Trace Enrichment and Atomic Absorption Spectrometric Determination of Lead, Copper, Cadmium and Nickel in Drinking Water Samples by Use of an Activated Carbon Column
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A simple method for atomic absorption spectrometric determination of lead, copper, cadmium and nickel in drinking water samples after preconcentration by sorbing 1-(2-pyridylazo) 2-naphthol (PAN) complex of these metals on an activated carbon column has been established. The metal/PAN complexes were quantitatively retained on the activated carbon in the pH range 6-8. Metals retained on the activated carbon column were completely eluted with 2M HCl in acetone. This method was applied to the determination of lead, copper, cadmium and nickel in drinking water samples and good results were obtained (Recoveries >95%, relative standard deviations <7%, relative error <3%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soylak, M., Elci, L., & Dogan, M. (1997) · Analytical Letters · doi:10.1080/00032719708001806 · Cited by 121
Self-citation
Cited by
Ghaedi, M., Ahmadi, F., & Shokrollahi, A. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.08.012 · Cited by 598
Chen, J., & Teo, K. C. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01367-8 · Cited by 355
Narin, I. (2000) · Talanta · doi:10.1016/s0039-9140(00)00468-9 · Cited by 251
Self-citationSoylak, M., & Yilmaz, E. (2015) · Analytical Letters · doi:10.1080/00032719.2014.949732 · Cited by 42
“Matrix Effects The influence of potential interfering ions (Soylak, Elci, and Dogan 1996; Soylak, Narin, and Dogan 1997) on the suggested microextraction procedure was evaluated.”
BackgroundSelf-citationAlothman, Z. A., Al-Shaalan, N. H., Habila, M. A., Unsal, Y. E., Tuzen, M., & Soylak, M. (2015) · Environmental Monitoring and Assessment · doi:10.1007/s10661-014-4160-4 · Cited by 22
“To obtain a high preconcentration factor, the volume of the sample is a critical factor (Soylak et al. 1997; Zhang et al. 2010; Soylak and Elci 2000; Liang et al. 2001).”
BackgroundSelf-citation
Metadata
- Authors
- Soylak, M., Narin, I., & Dogan, M.
- Venue
- Analytical Letters
- Publisher
- Informa UK Limited
- Published
- 1997-12
- Volume
- 30
- Issue
- 15
- Pages
- 2801-2810
- ISSN
- 0003-2719 (ISSN-L)
- 1532-236X
- OpenAlex
- W2035891448
- Cited by
- 110
- References
- 1
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trace Enrichment and Atomic Absorption Spectrometric Determination of Lead, Copper, Cadmium and Nickel in Drinking Water Samples by Use of an Activated Carbon Column. https://app.cochat.ai/papers/10.1080/00032719708001823
- The paper
- Soylak, M., Narin, I., & Dogan, M. (1997). Trace Enrichment and Atomic Absorption Spectrometric Determination of Lead, Copper, Cadmium and Nickel in Drinking Water Samples by Use of an Activated Carbon Column. Analytical Letters. https://doi.org/10.1080/00032719708001823
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.