CoChat

Importance of measuring CO2-production rate when using 13C-breath tests to measure fat digestion

Open access
Amarri, S., Coward, W. A., Harding, M., Weaver, L. T. · 1998 · British Journal of Nutrition
Cited by 52

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Stable isotope breath tests offer a safe, repeatable non-invasive method of measuring fat digestion. They involve the ingestion of a substrate labelled with 13 C followed by serial measurements of the 13 C: 12 C ratio in expired CO 2, from which the percentage of the 13 C dose recovered (PDR) can be calculated. However PDR depends on the CO 2-production rate. Our aim was to compare results obtained using directly measured CO 2-production rates with those calculated from two predicted values. Twelve normal healthy children and twenty-four children with cystic fibrosis (CF) (without or with the normal dose of enzyme supplementation) were studied with 1,3-distearyl, 2[carboxyl[13 C]octanoyl glycerol. The volume of CO 2 produced (litres/min) was measured at rest for 30 min approximately 3 h after substrate ingestion, and the results were converted to mmol/min. For each subject the expected BMR was calculated from the equation of Schofield (1985), based on sex, age, weight and height, and from these values, CO 2-production rate was derived. Surface area was calculated and an estimated value of 5 mmol/m 2 per min (Shreeve et al. 1970) was used. Using these three CO 2-production rates, three different PDR were calculated and compared. In healthy children there was a close concordance between measured and predicted CO 2-production rates, but children with CF had a mean measured CO 2-production rate 39% higher than normal children. This use of normal data for predicted CO 2-production rates in children with CF underestimates cumulative PDR. If direct measurements of CO 2-production rate are not available or impossible to perform the Vco 2 obtained from the BMR calculated using the equations of Schofield (1985) or Shreeve et al. (1970) can be used in normal children. However, if accurate results for PDR are to be obtained, CO 2-production rates should be measured when performing breath tests in conditions where energy expenditure and/or CO 2-production rate are not expected to be normal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1079/bjn19980093

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 52

Metadata

Authors
Amarri, S., Coward, W. A., Harding, M., & Weaver, L. T.
Venue
British Journal of Nutrition
Published
1998-06
Volume
79
Issue
6
Pages
541-545
ISSN
  • 0007-1145 (ISSN-L)
  • 1475-2662
OpenAlex
W2062396101
Cited by
52
References
1
FWCI
3.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.