Description and validation of the ActiReg®: a novel instrument to measure physical activity and energy expenditure
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The ActiReg® (PreMed AS, Oslo, Norway) system is unique in using combined recordings of body position and motion alone or combined with heart rate (HR) to calculate energy expenditure (EE) and express physical activity (PA). The ActiReg® has two pairs of position and motion sensors connected by cables to a battery-operated storage unit fixed to a waist belt. Each pair of sensors was attached by medical tape to the chest and to the front of the right thigh respectively. The collected data were transferred to a personal computer and processed by a dedicated program ActiCalc®. Calculation models for EE with and without HR are presented. The models were based on literature values for the energy costs of different activities and therefore require no calibration experiments. The ActiReg® system was validated against doubly labelled water (DLW) and indirect calorimetry. The DLW validation demonstrated that neither EE calculated from ActiReg® data alone (EE AR) nor from combined ActiReg® and HR data (EE AR–HR) were statistically different from DLW results. The EE AR procedure causes some underestimation of EE >11 MJ corresponding to a PA level >2·0. This underestimation is reduced by the EE AR–HR procedure. The objective recording of the time spent in different body positions and at different levels of PA may be useful in studies of PA in different groups and in studies of whether recommendations for PA are being met. The comparative ease of data collection and calculation should make ActiReg® a useful instrument to measure habitual PA level and EE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473 · cited 2×
“The recent publication of experiments with combined accelerometer and HR recording is therefore interesting (Brage et al. 2003a).”
BackgroundHealth consequences of physical activity: understanding and challenges regarding dose-response
HASKELL, W. L. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199406000-00001 · Cited by 363
Cited by
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
JOHANNSEN, D. L., CALABRO, M. A., STEWART, J., FRANKE, W., ROOD, J. C., & WELK, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 424
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Kurtze, N., Rangul, V., Hustvedt, B.-E., & Flanders, W. D. (2008) · Scandinavian Journal of Public Health · doi:10.1177/1403494807085373 · Cited by 330
Self-citation
Metadata
- Authors
- Hustvedt, B.-E., Christophersen, A., Johnsen, L. R., Tomten, H., McNeill, G., Haggarty, P., & Løvø, A.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2004-12
- Volume
- 92
- Issue
- 6
- Pages
- 1001-1008
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2108373199
- Cited by
- 69
- References
- 4
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.