Collection of Silica and Asbestos Aerosols by Respirators at Steady and Cyclic Flow
The DOI matches its Crossref record.
Abstract
Air purifying dust/mist respirators are presently tested using a silica aerosol under conditions of steady flow. In experiments, the predictive validity of such tests was evaluated by testing respirators using silica and asbestos aerosols under conditions of both steady and cyclic flow. Silica penetration at steady flow was reasonably predictive of silica penetration under cyclic flow. However, asbestos penetration under cyclic flow was not predicted well by penetration of either silica or asbestos at steady flow. Furthermore, the potential for exhalation valve failure under cyclic flow was identified. Current NIOSH protocols for evaluating respirator performance should be reconsidered in light of these findings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Still being checked.
Cited by
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
“This is consistent with previous research that has shown constant flow equivalent to the MIF or Minute flow results in a lower penetration than the corresponding cyclic flow.(13,14) Although the mean differences were not exactly the same, the 0.”
BackgroundResultLarge Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep062 · Cited by 42
Metadata
- Authors
- BROSSEAU, L. M., ELLENBECKER, M. J., & EVANS, J. S.
- Affiliations
- Harvard University (US)
- University of Massachusetts Lowell (US)
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1990-08
- Volume
- 51
- Issue
- 8
- Pages
- 420-426
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2041152848
- Cited by
- 18
- References
- 0
- Citations by year
- 2023: 1 · 2021: 2 · 2018: 1 · 2017: 1 · 2015: 1 · 2014: 2 · 2013: 1 · 2012: 1
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (5 R01 OH02154-02, 5T15 OH07096)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Industrial and Mining Safety
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Keywords
- air-purifying respirators, aerosol penetration, cyclic flow, steady flow, predictive validity
- MeSH terms
- Aerosols, Asbestos, Dust, Equipment Failure, Humans, Humidity, Materials Testing, Predictive Value of Tests, Protective Devices, Respiratory Protective Devices, Silicon Dioxide
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Collection of Silica and Asbestos Aerosols by Respirators at Steady and Cyclic Flow. https://app.cochat.ai/papers/10.1080/15298669091369880
- The paper
- BROSSEAU, L. M., ELLENBECKER, M. J., & EVANS, J. S. (1990). Collection of Silica and Asbestos Aerosols by Respirators at Steady and Cyclic Flow. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298669091369880
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.