Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Thoracic and respirable particle definitions for human health risk assessment

Open access
Brown, James S, Gordon, Terry, Price, Owen, Asgharian, Bahman · 2013 · Particle and Fibre Toxicology

Abstract

BACKGROUND: Particle size-selective sampling refers to the collection of particles of varying sizes that potentially reach and adversely affect specific regions of the respiratory tract. Thoracic and respirable fractions are defined as the fraction of inhaled particles capable of passing beyond the larynx and ciliated airways, respectively, during inhalation. In an attempt to afford greater protection to exposed individuals, current size-selective sampling criteria overestimate the population means of particle penetration into regions of the lower respiratory tract. The purpose of our analyses was to provide estimates of the thoracic and respirable fractions for adults and children during typical activities with both nasal and oral inhalation, that may be used in the design of experimental studies and interpretation of health effects evidence. METHODS: We estimated the fraction of inhaled particles (0.5-20 μm aerodynamic diameter) penetrating beyond the larynx (based on experimental data) and ciliated airways (based on a mathematical model) for an adult male, adult female, and a 10 yr old child during typical daily activities and breathing patterns. RESULTS: Our estimates show less penetration of coarse particulate matter into the thoracic and gas exchange regions of the respiratory tract than current size-selective criteria. Of the parameters we evaluated, particle penetration into the lower respiratory tract was most dependent on route of breathing. For typical activity levels and breathing habits, we estimated a 50% cut-size for the thoracic fraction at an aerodynamic diameter of around 3 μm in adults and 5 μm in children, whereas current ambient and occupational criteria suggest a 50% cut-size of 10 μm. CONCLUSIONS: By design, current size-selective sample criteria overestimate the mass of particles generally expected to penetrate into the lower respiratory tract to provide protection for individuals who may breathe orally. We provide estimates of thoracic and respirable fractions for a variety of breathing habits and activities that may benefit the design of experimental studies and interpretation of particle size-specific health effects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-8977-10-12

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Thoracic particulate mass fraction criteria (relative to total airborne particles) for size-selective sampling. Individual data points are observed human head penetration efficiency during oral inhalation for an inspiratory flow rate of 43.5 L/min, i.e., light exercise [5-7]. As stated by ACGIH [3], the sampling criterion is offset to the right of experimental data to overestimate the amount of exposure to the lower respiratory tract, i.e., the lungs, and correspondingly to provide a greater level of protection for exposed workers. From ACGIH®, Particle Size-Selective Sampling in the Workplace, Report of the ACGIH® Technical Committee on Air Sampling Procedures. Copyright 1985. Reprinted with permission. Courtesy: Dr. Otto G. Raabe.
Figure 1 Thoracic particulate mass fraction criteria (relative to total airborne particles) for size-selective sampling. Individual data points are observed human head penetration efficiency during oral inhalation for an inspiratory flow rate of 43.5 L/min, i.e., light exercise [5-7]. As stated by ACGIH [3], the sampling criterion is offset to the right of experimental data to overestimate the amount of exposure to the lower respiratory tract, i.e., the lungs, and correspondingly to provide a greater level of protection for exposed workers. From ACGIH®, Particle Size-Selective Sampling in the Workplace, Report of the ACGIH® Technical Committee on Air Sampling Procedures. Copyright 1985. Reprinted with permission. Courtesy: Dr. Otto G. Raabe.CC BY · PubMed Central
Figure 2 Thoracic fraction, i.e., particle penetration through the extrathoracic region, P(ET), as a function of breathing route. Penetration data are with respect to particle diameter as a function of the fraction of air inhaled through the mouth (Fm) in an adult male engaged in light exercise relative to particles entering the respiratory tract. Curves are for the Fm of 0.00, 0.25, 0.50, 0.75, and 1.00 as indicated on the figure. Horizontal red line highlights 50% penetration.
Figure 2 Thoracic fraction, i.e., particle penetration through the extrathoracic region, P(ET), as a function of breathing route. Penetration data are with respect to particle diameter as a function of the fraction of air inhaled through the mouth (Fm) in an adult male engaged in light exercise relative to particles entering the respiratory tract. Curves are for the Fm of 0.00, 0.25, 0.50, 0.75, and 1.00 as indicated on the figure. Horizontal red line highlights 50% penetration.CC BY · PubMed Central
Figure 3 Respirable fraction, i.e., particle penetration through the tracheobronchial region, P(TB), as a function of breathing route. Penetration data are with respect to particle diameter as a function of the fraction of air inhaled through the mouth (Fm) in an adult male engaged in light exercise relative to particles entering the respiratory tract. Curves are for the Fm of 0.00, 0.25, 0.50, 0.75, and 1.00 as indicated on the figure. Horizontal red line highlights 50% penetration.
Figure 3 Respirable fraction, i.e., particle penetration through the tracheobronchial region, P(TB), as a function of breathing route. Penetration data are with respect to particle diameter as a function of the fraction of air inhaled through the mouth (Fm) in an adult male engaged in light exercise relative to particles entering the respiratory tract. Curves are for the Fm of 0.00, 0.25, 0.50, 0.75, and 1.00 as indicated on the figure. Horizontal red line highlights 50% penetration.CC BY · PubMed Central
Figure 4 Thoracic fraction, i.e., particle penetration through the extrathoracic region, P(ET)avg, in adults and a 10 yr-old child. Data are daily averaged values for a median activity level, gradual augmenter breathing habit, and uncorrected for particle inhalability. Child-A and child-B are for a scaling factor of 1.0 and 1.26 in Equations 2 and 3, respectively. Horizontal red line highlights 50% penetration which occurs at 3.1 μm (adult female), 3.4 μm (adult male), 4.1 μm (child-B), and 5.1 μm (child-A).
Figure 4 Thoracic fraction, i.e., particle penetration through the extrathoracic region, P(ET)avg, in adults and a 10 yr-old child. Data are daily averaged values for a median activity level, gradual augmenter breathing habit, and uncorrected for particle inhalability. Child-A and child-B are for a scaling factor of 1.0 and 1.26 in Equations 2 and 3, respectively. Horizontal red line highlights 50% penetration which occurs at 3.1 μm (adult female), 3.4 μm (adult male), 4.1 μm (child-B), and 5.1 μm (child-A).CC BY · PubMed Central
Figure 5 Respirable fraction, i.e., particle penetration through the tracheobronchial region, P(TB)avg, in adults and a 10 yr-old child. Data are daily averaged values for a median activity level, gradual augmenter breathing habit, and uncorrected for particle inhalability. Child-A and child-B are for a scaling factor of 1.0 and 1.26 in Equations 2 and 3, respectively. Horizontal red line highlights 50% penetration which occurs at 2.7 μm (adult female), 3.1 μm (adult male), 3.6 μm (child-B), and 4.4 μm (child-A).
Figure 5 Respirable fraction, i.e., particle penetration through the tracheobronchial region, P(TB)avg, in adults and a 10 yr-old child. Data are daily averaged values for a median activity level, gradual augmenter breathing habit, and uncorrected for particle inhalability. Child-A and child-B are for a scaling factor of 1.0 and 1.26 in Equations 2 and 3, respectively. Horizontal red line highlights 50% penetration which occurs at 2.7 μm (adult female), 3.1 μm (adult male), 3.6 μm (child-B), and 4.4 μm (child-A).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 475

Metadata

Authors
Brown, J. S., Gordon, T., Price, O., & Asgharian, B.
Affiliations
  • Environmental Protection Agency (US)
  • NYU Langone Health (US)
  • Applied Research Associates (United States) (US)
Corresponding author
Brown, James S
Venue
Particle and Fibre Toxicology
Published
2013
Volume
10
Issue
1
Pages
12
ISSN
1743-8977 (ISSN-L)
OpenAlex
W2137087705
Cited by
474
References
24
Citations by year
2026: 32 · 2025: 41 · 2024: 37 · 2023: 51 · 2022: 66 · 2021: 64 · 2020: 39 · 2019: 37 · 2018: 39 · 2017: 30 · 2016: 15 · 2015: 13 · 2014: 9 · 2013: 1
FWCI
9.31
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Particle and Fibre Toxicology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • U.S. Environmental Protection Agency
  • Oak Ridge Institute for Science and Education
  • National Center For Environmental Assessment
  • National Institute for Occupational Safety and Health
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
Keywords
respirable fraction, particle penetration, respiratory tract deposition, cut size, oral inhalation, nasal inhalation, breathing pattern, children, coarse particles, human health risk assessment
MeSH terms
Activities of Daily Living, Adult, Aerosols, Age Factors, Air Pollutants, Body Burden, Child, Female, Humans, Male, Models, Biological, Terminology as Topic, Particle Size, Respiration, Respiratory System, Risk Factors, Sex Factors, Toxicology, Linear Models, Risk Assessment, Inhalation Exposure, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thoracic and respirable particle definitions for human health risk assessment. https://app.cochat.ai/papers/10.1186/1743-8977-10-12
The paper
Brown, J. S., Gordon, T., Price, O., & Asgharian, B. (2013). Thoracic and respirable particle definitions for human health risk assessment. Particle and Fibre Toxicology. https://doi.org/10.1186/1743-8977-10-12

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.