The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Determination of Trace Amounts of Cobalt in Natural Water Samples as 4-(2-Thiazolylazo) Recorcinol Complex After Adsorptive Preconcentration
Abstract
A chromatographic method has been established for the determination of trace amounts of cobalt by preconcentration on Amberlite XAD-16 resin as cobalt/4-(2-Thiazolylazo) resorcinol (TAR) complexes. The conditions (e.g. pH, resin amounts, matrix ions) affecting the recovery of cobalt from aqueous solution were studied. The method has been employed for the determination of cobalt in natural water samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The sample volume is an important factor for obtaining a high preconcentration factor.
“The sample volume is an important factor for obtaining a high preconcentration factor [51,52,53,54,55,56,57,58].”
From Deep Eutectic Solvent-Based Microextraction of Lead(II) Traces from Water and Aqueous Extracts before FAAS Measurements (2020) · cites this paper as [53]
Citations
Cites
Trace Elements in Human and Animal Nutrition
UNDERWOOD, E. J. (1963) · Soil Science · doi:10.1097/00010694-196304000-00029 · Cited by 4,511
Trace Element Contamination of the Environment
(1977) · Elsevier eBooks · doi:10.1016/b978-0-444-41570-7.x5001-3 · Cited by 217
Soylak, M., Şahin, U., & Elçı, L. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00603-6 · Cited by 109
Self-citationTrace Elements in Human and Animal Nutrition, 5th ed.
Prohaska, J. R. (1989) · Journal of Nutrition · doi:10.1093/jn/119.5.831 · Cited by 74
Soylak, M., Elçı, L., & Doğan, M. (1993) · Analytical Letters · doi:10.1080/00032719308017446 · Cited by 71
Self-citationPreconcentration of cobalt with N-(dithiocarboxy)sarcosine and amberlite xad-4 resin
Sakai, Y., & Mori, N. (1986) · Talanta · doi:10.1016/0039-9140(86)80033-9 · Cited by 43
Compañó, R., Ferrer, R., Guiteras, J., et al. (1994) · The Analyst · doi:10.1039/an9941901225 · Cited by 43
Isshiki, K., & Nakayama, E. (1987) · Analytical Chemistry · doi:10.1021/ac00129a015 · Cited by 41
Untersuchungen zur adsorptiven Anreicherung von Elementspuren an Adsorberharzen
Yang, X. G., & Jackwerth, E. (1987) · Fresenius Zeitschrift für Analytische Chemie · doi:10.1007/bf00469814 · Cited by 25
Untersuchungen zur adsorptiven Anreicherung von Elementspuren an Adsorberharzen
Jackwerth, E., Yang, X. G., & Xu, C. (1989) · Fresenius Zeitschrift für Analytische Chemie · doi:10.1007/bf00483569 · Cited by 18
Yebra-Biurrun, M. C., Bermejo, A. M., & Bermejo‐Barrera, P. (1991) · The Analyst · doi:10.1039/an9911601033 · Cited by 15
Satake, M., Nagahiro, T., & Bal Krishan, P. U. R. I. (1993) · The Analyst · doi:10.1039/an9931800085 · Cited by 12
Zhang, L., & Terada, K. (1994) · Analytical Sciences · doi:10.2116/analsci.10.161 · Cited by 6
Flagged first, then by citations
Research works printed but not linked: 2
- Soylak M., 1996, Trace Elem. & Electroyt., 13, 130
- Soylak M., 1995, Fresenius Envir. Bull., 4, 35
Cited by
Sorted by citations
Arain, M. B., Yilmaz, E., & Soylak, M. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2016.10.005 · Cited by 168
Self-citationHabila, M. A., AlMasoud, N., Alomar, T. S., AlOthman, Z. A., Yilmaz, E., & Soylak, M. (2020) · Molecules · doi:10.3390/molecules25204794 · Cited by 38
Self-citationAl-Nidawi, M., Uzcan, F., Alshana, U., & Soylak, M. (2024) · Analytical Letters · doi:10.1080/00032719.2023.2202915 · Cited by 18
Self-citation
Metadata
- Authors
- Soylak, M., Elci, L., & Dogan, M.
- Affiliations
- Erciyes University (TR)
- ORCID
- Soylak, M.
- Venue
- Analytical Letters
- Publisher
- Informa UK Limited
- Published
- 1997-02
- Volume
- 30
- Issue
- 3
- Pages
- 623-631
- ISSN
- 0003-2719 (ISSN-L)
- 1532-236X
- OpenAlex
- W2101716323
- Cited by
- 121
- References
- 13
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 14 · 2022: 6 · 2021: 1 · 2020: 5 · 2019: 6 · 2018: 4 · 2017: 3 · 2016: 5 · 2015: 5 · 2014: 4 · 2013: 4 · 2012: 13
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Letters (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
- Keywords
- cobalt determination, trace metal analysis, natural waters, adsorptive preconcentration, 4-(2-thiazolylazo)resorcinol, metal complexation, chromatographic determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review