Respirator Cartridge Filter Efficiency under Cyclic- and Steady-Flow Conditions
The DOI matches its Crossref record.
Abstract
Respirator filter cartridges are routinely tested under steady-flow conditions to provide a basis for predicting their future performance under cyclic-flow breathing conditions. Tests were performed to define aerosol penetration through respirator filter cartridges under both cyclic and steady flow. A breathing pump was used to simulate different human breathing patterns. Steady-flow conditions were identical to those recommended by the U.S. Bureau of Mines for permissibility tests of respiratory protective devices. Solid monodisperse polystyrene latex aerosols ranging from 0.176 to 2.02 μm in size and liquid monodisperse 0.3-μm dioctyl phthalate were used as the test aerosols. Sampling during cyclic flow was performed without altering the flow pattern through the respirator cartridge. Steady- and cyclic-flow experimental data are compared as a function of aerosol size, breathing pattern, and aerosol type. Theoretical steady-flow aerosol penetration is compared to experimental cyclic-flow data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Still being checked.
Research works printed but not linked: 3
- [2]2. "Respiratory Protective Devices; Tests for Permissibility," Department of the Interior, Bureau of Mines, Federal Register, 36, No. 47 (Wed. March 10, 1971), pp. 4652-4680.
- [5]5. T. J. Rowland, "Study of Aerosol Filtration Characteristics Under Steady and Pulsating Flow Conditions," Master of Science Thesis, The University of Arkansas, Little Rock, Arkansas (1970).
- [11]11. K. T. Whitby and B. Y. H. Liu, Aerosol Science, C. N. Davies, Ed. (Academic Press, New York, 1966), Chap. III.
Cited by
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
“,(13) measured the penetration of monodisperse polystyrene latex spheres (PSL) (0.”
BackgroundResultMahdavi, A., Haghighat, F., Bahloul, A., Brochot, C., & Ostiguy, C. (2015) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mev005 · Cited by 54
Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger
Johnson, B., Martin, D. D., & Resnick, I. G. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.6.2184-2186.1994 · Cited by 44
Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep062 · Cited by 42
He, X., Grinshpun, S. A., Reponen, T. A., McKay, R. T., Bergman, M. S., & Zhuang, Z. (2013) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/met053 · Cited by 42
Evaluation of N95 Filtering Facepiece Respirator Efficiency with Cyclic and Constant Flows
Bahloul, A., Mahdavi, A., Haghighat, F., & Ostiguy, C. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.877590 · Cited by 37
Measurement of Protection Factor of Respiratory Protective Devices Toward Nanoparticles
Brochot, C., Michielsen, N., Chazelet, S., & Thomas, D. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes032 · Cited by 28
Mahdavi, A. (2013) · Spectrum Research Repository (Concordia University) · Cited by 22
Haruta, H., Honda, T., Eninger, R. M., Reponen, T. A., McKay, R. T., & Grinshpun, S. A. (2008) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167201 · Cited by 22
Lab., N. M. (. L. A. S., Hyatt, E. C., Pritchard, J., & Held, B. J. (1974) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/4303682 · Cited by 14
Zhu, J., He, X., Guffey, S. E., Wang, L., Wang, H., & Cheng, J. (2019) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxz086 · Cited by 13
Filtration performance of glass fibrous air filter media under sinusoidal flow condition
Zhou, B., Xu, Y., Chen, L., Tronville, P. M., Yu, Y.-L., & Chen, L. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107182 · Cited by 13
Ramirez, J. A., Nonnenmann, M. W., Fethke, N. B., O'Shaughnessy, P., Peters, T. M., & Anthony, T. R. (2015) · doi:10.17077/etd.wfvehzie · Cited by 12
Advanced testing method to evaluate the performance of respirator filter media
Wang, Q., Golshahi, L., & Chen, D. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1177647 · Cited by 8
Respirator Filtration Efficiency Testing
Moyer, E. S. (1986) · doi:10.1520/stp42088s · Cited by 7
The Effect of Flow Pattern on Collection Efficiency of Respirator Filters
Wang, A., Richardson, A. W., & Hofacre, K. C. (2012) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166946 · Cited by 7
Filtration des nanoparticules : application aux appareils de protection respiratoire
Brochot, C. (2012) · theses.fr (ABES) · doi:10.70675/24d59aa4zdebfz443cz92ebzad50d4239238 · Cited by 6
Review: Protection Factors of Respirators With Special Reference to Dust Respirators
Brown, R. (1992) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.168976 · Cited by 7
Tanaka, S., Tanaka, M., Kimura, K., NOZAKI, K., & Seki, Y. (1996) · Industrial Health · doi:10.2486/indhealth.34.227 · Cited by 6
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T. A., McKay, R. T., & Lee, S.-A. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877051 · Cited by 5
Evaluation of Respirator Filter Media under Inhalation-only Conditions
Wang, Q., Golshahi, L., & Chen, D. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.08.0375 · Cited by 4
Filter media performance under the oscillating flow condition
Wang, P., & Chen, D. (2019) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2019.03.004 · Cited by 3
Zhu, J., Li, X., Jing, P., He, X., Wang, L., Zheng, L., Sun, H., Yang, J., & Liu, J. (2022) · Aerosol Science and Technology · doi:10.1080/02786826.2022.2095893 · Cited by 3
FILTER PERFORMANCE UNDER SIMULATED REAL-WORLD CONDITIONS
Wang, Q. (2016) · VCU Scholars Compass (Virginia Commonwealth University) · doi:10.25772/cr0p-td41 · Cited by 2
MURATA, M., Ikezawa, Y., & Yoshida, Y. (1976) · Japanese Journal of Health Physics · doi:10.5453/jhps.11.51 · Cited by 2
Bahloul, A., Haghighat, F., Mostofi, R., Mahdavi, A., & Ostiguy, C. (2016) · PhareSST · Cited by 1
Bahloul, A., Haghighat, F., Mostofi, R., Mahdavi, A., & Ostiguy, C. (2016) · PhareSST · doi:10.70010/utvy9955
Efficiency evaluation of N95 FFRs under cyclic and constant flows
Bahloul, A., Haghighat, F., Mostofi, R., Mahdavi, A., & Ostiguy, C. (2016) · PhareSST · doi:10.70010/dxpt6338
He, X. (2013) · OhioLink ETD Center (Ohio Library and Information Network)
Development of a Filtering Respirator with a Real-Time Monitoring Device for Pressure Drop
Cheberiachko, Y., Radchuk, D., Чеберячко, С. І., Славінський, Д. В., & Kravchenko, B. (2026) · Journal of Scientific Papers Social development & Security · doi:10.33445/sds.2026.16.1.16
Metadata
- Authors
- STAFFORD, R. G., ETTINGER, H. J., & ROWLAND, T. J.
- Affiliations
- Los Alamos National Laboratory (US)
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1973-05
- Volume
- 34
- Issue
- 5
- Pages
- 182-192
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W1984166972
- Cited by
- 20
- References
- 0
- Citations by year
- 2022: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 1
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Industrial and Mining Safety
- Keywords
- aerosol penetration, breathing pattern, respiratory protective equipment, monodisperse aerosols, dioctyl phthalate, aerosol particle size
- MeSH terms
- Aerosols, Efficiency, Filtration, Humans, Latex, Microspheres, Models, Biological, Motion, Particle Size, Phthalic Acids, Polystyrenes, Respiration, Ventilators, Mechanical, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.