CoChat

Preconcentration and Determination of Chlorophenols in Wastewater with Dispersive Liquid–Liquid Microextraction Using Hydrophobic Deep Eutectic Solvents

An, Yena, Ma, Wanwan, Row, Kyung Ho · 2020 · Analytical Letters
Cited by 47

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Hydrophobic deep eutectic solvents (DESs) were synthesized and developed for the preconcentration of three chlorophenols from wastewater by dispersive liquid–liquid microextraction (DLLME). The analyte concentrations were determined by high-performance liquid chromatography (HPLC). The hydrophobic DESs were prepared with the combination of hydrogen bond donors of decanoic acid or octanoic acid with different hydrogen bond acceptors of quaternary ammonium salts of tetrabutylammonium chloride, tetraoctylammonium chloride, methyltrioctylammonium chloride, and tetraheptylammonium chloride). Following the study of the stability and characterization by Fourier transform infrared spectroscopy, the hydrophobic DESs were developed as extractants and employed for the removal of 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), and 2,4,6-trichlorophenol (2,4,6-TCP) from wastewater. Using hydrophobic DESs as the microextraction solvents, several key parameters were optimized, including the type and volume of the hydrophobic DES, pH, and time of the extraction procedure. Under the optimized conditions, good recoveries from 90.8% to 93.0% were obtained for the three chlorophenols. The limits of detection were less than 0.05 µg/mL with relative standard deviations between 1.8% and 3.1%. The method was applied for the isolation and determination of synthetic chlorophenols in wastewater.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00032719.2019.1646754

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 14

  1. 10.1016/j.jchromb.2018.06.049 · DOI · Paper page
  2. 10.1016/j.chroma.2017.12.059 · DOI · Paper page
  3. 10.1016/j.jenvman.2019.04.004 · DOI · Paper page
  4. 10.1080/00032719.2018.1467434 · DOI
  5. 10.1016/j.talanta.2018.10.096 · doi:10.1016/j.talanta.2018.10.096
  6. 10.1016/j.trac.2017.08.014 · DOI
  7. 10.1002/jssc.201600941 · DOI
  8. 10.1016/j.chroma.2018.01.013 · DOI
  9. 10.1016/j.biotechadv.2016.11.006 · DOI · Paper page
  10. 10.1007/s00216-018-1346-6 · DOI
  11. 10.1007/s00216-017-0798-4 · DOI
  12. 10.1016/j.foodchem.2017.10.115 · DOI
  13. 10.1016/j.foodchem.2019.124962 · DOI
  14. 10.1146/annurev-environ-102016-060700 · DOI · Paper page

Cited by

See all 47

Metadata

Authors
An, Y., Ma, W., & Row, K. H.
Venue
Analytical Letters
Published
2019-07-27
Volume
53
Issue
2
Pages
262-272
ISSN
  • 0003-2719 (ISSN-L)
  • 1532-236X
OpenAlex
W2964637119
Cited by
47
References
8
FWCI
3.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preconcentration and Determination of Chlorophenols in Wastewater with Dispersive Liquid–Liquid Microextraction Using Hydrophobic Deep Eutectic Solvents. https://app.cochat.ai/papers/10.1080/00032719.2019.1646754
The paper
An, Y., Ma, W., & Row, K. H. (2020). Preconcentration and Determination of Chlorophenols in Wastewater with Dispersive Liquid–Liquid Microextraction Using Hydrophobic Deep Eutectic Solvents. Analytical Letters. https://doi.org/10.1080/00032719.2019.1646754

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.