The DOI matches its Crossref record.
Size Considerations for Establishing a Standard for Inhalable Particles
Open accessAbstract
The U. S. Environmental Protection Agency (EPA) is required, under the amended Clean Air Act of 1977, to review the scientific basis for the total suspended par-ticulate (TSP) ambient air quality standard and determine whether a revised particulate standard can be promulgated by December, 1980. It is recommended that research to develop information for a size-specific standard should focus on inhalable particulate (IP) matter defined as airborne particles ≤15 jum aerodynamic equivalent diameter. This particle size range relates to that fraction of particulate matter which can primarily deposit in the conducting airways and the gas-exchange areas of the human respiratory system during mouth breathing. It is also recommended that a second particle size cut-point of ≤2.5 yum diameter be incorporated in the air sampling devices, based upon considerations of the chemical composition and the size distribution of airborne particles, and on the predominant penetration of particles ≤2.5 /im diameter into the gas-exchange region of the respiratory tract. Data collected in this size range could be used in conjunction with epidemiological health parameters to refine an inhalable particulate standard in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Richter, H., & Howard, J. B. (2000) · Progress in Energy and Combustion Science · doi:10.1016/s0360-1285(00)00009-5 · Cited by 1,833
Organic atmospheric aerosols: Review and state of the science
Jacobson, M. C., Hansson, H. ‐., Noone, K. J., & Charlson, R. J. (2000) · Reviews of Geophysics · doi:10.1029/1998rg000045 · Cited by 731
Thoracic and Respirable Particle Definitions for Human Health Risk Assessment
Brown, J. S., Gordon, T., Price, O., & Asgharian, B. (2013) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-10-12 · Cited by 474
Ambient Particles and Health: Lines that Divide
Vedal, S. (1997) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1997.10463922 · Cited by 402
Metadata
- Authors
- Miller, F. J., Gardner, D. E., Graham, J. A., Lee, R. E., Wilson, W. E., & Bachmann, J. D.
- Venue
- Journal of the Air Pollution Control Association
- Publisher
- Informa UK Limited
- Published
- 1979-06
- Volume
- 29
- Issue
- 6
- Pages
- 610-615
- ISSN
- 0002-2470 (ISSN-L)
- OpenAlex
- W2008537392
- Cited by
- 175
- References
- 0
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Size Considerations for Establishing a Standard for Inhalable Particles. https://app.cochat.ai/papers/10.1080/00022470.1979.10470831
- The paper
- Miller, F. J., Gardner, D. E., Graham, J. A., Lee, R. E., Wilson, W. E., & Bachmann, J. D. (1979). Size Considerations for Establishing a Standard for Inhalable Particles. Journal of the Air Pollution Control Association. https://doi.org/10.1080/00022470.1979.10470831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.