Interaction between the ACL graft and MCL in a combined ACL+MCL knee injury using a goat model
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The optimal treatment for the MCL in the combined ACL and MCL-injured knee is still controversial. Therefore, we designed this study to examine the mechanical interaction between the ACL graft and the MCL in a goat model using a robotic/universal force-moment sensor testing system. The kinematics of intact, ACL-deficient, ACL-reconstructed, and ACL-reconstructed/ MCL-deficient knees, as well as the in situ forces in the ACL, ACL graft, and MCL were determined in response to two external loading conditions: 1) anterior tibial load of 67 N and 2) valgus moment of 5 N-m. With an anterior tibial load, anterior tibial translation in the ACL-deficient knee significantly increased from 2.0 and 2.2 mm to 15.7 and 18.1 mm at 30 degrees and 60 degrees of knee flexion, respectively. The in situ forces in the MCL also increased from 8 to 27 N at 60 degrees of knee flexion. ACL reconstruction reduced the anterior tibial translation to within 2 mm of the intact knee and significantly reduced the in situ force in the MCL to 17 N. However, in response to a valgus moment, the in situ forces in the ACL graft increased significantly by 34 N after transecting the MCL. These findings show that ACL deficiency can increase the in situ forces in the MCL while ACL reconstruction can reduce the in situ forces in the MCL in response to an anterior tibial load. On the other hand, the ACL graft is subjected to significantly higher in situ forces with MCL deficiency during an applied valgus moment. Therefore, the ACL-reconstructed knee with a combined ACL and MCL injury should be protected from high valgus moments during early healing to avoid excessive loading on the graft.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ballock, R. T., Woo, S. L., Lyon, R. M., Hollis, J. M., & Akeson, W. H. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070404 · Cited by 230 · cited 1×
“However, these models have proved to have limited long-term success, as results of ACL reconstruction in rabbits have been highly variable due to its small size (Ballock et al. 1989, Engle et al. 1994, Ohno et al. 1995, Yamaji et al. 1996).”
BackgroundSelf-citation
Cited by
Papageorgiou, C. D., Ma, C. B., Abramowitch, S. D., Clineff, T. D., & Woo, S. L.-Y. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290051501 · Cited by 190
Self-citationManagement of Medial-Sided Knee Injuries, Part 1: Medial Collateral Ligament
Marchant, M. H., Tibor, L. M., Sekiya, J. K., Hardaker, W. T., Garrett, W. E., & Taylor, D. C. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510385999 · Cited by 124
Basic Science of Ligament Healing: Medial Collateral Ligament Healing With and Without Treatment
Creighton, R. A., Spang, J. T., & Dahners, L. E. (2005) · Sports Medicine and Arthroscopy Review · doi:10.1097/01.jsa.0000173623.62717.03 · Cited by 25
Gamada, K. (2014) · International Journal of Physical Medicine & Rehabilitation · doi:10.4172/2329-9096.1000246 · Cited by 12
“[201], who utilized the robot/universal force sensor system to determine the in situ forces of the ACL and MCL in response to valgus load.”
Metadata
- Authors
- Ma, C. B., Papageogiou, C. D., Debski, R. E., & Woo, S. L.-Y.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 2000-01
- Volume
- 71
- Issue
- 4
- Pages
- 387-393
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2040334996
- Cited by
- 73
- References
- 1
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interaction between the ACL graft and MCL in a combined ACL+MCL knee injury using a goat model. https://app.cochat.ai/papers/10.1080/000164700317393394
- The paper
- Ma, C. B., Papageogiou, C. D., Debski, R. E., & Woo, S. L.-Y. (2000). Interaction between the ACL graft and MCL in a combined ACL+MCL knee injury using a goat model. Acta Orthopaedica Scandinavica. https://doi.org/10.1080/000164700317393394
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.