Deuterium dilution as a method for determining total body water: effect of test protocol and sampling time
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Deuterium dilution for the measurement of total body water (TBW) has been conducted using varying protocols for equilibration. We measured TBW from deuterium dilution in urine samples in twenty-eight subjects using three protocols: (1) early morning dosage without breakfast, measuring deuterium in a second voiding at 4h and 6h; (2) early morning dosage with breakfast with the same measurement times; (3) dosage as last consumption before overnight sleep, measuring deuterium in a second voiding at 10 h. Results were compared with TBW estimates from underwater weighing (UWW). Because UWW is an indirect measure of TBW, it is used as an independent reference method in order to compare only relative discrepancies between the two methods. TBW values in the fasted state were not significantly different from those obtained in the fed state. The urinary deuterium enrichment was higher at 4 h than at 6 h (resulting TBW differences: 0·6 (SD 0·4)I). At 4h and 6h, differences in TBW measurements from deuterium and densitometry were positively related to the amount of TBW, indicating incomplete equilibration in larger water compartments. At 10h no such relationship existed, indicating complete mixing of deuterium. It is concluded that 10h equilibration is preferable to the shorter 4h and 6h, for the determination of TBW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Total body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
Cited by
Lejeune, M. P., Westerterp, K. R., Adam, T. C., Luscombe-Marsh, N. D., & Westerterp-Plantenga, M. S. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.1.89 · Cited by 363
“Body composition was determined by the 3 compartment model, with the use of hydrodensitometry and the deuterium dilution ((2)H2O) technique (24, 25), and was calculated by using the combined equation of Siri (26).”
MethodSelf-citationWesterterp‐Plantenga, M. S., Lejeune, M. P. G. M., & Kovacs, E. M. R. (2005) · Obesity Research · doi:10.1038/oby.2005.142 · Cited by 328
High protein intake sustains weight maintenance after body weight loss in humans
Westerterp-Plantenga, M. S., Lejeune, M. P. G. M., Nijs, I., van Ooijen, M., & Kovacs, E. M. R. (2004) · International Journal of Obesity · doi:10.1038/sj.ijo.0802461 · Cited by 326
Westerterp, K. R., Wouters, L., & van Marken Lichtenbelt, W. D. (1995) · Obesity Research · doi:10.1002/j.1550-8528.1995.tb00007.x · Cited by 326
Self-citationValidity of physical activity monitors during daily life in patients with COPD
Rabinovich, R. A., Louvaris, Z., Raste, Y., Langer, D., Van Remoortel, H., Giavedoni, S., Burtin, C., Regueiro, E. M. G., Vogiatzis, I., Hopkinson, N. S., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00134312 · Cited by 293
Self-citation
Metadata
- Authors
- Van Marken Lichtenbelt, W. D., Westerterp, K. R., & Wouters, L.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 1994-10
- Volume
- 72
- Issue
- 4
- Pages
- 491-497
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2026990037
- Cited by
- 128
- References
- 2
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.