Curve of amniotic fluid index measurements in low-risk pregnancy
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Objectives. To establish a curve of amniotic fluid index [AFI] measurements from the 20th to the 42nd week of pregnancy. Methods. A prospective and descriptive study was performed, in which an independent sample of 2,868 low‐risk pregnant women were studied using routine ultrasound, including fetal biometry and measurement of AFI. Data were analysed using multiple linear regression, and constructing a curve using 2.5th, 10th, 50th, 90th and 97.5th percentiles of the AFI measurements, according to gestational age, and after submitting values to smoothing process using quadratic polynomial adjustment. Results. There was a significant variation in AFI measurements at the different gestational ages. The 50th percentile remained practically constant at approximately 150 mm between the 20th and 33rd week, after which there was a decline in volume, which became evident after the 38th week. At the 40th week, the 10th percentile was around 62 mm and the 2.5th percentile around 33 mm. Conclusions. The curve of percentiles of AFI measurements in low‐risk pregnant women showed significant decrease with gestational age, especially after the 33rd week. These data should be validated for a diagnosis of increased or decreased volumes of amniotic fluid at specific gestational ages.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Using a recent nomogram, 24 cm exceeds the 97.5th percentile for all gestational ages between 20e42 weeks.21”
From SMFM Consult Series #46: Evaluation and management of polyhydramnios (2018) · cites this paper as [21]
Citations
Cites
Antepartum fetal evaluation: Development of a fetal biophysical profile
Manning, F. A., Platt, L. D., & Sipos, L. (1980) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(80)90457-3 · Cited by 770 · cited 1×
“The normal lower and upper limit values of the AFI commonly used up to now, which vary between 50 and 200 mm (7,9), are similar to those found in the present study up to the 40th week of pregnancy.”
(1987) · PubMed · Cited by 639
The amniotic fluid index in normal human pregnancy
Moore, T. R., & Cayle, J. E. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90009-v · Cited by 554 · cited 1×
“When we compare the results of this study to previous published curves (3,12), similarities can be seen for the 50th percentile of AFI at all gestational ages.”
ResultUltrasound evaluation of amniotic fluid volume
Chamberlain, P. F., Manning, F. A., Morrison, I., Harman, C. R., & Lange, I. R. (1984) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(84)90359-4 · Cited by 535 · cited 1×
“For the fetal biophysical profile, the measurement of just one pocket is adopted, varying from 1 to 3 cm, and considered the lower normal limit by some authors (21,22); however, in this case, total volume would be considered decreased if the AFI were used.”
Background(1988) · Journal of Diagnostic Medical Sonography · doi:10.1177/875647938800400131 · Cited by 377 · cited 1×
“When adopting reference values between 80 and 180 mm for every week of pregnancy (19,20), incorrect diagnosis are likely to occur.”
MethodNormal amniotic fluid volume changes throughout pregnancy
Brace, R. A., & Wolf, E. J. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90527-9 · Cited by 356 · cited 2×
“The importance of variations in volume of amniotic fluid to fetal well-being has been particularly well-established, and are closely correlated to an increase in perinatal mortality and morbidity rates (3,4), although some doubts have recently been raised (5).”
BackgroundResultThe amniotic fluid index, single deepest pocket, and two-diameter pocket in normal human pregnancy
Magann, E. F., Sanderson, M., Martin, J. N., & Chauhan, S. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.107325 · Cited by 204
Diagnostic ultrasound of fetal anomalies : text and atlas
Nyberg, D. A., MAHONY, B. S., & Pretorius, D. (1990) · Medical Entomology and Zoology · Cited by 168
Reevaluation of the relationship between amniotic fluid volume and perinatal outcome
Ott, W. J. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.062 · Cited by 110 · cited 1×
“The importance of variations in volume of amniotic fluid to fetal well-being has been particularly well-established, and are closely correlated to an increase in perinatal mortality and morbidity rates (3,4), although some doubts have recently been raised (5).”
BackgroundUltrasonography in Obstetrics and Gynecology
Goldberg, B. B. (1983) · JAMA · doi:10.1001/jama.1983.03340130091048 · Cited by 84
Chauhan, S. P., Doherty, D. D., Magann, E. F., Cahanding, F., Moreno, F. V., & Klausen, J. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.078 · Cited by 82
Alteration of the amniotic fluid and neonatal outcome.
Volante, E., Gramellini, D., Moretti, S., Kaihura, C. T., & Bevilacqua, G. (2004) · PubMed · Cited by 69
Alfirević, Ž., Luckas, M. J. M., Walkinshaw, S. A., McFarlane, M., & Curran, R. (1997) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb11046.x · Cited by 66 · cited 1×
“In fact, a RCT comparing both techniques showed an overestimation of abnormal results with AFI in post term pregnancies, increasing the number of obstetric interventions (23).”
BackgroundDo semiquantitative amniotic fluid indexes reflect actual volume?
Croom, C. S., Banias, B. B., Ramos-Santos, E., Devoe, L. D., Bezhadian, A., & Hiett, A. K. (1992) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(12)80026-3 · Cited by 62 · cited 1×
“Both methods show good correlation between the measurements and the actual volume of amniotic fluid (10).”
Longitudinal assessment of amniotic fluid index
Nwosu, E. C., Welch, C. R., Manasse, P., & Walkinshaw, S. (1993) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1993.tb14305.x · Cited by 49 · cited 1×
“A longitudinal assessment of AFI, performed in the UK, also showed lower limits significantly higher than those of cross-sectional studies, with probable different clinical performance (17).”
ResultAmniotic fluid index measurement with the four-quadrant technique during pregnancy.
Jeng, C., Jou, T., Wang, K.-G., Yang, Y., Lee, Y. N., & Lan, C. (1990) · PubMed · Cited by 39
Youssef, A. A., Abdulla, S. A., Sayed, E. H., Salem, H. T., Abdelalim, A. M., & Devoe, L. D. (1993) · Southern Medical Journal · doi:10.1097/00007611-199304000-00011 · Cited by 37 · cited 1×
“For the fetal biophysical profile, the measurement of just one pocket is adopted, varying from 1 to 3 cm, and considered the lower normal limit by some authors (21,22); however, in this case, total volume would be considered decreased if the AFI were used.”
BackgroundAmniotic fluid index measurements in normal pregnancy after 28 gestational weeks
Hinh, N. D., & Ladinsky, J. L. (2005) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2005.07.007 · Cited by 30
Sonographic Evaluation of Amniotic Fluid Volume
Schrimmer, D. B., & Moore, T. R. (2002) · Clinical Obstetrics & Gynecology · doi:10.1097/00003081-200212000-00009 · Cited by 29 · cited 1×
“Fetal well-being is an important question that can, however, remain unanswered in many situations, but progress in diagnostic techniques has resulted in better perinatal outcomes, and has also contributed to understanding the complex physiological and pathological interaction between fetus and mother (1,2).”
BackgroundNormal Amniotic Fluid Index by Gestational Week in a Chinese Population
LEI, H., & WEN, S. W. (1998) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00158-6 · Cited by 21 · cited 3×
“When the 50th percentile AFI was compared with that reported in a Chinese study (14), measurements were always higher in our population at all gestational ages by approximately 50 mm up to 28 weeks, and by 30 40 mm between 32 and 40 weeks of pregnancy.”
BackgroundMethodResultInfluentialKhadilkar, S. S., Desai, S. S., Tayade, S. M., & Purandare, C. N. (2003) · Journal of obstetrics and gynaecology research · doi:10.1046/j.1341-8076.2003.00089.x · Cited by 21 · cited 1×
“On the other hand, the current 50th percentile showed fewer variations, around 10 mm at all gestational ages, compared to the results of the Indian study population (15).”
ResultPredictive Value of Amniotic Fluid Volume Measurements on Perinatal Outcome
Ergün, A., Atay, V., Pabuçcu, R., Başer, İ., Duru, N. K., & Tokaç, G. (1998) · Gynecologic and Obstetric Investigation · doi:10.1159/000009917 · Cited by 7 · cited 1×
“The reference curves established some years ago are still in use in current obstetrical practice, but there is a need for new data, using a reliable reference low-risk pregnant women sample, to establish the limits of AFI that would indicate perinatal risk (6).”
BackgroundMachado, M. R. M., Cecatti, J. G., dos Santos, F. F. A., Marussi, E. F., & Parpinelli, M. Â. (2003) · Revista Brasileira Ginecologia e Obstetrícia · doi:10.1590/s0100-72032003000900004 · Cited by 3 · cited 1×
“There were no significant differences in mean AFI measurements when these data were controlled for age, race, literacy, smoking habit, parity or previous caesarean scar (data already published elsewhere) (18).”
Background
Cited by
SMFM Consult Series #46: Evaluation and management of polyhydramnios
Dashe, J. S., Pressman, E. K., & Hibbard, J. U. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.07.016 · Cited by 135
Amniotic Fluid and the Clinical Relevance of the Sonographically Estimated Amniotic Fluid Volume
Magann, E. F., Sandlin, A. T., & Ounpraseuth, S. (2011) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2011.30.11.1573 · Cited by 104
Prenatal diagnosis of congenital renal and urinary tract malformations.
Hindryckx, A., & Catte, L. D. (2011) · PubMed Central · Cited by 77
Hebbar, S., Rai, L., Adiga, P., & Guruvare, S. (2015) · Journal of Pregnancy · doi:10.1155/2015/319204 · Cited by 36
Owen, J., Albert, P. S., Louis, G. M. B., Fuchs, K. M., Grobman, W. A., Kim, S., D’Alton, M. E., Wapner, R. J., Wing, D. A., & Grantz, K. L. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2019.02.030 · Cited by 34
Metadata
- Authors
- REGINA MACHADO, M., GUILHERME CECATTI, J., KRUPA, F., & FAUNDES, A.
- Affiliations
- Universidade Estadual de Campinas (UNICAMP) (BR)
- Venue
- Acta Obstetricia et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2007-01
- Volume
- 86
- Issue
- 1
- Pages
- 37-41
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2103413556
- Cited by
- 19
- References
- 23
- Citations by year
- 2021: 2 · 2020: 2 · 2019: 1 · 2018: 2 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 3
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Acta Obstetricia Et Gynecologica Scandinavica (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Keywords
- amniotic fluid index, reference percentiles, gestational age, low-risk pregnancy, amniotic fluid volume, fetal biometry, prenatal ultrasound
- MeSH terms
- Adolescent, Adult, Amniotic Fluid, Female, Gestational Age, Humans, Middle Aged, Pregnancy, Pregnancy Trimester, Second, Pregnancy Trimester, Third, Prospective Studies, Reference Values, Linear Models, Ultrasonography, Prenatal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.