- Pages
- 133-143
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W1984805780
- Cited by
- 446
- References
- 2
- FWCI
- 15.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Accuracy of Calipers for Measuring Subcutaneous Tissue Thickness. https://app.cochat.ai/papers/10.1079/bjn19550021
- The paper
- Edwards†, D. A. W., Hammond, W. H., Healy, M. J. R., Tanner, J. M., & Whitehouse, R. H. (1955). Design and Accuracy of Calipers for Measuring Subcutaneous Tissue Thickness. British Journal of Nutrition. https://doi.org/10.1079/bjn19550021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.